Taeyon Hwang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Taeyon Hwang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Jeong Tai Kim
Building Technologies Department, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
2 shared publicationsDong Gi Lee
Department of Architecture, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
1 shared publication- Doosam Song
School of Civil, Architectural Eng., and Landscape Architecture, Sungkyunkwan University, 2066 Seobu-ro, Suwon 16419, South Korea
1 shared publication Joonghoon Lee
Technology Research Center, Samsung C&T Corporation, Seoul 137-857, Republic of Korea
1 shared publication
Latest Publications
- 9 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 79-91
Quantitative Reduction Method of Draft in High-Rise Buildings, Using Revolving Doors
Drafts in high-rise buildings caused by the stack effect can cause noise and reduce the performances of ventilation, cooling and heating systems as well as the building’s energy efficiency. Revolving doors are generally used as a method to reduce drafts; however, the effect would only be limited to the main entrance on the lobby floor. Revolving doors have two main advantages; that their opening areas are seldom changed by people passing through the doors, and the doors do not have the pressure-related functional problems. Considering these advantages, this study examined a quantitative draft reduction method using revolving doors in high-rise buildings. This method would contribute to the design process to install revolving doors to buildings and consists of 10 steps with two key steps of selecting the installation locations of revolving doors and to calculate the air leakage area of revolving doors. Verification through simulations showed that, based on this process, the use of revolving doors could reduce the drafts in buildings by a quantified target value. Furthermore, the possibility of problems due to the stack effect in the other walls of buildings would decrease due to the pressure sharing of the additional walls fitted to revolving doors.
- 9 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 79-91
Quantitative Reduction Method of Draft in High-Rise Buildings, Using Revolving Doors
Drafts in high-rise buildings caused by the stack effect can cause noise and reduce the performances of ventilation, cooling and heating systems as well as the building’s energy efficiency. Revolving doors are generally used as a method to reduce drafts; however, the effect would only be limited to the main entrance on the lobby floor. Revolving doors have two main advantages; that their opening areas are seldom changed by people passing through the doors, and the doors do not have the pressure-related functional problems. Considering these advantages, this study examined a quantitative draft reduction method using revolving doors in high-rise buildings. This method would contribute to the design process to install revolving doors to buildings and consists of 10 steps with two key steps of selecting the installation locations of revolving doors and to calculate the air leakage area of revolving doors. Verification through simulations showed that, based on this process, the use of revolving doors could reduce the drafts in buildings by a quantified target value. Furthermore, the possibility of problems due to the stack effect in the other walls of buildings would decrease due to the pressure sharing of the additional walls fitted to revolving doors.
- 6 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 122-128
Optimal Illuminance of Seven Major Lighting Colours in LED: Focus on Occupant Comfort and Communication in an Indoor Environment
This study aims to evaluate the optimal illuminance for each lighting colour of light-emitting diode (LED) light sources among the seven major lighting colours (red, green, blue, cyan, magenta, yellow and white); the focus was on the optimal combination of these colours for enhancement of occupant comfort and communication indoors. The evaluation of optimal illuminance for LED lighting colours found that the occupants felt the cyan LED light source was similar to a white light source, and that the relative brightness of the green lighting colour was higher than that for other colours. The evaluation of the permissible range of illuminance for LED lighting colours found that occupants believed the red lighting colours to be relatively darker; again, the relative brightness of green lighting was considered to be higher. An experiment with subjects for LED lighting colours (consisting of 19 patterns of 7 colours in the living room of a house) found that the optimal illuminance for occupants’ comfort was 32[lx]–119[lx], and for occupants’ communication was 107[lx]–584[lx]. These results satisfied the illuminance criteria of Korean Standards as the optimal illuminance for occupants’ comfort and communication in the living room.
- 6 September 2011
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 21 (1) , 122-128
Optimal Illuminance of Seven Major Lighting Colours in LED: Focus on Occupant Comfort and Communication in an Indoor Environment
This study aims to evaluate the optimal illuminance for each lighting colour of light-emitting diode (LED) light sources among the seven major lighting colours (red, green, blue, cyan, magenta, yellow and white); the focus was on the optimal combination of these colours for enhancement of occupant comfort and communication indoors. The evaluation of optimal illuminance for LED lighting colours found that the occupants felt the cyan LED light source was similar to a white light source, and that the relative brightness of the green lighting colour was higher than that for other colours. The evaluation of the permissible range of illuminance for LED lighting colours found that occupants believed the red lighting colours to be relatively darker; again, the relative brightness of green lighting was considered to be higher. An experiment with subjects for LED lighting colours (consisting of 19 patterns of 7 colours in the living room of a house) found that the optimal illuminance for occupants’ comfort was 32[lx]–119[lx], and for occupants’ communication was 107[lx]–584[lx]. These results satisfied the illuminance criteria of Korean Standards as the optimal illuminance for occupants’ comfort and communication in the living room.