Pin-Hua Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pin-Hua Xie has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Wen-Qing Liu
24 shared publications- Fuqi Si
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, Anhui, China
16 shared publications Ke Dou
10 shared publications- Min Qin
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, China
10 shared publications Wenqing Liu
7 shared publications- Jianguo Liu
Hefei Institutes of Physical Science (Hefei, China)
6 shared publications
Latest Publications
- 1 February 2016
- Vol. 36 (2) , 466-70
[An Incoherent Broadband Optical Cavity Spectroscopy for Measuring Weak Absorption Cross Section of Sulfur Dioxide].
As a highly sensitive detection technology, incoherent broadband cavity enhanced absorption spectroscopy (IBBCEAS) have successfully measured a variety of trace gases. According to the principle of cavity enhanced absorption spectroscopy, if the accurate concentration of the target gas, the curve of the mirror reflectance, effective absorption path length, the light intensity of the absorbing gas and non-absorbing gas are known, the absorption cross section of the absorption gas can be measured. The accurate measurements of absorption cross section are necessary for satellite retrievals of atmospheric trace gases and the atmospheric research. This paper describes an incoherent broadband cavity enhanced absorption spectroscopy(IBBCEAS) instrument with 365 nm LED as the light source for measuring absorption cross section of SO₂ from 357 to 385 nm which is arising from the spin-forbidden a ³B₁--X¹A₁ transition. In comparison to the literature absorption cross section of SO₂, and correlation coefficient r is 0.997 3. The result shows the potential of the IBBCEAS system for measuring weak absorption cross section.
- 1 February 2016
- Vol. 36 (2) , 466-70
[An Incoherent Broadband Optical Cavity Spectroscopy for Measuring Weak Absorption Cross Section of Sulfur Dioxide].
As a highly sensitive detection technology, incoherent broadband cavity enhanced absorption spectroscopy (IBBCEAS) have successfully measured a variety of trace gases. According to the principle of cavity enhanced absorption spectroscopy, if the accurate concentration of the target gas, the curve of the mirror reflectance, effective absorption path length, the light intensity of the absorbing gas and non-absorbing gas are known, the absorption cross section of the absorption gas can be measured. The accurate measurements of absorption cross section are necessary for satellite retrievals of atmospheric trace gases and the atmospheric research. This paper describes an incoherent broadband cavity enhanced absorption spectroscopy(IBBCEAS) instrument with 365 nm LED as the light source for measuring absorption cross section of SO₂ from 357 to 385 nm which is arising from the spin-forbidden a ³B₁--X¹A₁ transition. In comparison to the literature absorption cross section of SO₂, and correlation coefficient r is 0.997 3. The result shows the potential of the IBBCEAS system for measuring weak absorption cross section.
- Open Access
- 1 November 2015
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 166, 23-29
Diode laser cavity ring-down spectroscopy for in situ measurement of NO3 radical in ambient air
- 1 November 2015
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 166, 23-29
Open AccessDiode laser cavity ring-down spectroscopy for in situ measurement of NO3 radical in ambient air
- Open Access
- 21 October 2015
- Published by IntechOpen
A Comprehensive Research of Atmospheric Haze by Optical Remote Sensing in Central China Region (CCR)
- 21 October 2015
- Published by IntechOpen
Open AccessA Comprehensive Research of Atmospheric Haze by Optical Remote Sensing in Central China Region (CCR)
- 1 February 2013
- Vol. 33 (2) , 444-7
[Measurement of atmospheric NO3 radical with long path differential optical absorption spectroscopy based on red light emitting diodes].
Nitrate radical (NO3) is the most important oxidant in the tropospheric nighttime chemistry. Due to its high reactivity and low atmospheric concentrations, modern red light emitting diodes (LEDs) was proposed as light source in long path differential optical absorption spectroscopy (LP-DOAS) to measure NO3 radical in the atmosphere. The spectral properties of Luxeon LXHL-MD1D LEDs were analyzed in the present paper. The principle of LEDs-DOAS system to measure nitrate radical was studied in this paper. The experimental setup and retrieval method of NO3 radical were discussed in this paper. The retrieved example of NO3 was given and the time series of NO3 concentrations was performed for a week. The results showed that the detection limits of LEDs-DOAS system were 12 ppt for atmospheric NO3 radical when the optical path of LEDs-DOAS system was 2.8 km.
- 1 February 2013
- Vol. 33 (2) , 444-7
[Measurement of atmospheric NO3 radical with long path differential optical absorption spectroscopy based on red light emitting diodes].
Nitrate radical (NO3) is the most important oxidant in the tropospheric nighttime chemistry. Due to its high reactivity and low atmospheric concentrations, modern red light emitting diodes (LEDs) was proposed as light source in long path differential optical absorption spectroscopy (LP-DOAS) to measure NO3 radical in the atmosphere. The spectral properties of Luxeon LXHL-MD1D LEDs were analyzed in the present paper. The principle of LEDs-DOAS system to measure nitrate radical was studied in this paper. The experimental setup and retrieval method of NO3 radical were discussed in this paper. The retrieved example of NO3 was given and the time series of NO3 concentrations was performed for a week. The results showed that the detection limits of LEDs-DOAS system were 12 ppt for atmospheric NO3 radical when the optical path of LEDs-DOAS system was 2.8 km.
- 1 November 2012
- Vol. 32 (11) , 2897-901
[Measurement of OH radicals in flame with XeCl excimer laser].
The present paper describes how to measure OH radicals in the flame of alcohol burner flame by using XeCl excimer laser. The instrument consists of a XeCl excimer laser as light source, a multiple-reflection cell with whole path length of light achieving 2 560 meters, and a double pass high resolution echelle spectrometer with resolution 3.3 pm. This paper describes the reason for using the XeCl excimer laser without spectral etaloning and how to get rid of the water in reactor chamber. The results of the experiment get some absorption peak of OH radicals from 308.145 to 308.175 nm. By choosing the appropriate fit area and fitting, the results contrast with the measure data by using Xe lamp as light source.
- 1 November 2012
- Vol. 32 (11) , 2897-901
[Measurement of OH radicals in flame with XeCl excimer laser].
The present paper describes how to measure OH radicals in the flame of alcohol burner flame by using XeCl excimer laser. The instrument consists of a XeCl excimer laser as light source, a multiple-reflection cell with whole path length of light achieving 2 560 meters, and a double pass high resolution echelle spectrometer with resolution 3.3 pm. This paper describes the reason for using the XeCl excimer laser without spectral etaloning and how to get rid of the water in reactor chamber. The results of the experiment get some absorption peak of OH radicals from 308.145 to 308.175 nm. By choosing the appropriate fit area and fitting, the results contrast with the measure data by using Xe lamp as light source.
- 1 September 2012
- Vol. 32 (9) , 2336-40
[MAX-DOAS measurements of NO2 column densities and vertical distribution at Ny-Alesund, Arctic during summer].
The multi-axis differential optical absorption spectroscopy (MAX-DOAS), one of the remote sensing techniques for trace gases measurements, is sensitive to the lower atmosphere by eliminating the influence of stratosphere retrieved from zenith-sky spectroscopy. Ground-based MAX-DOAS measurements were carried out to observe NO2 at Ny-Alesund, Arctic from 5th Jul to 1st Aug 2011. The differential slant column densities (DSCDs) of NO2 at four off-axis angles showed typical pattern of tropospheric absorbers. Based on the assumption that NO2 was well mixed in 0-1 km of the troposphere, the mean mixing ratio of NO2 during the measurement period was 1.023E11 molec x cm(-3). The fluctuation of NO2 might be related to the fossil fuel combustions and the photochemical reactions. The vertical distribution of NO2 at 0-3 km showed that NO2 was mainly originated from boundary layer of sea surface.
- 1 September 2012
- Vol. 32 (9) , 2336-40
[MAX-DOAS measurements of NO2 column densities and vertical distribution at Ny-Alesund, Arctic during summer].
The multi-axis differential optical absorption spectroscopy (MAX-DOAS), one of the remote sensing techniques for trace gases measurements, is sensitive to the lower atmosphere by eliminating the influence of stratosphere retrieved from zenith-sky spectroscopy. Ground-based MAX-DOAS measurements were carried out to observe NO2 at Ny-Alesund, Arctic from 5th Jul to 1st Aug 2011. The differential slant column densities (DSCDs) of NO2 at four off-axis angles showed typical pattern of tropospheric absorbers. Based on the assumption that NO2 was well mixed in 0-1 km of the troposphere, the mean mixing ratio of NO2 during the measurement period was 1.023E11 molec x cm(-3). The fluctuation of NO2 might be related to the fossil fuel combustions and the photochemical reactions. The vertical distribution of NO2 at 0-3 km showed that NO2 was mainly originated from boundary layer of sea surface.
- 1 April 2012
- Vol. 32 (4) , 893-7
[Retrieval of NO2 total vertical columns by direct-sun differential optical absorption spectroscopy].
An appropriate reference spectrum is essential for the direct-sun differential optical absorption spectroscopy (DS-DOAS). It depends on the real reference spectrum to retrieve the total vertical column density (VCD). The spectrum detected at the time with minimum sun zenith angle under the relative clear atmospheric condition in the measurement period was conventionally selected as the reference spectrum. Because there is still untracked NO2 absorption structure in the reference spectrum, the VCD retrieved based on the above spectrum is actually relative VCD, which results in larger error. To solve this problem, a new method was investigated. A convolution of extraterrestrial high-precision solar Fraunhofer spectrum and the instrumental function of the spectrometer was computed and chosen as the reference spectrum. The error induced by NO2 absorption structure in the reference spectrum was removed. Then the fitting error of slant column density (SCD) retrieved by this method was analyzed. The correlation between the absolute SCD and the differential slant column density (dSCD) was calculated. The result shows that the error of SCD retrieved by this new method is below 1.6 x 10(16) molecules x cm(-2) on March 7, 2011, while the error generated by the normal method is about 4.25 x 10(16) molecules x cm(-2). The new method decreased more than 62% error. In addition, the results throughout the day were compared to the troposphere VCD from MAX-DOAS and they are in good agreement. It indicates that the new method could effectively reduce the VCD error of the common way.
- 1 April 2012
- Vol. 32 (4) , 893-7
[Retrieval of NO2 total vertical columns by direct-sun differential optical absorption spectroscopy].
An appropriate reference spectrum is essential for the direct-sun differential optical absorption spectroscopy (DS-DOAS). It depends on the real reference spectrum to retrieve the total vertical column density (VCD). The spectrum detected at the time with minimum sun zenith angle under the relative clear atmospheric condition in the measurement period was conventionally selected as the reference spectrum. Because there is still untracked NO2 absorption structure in the reference spectrum, the VCD retrieved based on the above spectrum is actually relative VCD, which results in larger error. To solve this problem, a new method was investigated. A convolution of extraterrestrial high-precision solar Fraunhofer spectrum and the instrumental function of the spectrometer was computed and chosen as the reference spectrum. The error induced by NO2 absorption structure in the reference spectrum was removed. Then the fitting error of slant column density (SCD) retrieved by this method was analyzed. The correlation between the absolute SCD and the differential slant column density (dSCD) was calculated. The result shows that the error of SCD retrieved by this new method is below 1.6 x 10(16) molecules x cm(-2) on March 7, 2011, while the error generated by the normal method is about 4.25 x 10(16) molecules x cm(-2). The new method decreased more than 62% error. In addition, the results throughout the day were compared to the troposphere VCD from MAX-DOAS and they are in good agreement. It indicates that the new method could effectively reduce the VCD error of the common way.
- 1 February 2012
- Vol. 32 (2) , 476-80
[Study on the measurement of ambient ammonia in urban area based on open-path DOAS technique].
As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%.
- 1 February 2012
- Vol. 32 (2) , 476-80
[Study on the measurement of ambient ammonia in urban area based on open-path DOAS technique].
As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%.
- 1 February 2012
- Vol. 32 (2) , 558-64
[Comparison of NO2 slant columns between two ground-based MAX-DOAS].
The study of comparison of NO2 SCD between two ground-based multi axis DOAS is introduced. The slant columns of NO2 from JAMASTEC are compared with those of AIOFM during the period from November to 31 December 2009. It says that the more signal to noise ratio is obtained by using the adjusted integral time rather than fixed settings; Two instrument show good accordance in the lower viewing angles, with the correlation coefficient of 0.995, but it becomes bad with higher viewing angles. The low deviation between the two instruments was achieved during the period from 9am to 17pm, the results in the 20 degree direction show best agreement with a deviation of 12%, but in other period the deviation becomes larger. The results in the visible range are better than those in the UV range, the residual in the fit decreases by more than 60%, and the results in the visible range show good agreements with those of AIOFM in the UV range during the whole day.
- 1 February 2012
- Vol. 32 (2) , 558-64
[Comparison of NO2 slant columns between two ground-based MAX-DOAS].
The study of comparison of NO2 SCD between two ground-based multi axis DOAS is introduced. The slant columns of NO2 from JAMASTEC are compared with those of AIOFM during the period from November to 31 December 2009. It says that the more signal to noise ratio is obtained by using the adjusted integral time rather than fixed settings; Two instrument show good accordance in the lower viewing angles, with the correlation coefficient of 0.995, but it becomes bad with higher viewing angles. The low deviation between the two instruments was achieved during the period from 9am to 17pm, the results in the 20 degree direction show best agreement with a deviation of 12%, but in other period the deviation becomes larger. The results in the visible range are better than those in the UV range, the residual in the fit decreases by more than 60%, and the results in the visible range show good agreements with those of AIOFM in the UV range during the whole day.
- 1 November 2011
- Vol. 31 (11) , 3006-9
[Studies on the remote measurement of the emission of formaldehyde by mobile differential optical absorption spectroscopy].
Formaldehyde (HCHO) is the most abundant carbonyl compounds that play an important role in atmospheric chemistry and photochemical reactions. Formaldehyde is an important indicator of atmospheric reactivity and urban atmospheric aerosol precursors. In the present paper, the emission of formaldehyde from chemical area was measured using the mobile differential optical absorption spectroscopy (DOAS). This instrument uses the zenith scattered sunlight as the light source with successful sampling in the area loop. Vertical column density was retrieved by this system, combined with the meteorological wind field and car speed information, the emission of formaldehyde in the area was estimated. The authors carried out the measuring experiment in one chemical plant in Beijing using this technology. The result showed that the average value of the flux of formaldehyde in this area was 605 kg x h(-1) during the measuring period.
- 1 November 2011
- Vol. 31 (11) , 3006-9
[Studies on the remote measurement of the emission of formaldehyde by mobile differential optical absorption spectroscopy].
Formaldehyde (HCHO) is the most abundant carbonyl compounds that play an important role in atmospheric chemistry and photochemical reactions. Formaldehyde is an important indicator of atmospheric reactivity and urban atmospheric aerosol precursors. In the present paper, the emission of formaldehyde from chemical area was measured using the mobile differential optical absorption spectroscopy (DOAS). This instrument uses the zenith scattered sunlight as the light source with successful sampling in the area loop. Vertical column density was retrieved by this system, combined with the meteorological wind field and car speed information, the emission of formaldehyde in the area was estimated. The authors carried out the measuring experiment in one chemical plant in Beijing using this technology. The result showed that the average value of the flux of formaldehyde in this area was 605 kg x h(-1) during the measuring period.