Pinki Anand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pinki Anand has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Azahar Ali
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory , Dr. K. S. Krishnan Marg, New Delhi, Delhi 110012, India
1 shared publication - Bansi Dhar Malhotra
Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi, India
1 shared publication Jasmine Isar
Department of Microbiology, University of Delhi South Campus, Benito Juarez Road, New Delhi, 110021, India
1 shared publication- Rajendra Kumar Saxena
Department of Microbiology, University of Delhi South Campus, New Delhi 110021, India
1 shared publication - Rajendra Kumar Saxena
Department of Microbiology, University of Delhi, South Campus, New Delhi, 110 021 India
1 shared publication - Rajendra Kumar Saxena
University of Delhi South Campus
1 shared publication
Latest Publications
- 6 September 2013
- Published by Wiley in Biotechnology Journal
- Vol. 8 (11) , 1267-1279
Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics
There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics‐integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro‐ to nano‐liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point‐of‐care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic‐integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry.
- 6 September 2013
- Published by Wiley in Biotechnology Journal
- Vol. 8 (11) , 1267-1279
Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics
There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics‐integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro‐ to nano‐liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point‐of‐care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic‐integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry.
- 1 November 2012
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 39 (11) , 1713-1718
A novel thin-layer chromatography method to screen 1,3-propanediol producers
To date, there is no established protocol for the screening of 1,3-propanediol producers. The proposed method has a wide applicability to harness the commercial potential of microorganisms which produce 1,3-propanediol as the end product. Glycerol fermentation broth of 50 bacteria spotted on thin-layer chromatography plates and run by appropriate solvent systems followed by colour development using vanillin reagent gave different coloured spots with most of the compounds present in the fermentation broth. The appearance of a purple-coloured spot of 1,3-propanediol with a retention factor (R f) of 0.62 forms the basis for the selection of 1,3-propanediol producers. Apart from being a rapid detection system the proposed method is pH independent and its authenticity was reconfirmed by HPLC.
- 1 November 2012
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 39 (11) , 1713-1718
A novel thin-layer chromatography method to screen 1,3-propanediol producers
To date, there is no established protocol for the screening of 1,3-propanediol producers. The proposed method has a wide applicability to harness the commercial potential of microorganisms which produce 1,3-propanediol as the end product. Glycerol fermentation broth of 50 bacteria spotted on thin-layer chromatography plates and run by appropriate solvent systems followed by colour development using vanillin reagent gave different coloured spots with most of the compounds present in the fermentation broth. The appearance of a purple-coloured spot of 1,3-propanediol with a retention factor (R f) of 0.62 forms the basis for the selection of 1,3-propanediol producers. Apart from being a rapid detection system the proposed method is pH independent and its authenticity was reconfirmed by HPLC.
- 1 March 2011
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 90 (4) , 1267-1276
A novel downstream process for 1,3-propanediol from glycerol-based fermentation
In this paper, a downstream process for purification of 1,3-propanediol from glycerol-based fermentation broth was investigated. The purification of 1,3-propanediol from fermentation broth was achieved by a process combining microfiltration, charcoal treatment, vacuum distillation, and silica gel chromatography. The broth was first filtered through hollow fiber cartridge, wherein 98.7% of biomass was removed. Soluble proteins and other color impurities in the broth were removed by the use of activated charcoal at optimal concentration of 30 g l−1 where the soluble proteins in the broth decreased to 0.1 g l−1 (96.0% protein loss). The obtained broth when concentrated by vacuum distillation resulted in the crystallization of inorganic salts. Subsequently, 1,3-propanediol was purified by gradient chromatography using silica gel as a stationary phase and mixture of chloroform and methanol as a mobile phase. Finally, with the optimal flow rate of 10 ml min−1 and loading amount of 80 ml, the yield of 1,3-propanediol achieved was 89%. The overall yield of 1,3-propanediol using the proposed procedure was 75.47%. The developed method was found to be a simple, rapid, and efficient procedure for the purification of 1,3-propanediol from fermentation broth.
- 1 March 2011
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 90 (4) , 1267-1276
A novel downstream process for 1,3-propanediol from glycerol-based fermentation
In this paper, a downstream process for purification of 1,3-propanediol from glycerol-based fermentation broth was investigated. The purification of 1,3-propanediol from fermentation broth was achieved by a process combining microfiltration, charcoal treatment, vacuum distillation, and silica gel chromatography. The broth was first filtered through hollow fiber cartridge, wherein 98.7% of biomass was removed. Soluble proteins and other color impurities in the broth were removed by the use of activated charcoal at optimal concentration of 30 g l−1 where the soluble proteins in the broth decreased to 0.1 g l−1 (96.0% protein loss). The obtained broth when concentrated by vacuum distillation resulted in the crystallization of inorganic salts. Subsequently, 1,3-propanediol was purified by gradient chromatography using silica gel as a stationary phase and mixture of chloroform and methanol as a mobile phase. Finally, with the optimal flow rate of 10 ml min−1 and loading amount of 80 ml, the yield of 1,3-propanediol achieved was 89%. The overall yield of 1,3-propanediol using the proposed procedure was 75.47%. The developed method was found to be a simple, rapid, and efficient procedure for the purification of 1,3-propanediol from fermentation broth.
- Top Cited Papers
- 1 November 2009
- Published by Elsevier in Biotechnology Advances
- Vol. 27 (6) , 895-913
Microbial production of 1,3-propanediol: Recent developments and emerging opportunities
- 1 November 2009
- Published by Elsevier in Biotechnology Advances
- Vol. 27 (6) , 895-913
Top Cited PapersMicrobial production of 1,3-propanediol: Recent developments and emerging opportunities