Tausif Monif
Research Subjects
Research Interests
Tausif Monif has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
S.K. Tippabhotla
Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., Udyog Vihar Industrial Area, Gurgaon, Haryana, India
6 shared publicationsArshad H. Khuroo
Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd, GP-5, HSIDC, Sector-18, Udyog Vihar Industrial Area, Old Delhi Gurgaon Road, Gurgaon 122015, Haryana, India
5 shared publicationsArshad Khuroo
Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., HSIDC, GP-5, Old Delhi Gurgaon Road, Udyog Vihar Industrial Area, Gurgaon–122 015, Haryana, India
5 shared publications- Dipanjan Goswami
Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd, Plot no. GP‐5, HSIDC, Sector‐18, Udyog Vihar Industrial Area, Old Delhi Gurgaon Road, Gurgaon 122 015, Haryana, India
5 shared publications Sanjay Gurule
Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., HSIDC, GP-5, Old Delhi Gurgaon Road, Udyog Vihar Industrial Area, Gurgaon–122 015, Haryana, India
5 shared publicationsA.K. Singla
4 shared publications
Latest Publications
- 21 March 2012
- Published by Taylor & Francis in Clinical Research and Regulatory Affairs
- Vol. 29 (1) , 23-34
Bioanalytical method development and validation using incurred samples: Quantitative estimation of metformin in human K3EDTA plasma by LC–MS/MS
Bioanalytical methods should be reproducible and consistent when applying to clinical sample analysis. Incurred sample reanalyses (confirmatory reanalyses) are performed to support clinical data, and regulatory agencies evaluate the same before approval of bioequivalent products/drugs. A confirmatory reanalysis was demonstrated for metformin after administration of 2/500 mg repaglinide + metformin fixed dose formulation under fasted and fed conditions. The liquid chromatography tandem mass spectrometry (LC-MS/MS) method for determination of metformin in human plasma using metformin-d6as an internal standard has been developed and validated. The ions transitions recorded in multiple reaction monitoring (MRM) were m/z 130.1→60.0 and 136.2→60.0 for metformin and metformin-d6, respectively. The compounds were isolated by solid phase extraction and separated on a C12 reverse phase (Synergi MAX-RP 80A) column, using isocratic mobile phase flow at a flow rate of 0.8 mL/min. No matrix effect was observed within the linearity range of 10.2–1741.8 ng/mL (r2 > 0.99). The acceptable result of confirmatory reanalysis further indicated stability of metformin in the presence of repaglinide. The assay method was found to be highly reproducible and was successfully applied for pharmacokinetic evaluations of metformin in fixed dose combinations with repaglinide.
- 21 March 2012
- Published by Taylor & Francis in Clinical Research and Regulatory Affairs
- Vol. 29 (1) , 23-34
Bioanalytical method development and validation using incurred samples: Quantitative estimation of metformin in human K3EDTA plasma by LC–MS/MS
Bioanalytical methods should be reproducible and consistent when applying to clinical sample analysis. Incurred sample reanalyses (confirmatory reanalyses) are performed to support clinical data, and regulatory agencies evaluate the same before approval of bioequivalent products/drugs. A confirmatory reanalysis was demonstrated for metformin after administration of 2/500 mg repaglinide + metformin fixed dose formulation under fasted and fed conditions. The liquid chromatography tandem mass spectrometry (LC-MS/MS) method for determination of metformin in human plasma using metformin-d6as an internal standard has been developed and validated. The ions transitions recorded in multiple reaction monitoring (MRM) were m/z 130.1→60.0 and 136.2→60.0 for metformin and metformin-d6, respectively. The compounds were isolated by solid phase extraction and separated on a C12 reverse phase (Synergi MAX-RP 80A) column, using isocratic mobile phase flow at a flow rate of 0.8 mL/min. No matrix effect was observed within the linearity range of 10.2–1741.8 ng/mL (r2 > 0.99). The acceptable result of confirmatory reanalysis further indicated stability of metformin in the presence of repaglinide. The assay method was found to be highly reproducible and was successfully applied for pharmacokinetic evaluations of metformin in fixed dose combinations with repaglinide.
- 25 November 2011
- Published by Wiley in Biomedical Chromatography
- Vol. 26 (5) , 636-649
ESI‐MS/MS stability‐indicating bioanalytical method development and validation for simultaneous estimation of donepezil, 5‐desmethyl donepezil and 6‐desmethyl donepezil in human plasma
A bioanalytical method was developed and validated to estimate donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil simultaneously in human plasma using galantamine as an internal standard (IS). The chromatographic separation was achieved on a reverse‐phase XTerra RP (150 × 4.6 mm, 5 µm) column without affecting recovery (mean recovery > 60% with CV < 10%) for all analytes. ESI‐MS/MS multiple reaction monitoring in positive polarity was used to detect mass pairs for donepezil (m/z 380.3 → 91.3), 6‐desmethyl donepezil (m/z 366.4 → 91.3), 5‐desmethyl donepezil (m/z 366.4 → 91.3) and galantamine m/z (288.1 → 213.0). The linearity was established over a dynamic range of 0.339–51.870, 0.100–15.380 and 0.103–15.763 ng/mL for donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil, respectively. The current method shows that minimal conversion of labile metabolites to parent donepezil in plasma as stability was successfully achieved for 211 days at −15 °C storage temperature. The method was successfully applied to a clinical study after administration of 10 mg donepezil tablets to healthy male Indian volunteers. Copyright © 2011 John Wiley & Sons, Ltd.
- 25 November 2011
- Published by Wiley in Biomedical Chromatography
- Vol. 26 (5) , 636-649
ESI‐MS/MS stability‐indicating bioanalytical method development and validation for simultaneous estimation of donepezil, 5‐desmethyl donepezil and 6‐desmethyl donepezil in human plasma
A bioanalytical method was developed and validated to estimate donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil simultaneously in human plasma using galantamine as an internal standard (IS). The chromatographic separation was achieved on a reverse‐phase XTerra RP (150 × 4.6 mm, 5 µm) column without affecting recovery (mean recovery > 60% with CV < 10%) for all analytes. ESI‐MS/MS multiple reaction monitoring in positive polarity was used to detect mass pairs for donepezil (m/z 380.3 → 91.3), 6‐desmethyl donepezil (m/z 366.4 → 91.3), 5‐desmethyl donepezil (m/z 366.4 → 91.3) and galantamine m/z (288.1 → 213.0). The linearity was established over a dynamic range of 0.339–51.870, 0.100–15.380 and 0.103–15.763 ng/mL for donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil, respectively. The current method shows that minimal conversion of labile metabolites to parent donepezil in plasma as stability was successfully achieved for 211 days at −15 °C storage temperature. The method was successfully applied to a clinical study after administration of 10 mg donepezil tablets to healthy male Indian volunteers. Copyright © 2011 John Wiley & Sons, Ltd.
- 14 March 2011
- Published by Wiley in Biomedical Chromatography
- Vol. 25 (11) , 1189-1200
Controlled ex‐vivo plasma hydrolysis of valaciclovir to acyclovir demonstration using tandem mass spectrometry
Plasma estimation of valaciclovir, an antiviral drug, is challenging due to both in‐vivo and ex‐vivo hydrolysis to active metabolite acyclovir. A simultaneous method is described involving the solid‐phase ion‐exchange extraction procedure requiring 100 μL of plasma volume, a reverse‐phase Lichrosphere RP Select B (125 × 6 mm, 5 μm) column and isocratic mobile phase to achieve the desired chromatographic separation. ESI‐MS/MS multiple reaction monitoring in positive polarity, detected mass pairs for valaciclovir (m/z 325.5 → 152.2), acyclovir (m/z 226.3 → 152.2) and respective internal standards valganciclovir (m/z 307.1 → 220.3) and acyclovir‐d4 (m/z 230.2 → 152.0). Fully fledged method validation was evaluated as per current regulatory requirements and results were deemed acceptable. The plasma samples showed extensive hydrolysis of valaciclovir when collected or processed at room temperature, without buffer stabilization prior to storage at −15°C. Our results showed that using prechilled K3EDTA vacutainers immersed in an iced‐water bath during blood sample collection, and addition of 50% orthophosphoric acid solution to plasma samples prior to storage at −50°C for at least 120 days controlled the hydrolysis of valaciclovir to acyclovir. While monitoring drug absorption into systematic circulation, the valaciclovir to acyclovir formation ratio was improved to 1:20 in healthy volunteers for the first time. Copyright © 2011 John Wiley & Sons, Ltd.
- 14 March 2011
- Published by Wiley in Biomedical Chromatography
- Vol. 25 (11) , 1189-1200
Controlled ex‐vivo plasma hydrolysis of valaciclovir to acyclovir demonstration using tandem mass spectrometry
Plasma estimation of valaciclovir, an antiviral drug, is challenging due to both in‐vivo and ex‐vivo hydrolysis to active metabolite acyclovir. A simultaneous method is described involving the solid‐phase ion‐exchange extraction procedure requiring 100 μL of plasma volume, a reverse‐phase Lichrosphere RP Select B (125 × 6 mm, 5 μm) column and isocratic mobile phase to achieve the desired chromatographic separation. ESI‐MS/MS multiple reaction monitoring in positive polarity, detected mass pairs for valaciclovir (m/z 325.5 → 152.2), acyclovir (m/z 226.3 → 152.2) and respective internal standards valganciclovir (m/z 307.1 → 220.3) and acyclovir‐d4 (m/z 230.2 → 152.0). Fully fledged method validation was evaluated as per current regulatory requirements and results were deemed acceptable. The plasma samples showed extensive hydrolysis of valaciclovir when collected or processed at room temperature, without buffer stabilization prior to storage at −15°C. Our results showed that using prechilled K3EDTA vacutainers immersed in an iced‐water bath during blood sample collection, and addition of 50% orthophosphoric acid solution to plasma samples prior to storage at −50°C for at least 120 days controlled the hydrolysis of valaciclovir to acyclovir. While monitoring drug absorption into systematic circulation, the valaciclovir to acyclovir formation ratio was improved to 1:20 in healthy volunteers for the first time. Copyright © 2011 John Wiley & Sons, Ltd.
- 1 December 2010
- Published by Dustri-Verlag Dr. Karl Feistle in Int. Journal of Clinical Pharmacology and Therapeutics
- Vol. 48 (12) , 868-876
A pharmacokinetic and bioequivalence study of Contiflo ICON 400 µg tablets in healthy Indian subjects
Tamsulosin, an alpha1 adrenoceptor blocking agent, exhibits selectivity for alpha1 receptors in human prostate. Blockade of these adrenoceptors can cause smooth muscles in the bladder neck and prostate to relax, resulting in an improvement in urine flow rate and a reduction in symptoms of benign prostatic hypertrophy. A new formulation Contiflo ICON 400 µg has been developed by Ranbaxy Laboratories Limited, India similar to Flomaxtra XL 400 µg of Astellas Pharma Limited, United Kingdom. This product is specifically designed to achieve a more consistent plasma concentration over a period of 24-h, a lower maximum plasma concentration (Cmax) and an independence of pharmacokinetics (PKs) on food intake. The objective of the present study was to evaluate the pharmacokinetics and bioequivalence of the new formulation Contiflo ICON 400 µg of Ranbaxy Laboratories Limited, India and Flomaxtra XL 400 µg prolonged release tablets (containing tamsulosin hydrochloride prolonged release 400 µg) of Astellas Pharma Limited, United Kingdom. Study was conducted as an open label, balanced, randomized, two-treatment, two-period, two-sequence, cross over, single-dose bioequivalence study in 32 adult male human subjects under fed conditions. The mean (range) age, weight and height of the study subjects were 27.03 years (19 - 40 years), 57.19 kg (48 - 72 kg) and 166.81 cm (154 - 181 cm) respectively. Blood samples were collected at pre-dose and at 0.5, 1, 2, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 8, 9, 10, 12, 16, 20, 24, 36, 48, 72, and 96 h post dose in each period. Plasma samples were analyzed for tamsulosin by using validated liquid chromatographic mass spectrometry (LC-MS/MS) method. The Mean ± SD of pharmacokinetic parameters tmax, Cmax, AUC24, AUClast and AUCinf for Tamsulosin were 11.741 ± 4.7201 and 12.155 ± 6.3077 h, 10.7614 ± 4.76709 and 10.4954 ± 5.08979 ng/ml, 171.4674 ± 77.39695 and 160.6738 ± 77.98628 ng.h/ml, 262.7771 ± 150.21432 and 250.6854 ± 156.75581 ng.h/ml, 280.0702 ± 152.14253 and 273.5078 ± 156.85910 ng.h/ml for test and reference formulations respectively. The ratios of least square means and the 90% confidence interval of log transformed pharmacokinetic parameter Cmax, AUC24, AUClast and AUCinf were within 80 - 125% acceptance range. In conclusion, Contiflo ICON 400 µg tablets developed by Ranbaxy Laboratories Limited is bioequivalent to the reference formulation in healthy adult male volunteers under fed condition.
- 1 December 2010
- Published by Dustri-Verlag Dr. Karl Feistle in Int. Journal of Clinical Pharmacology and Therapeutics
- Vol. 48 (12) , 868-876
A pharmacokinetic and bioequivalence study of Contiflo ICON 400 µg tablets in healthy Indian subjects
Tamsulosin, an alpha1 adrenoceptor blocking agent, exhibits selectivity for alpha1 receptors in human prostate. Blockade of these adrenoceptors can cause smooth muscles in the bladder neck and prostate to relax, resulting in an improvement in urine flow rate and a reduction in symptoms of benign prostatic hypertrophy. A new formulation Contiflo ICON 400 µg has been developed by Ranbaxy Laboratories Limited, India similar to Flomaxtra XL 400 µg of Astellas Pharma Limited, United Kingdom. This product is specifically designed to achieve a more consistent plasma concentration over a period of 24-h, a lower maximum plasma concentration (Cmax) and an independence of pharmacokinetics (PKs) on food intake. The objective of the present study was to evaluate the pharmacokinetics and bioequivalence of the new formulation Contiflo ICON 400 µg of Ranbaxy Laboratories Limited, India and Flomaxtra XL 400 µg prolonged release tablets (containing tamsulosin hydrochloride prolonged release 400 µg) of Astellas Pharma Limited, United Kingdom. Study was conducted as an open label, balanced, randomized, two-treatment, two-period, two-sequence, cross over, single-dose bioequivalence study in 32 adult male human subjects under fed conditions. The mean (range) age, weight and height of the study subjects were 27.03 years (19 - 40 years), 57.19 kg (48 - 72 kg) and 166.81 cm (154 - 181 cm) respectively. Blood samples were collected at pre-dose and at 0.5, 1, 2, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 8, 9, 10, 12, 16, 20, 24, 36, 48, 72, and 96 h post dose in each period. Plasma samples were analyzed for tamsulosin by using validated liquid chromatographic mass spectrometry (LC-MS/MS) method. The Mean ± SD of pharmacokinetic parameters tmax, Cmax, AUC24, AUClast and AUCinf for Tamsulosin were 11.741 ± 4.7201 and 12.155 ± 6.3077 h, 10.7614 ± 4.76709 and 10.4954 ± 5.08979 ng/ml, 171.4674 ± 77.39695 and 160.6738 ± 77.98628 ng.h/ml, 262.7771 ± 150.21432 and 250.6854 ± 156.75581 ng.h/ml, 280.0702 ± 152.14253 and 273.5078 ± 156.85910 ng.h/ml for test and reference formulations respectively. The ratios of least square means and the 90% confidence interval of log transformed pharmacokinetic parameter Cmax, AUC24, AUClast and AUCinf were within 80 - 125% acceptance range. In conclusion, Contiflo ICON 400 µg tablets developed by Ranbaxy Laboratories Limited is bioequivalent to the reference formulation in healthy adult male volunteers under fed condition.
- 14 September 2010
- Published by Wiley in Biomedical Chromatography
- Vol. 25 (6) , 680-688
Stability‐indicating validation of acitretin and isoacitretin in human plasma by LC‐ESI‐MS/MS bioanalytical method and its application to pharmacokinetic analysis
LC‐ ESI‐ MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin‐d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid–liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin‐d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis‐RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025–753.217 ng/mL for acitretin and 0.394–289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra‐day and inter‐day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.
- 14 September 2010
- Published by Wiley in Biomedical Chromatography
- Vol. 25 (6) , 680-688
Stability‐indicating validation of acitretin and isoacitretin in human plasma by LC‐ESI‐MS/MS bioanalytical method and its application to pharmacokinetic analysis
LC‐ ESI‐ MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin‐d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid–liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin‐d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis‐RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025–753.217 ng/mL for acitretin and 0.394–289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra‐day and inter‐day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.
- 23 April 2010
- Published by Wiley in Biomedical Chromatography
- Vol. 24 (11) , 1168-1178
Rational design for variability minimization in bioanalytical method validation: illustration with LC‐MS/MS assay method for terbinafine estimation in human plasma
Terbinafine, a widely used antifungal drug, is a challenging molecule for quantitative bioanalysis due to certain factors contributing assay variability. Despite previous attempts at human plasma determination of terbinafine, exhaustive stability of the drug or an internal standard was lacking. Internal standard stability with negligible variation throughout the analysis is an indicator of a reliable bioanalytical method as the majority of LC–MS/MS assays are based on analyte/IS response ratios for quantitation. A newly developed high‐throughput simple LC‐MS/MS method is described for human plasma determination of terbinafine using naftifine internal standard and eluting all compounds within 2 min. A solid‐phase extraction of terbinafine achieving mean recovery of 84.3% (CV < 4%) without compromising sensitivity (limit of quantitation 5.11 ng/mL) or linearity (5.11–3014.19 ng/mL) is delineated in this paper. A heated nebulizer in positive multiple reaction monitoring mode was employed with transitions m/z 292.2 →141.1 and 288.2 →117.0 for terbinafine and naftifine, respectively, resulting in excellent chromatographic separation on a Hypurity Advance (50 × 4.6 mm, 5 µm) column. The developed method was successfully applied to clinical samples and for the first time demonstrated marked improved extraction efficiency and reliable long‐term plasma stability results without any internal standard response variation during the entire course of study. Copyright © 2010 John Wiley & Sons, Ltd.
- 23 April 2010
- Published by Wiley in Biomedical Chromatography
- Vol. 24 (11) , 1168-1178
Rational design for variability minimization in bioanalytical method validation: illustration with LC‐MS/MS assay method for terbinafine estimation in human plasma
Terbinafine, a widely used antifungal drug, is a challenging molecule for quantitative bioanalysis due to certain factors contributing assay variability. Despite previous attempts at human plasma determination of terbinafine, exhaustive stability of the drug or an internal standard was lacking. Internal standard stability with negligible variation throughout the analysis is an indicator of a reliable bioanalytical method as the majority of LC–MS/MS assays are based on analyte/IS response ratios for quantitation. A newly developed high‐throughput simple LC‐MS/MS method is described for human plasma determination of terbinafine using naftifine internal standard and eluting all compounds within 2 min. A solid‐phase extraction of terbinafine achieving mean recovery of 84.3% (CV < 4%) without compromising sensitivity (limit of quantitation 5.11 ng/mL) or linearity (5.11–3014.19 ng/mL) is delineated in this paper. A heated nebulizer in positive multiple reaction monitoring mode was employed with transitions m/z 292.2 →141.1 and 288.2 →117.0 for terbinafine and naftifine, respectively, resulting in excellent chromatographic separation on a Hypurity Advance (50 × 4.6 mm, 5 µm) column. The developed method was successfully applied to clinical samples and for the first time demonstrated marked improved extraction efficiency and reliable long‐term plasma stability results without any internal standard response variation during the entire course of study. Copyright © 2010 John Wiley & Sons, Ltd.
- 1 October 2009
- Published by Georg Thieme Verlag KG in Arzneimittelforschung
- Vol. 59 (10) , 521-525
Two-way Crossover Bioequivalence Study of Alendronate Sodium Tablets in Healthy, Non-smoking Male Volunteers under Fasted Conditions
This study was conducted in order to assess the bioequivalence of two different formulations containing 70 mg alendronate sodium (CAS 121268-17-5) under fasted conditions. One hundred twenty-two healthy male volunteers were enrolled in an open label, randomized, crossover design with a wash-out period of 20 days in one study center. Urine samples were collected up to 36 h post-dose, and the concentrations of alendronic acid were determined using a high performance liquid chromatographic method with pre-derivatization and fluorescence detection (HPLC/FL) method. The mean Ae0–t were 604.24 ± 348.73 µg and 627.36 ± 327.99 µg, while the mean Rmax were 193.87 ± 114.68 µg/h and 202.00 ± 107.83 µg/h for the test and reference formulations, respectively. The Tmax of the test and reference tablets were 1.26 ± 0.58 h and 1.26 ± 0.51 h, respectively. No significant differences of pharmacokinetic parameters between the two studied formulations were found. The 90% confidence intervals for the primary target parameters, intra-individual ratios for Ae0–t and Rmax of alendronic acid, were between 0.86–1.00 and 0.85–1.01, respectively, and thus within the acceptance range for bioequivalence criteria. In the light of the present study it can be concluded that the test formulation is bioequivalent to the reference formulation.
- 1 October 2009
- Published by Georg Thieme Verlag KG in Arzneimittelforschung
- Vol. 59 (10) , 521-525
Two-way Crossover Bioequivalence Study of Alendronate Sodium Tablets in Healthy, Non-smoking Male Volunteers under Fasted Conditions
This study was conducted in order to assess the bioequivalence of two different formulations containing 70 mg alendronate sodium (CAS 121268-17-5) under fasted conditions. One hundred twenty-two healthy male volunteers were enrolled in an open label, randomized, crossover design with a wash-out period of 20 days in one study center. Urine samples were collected up to 36 h post-dose, and the concentrations of alendronic acid were determined using a high performance liquid chromatographic method with pre-derivatization and fluorescence detection (HPLC/FL) method. The mean Ae0–t were 604.24 ± 348.73 µg and 627.36 ± 327.99 µg, while the mean Rmax were 193.87 ± 114.68 µg/h and 202.00 ± 107.83 µg/h for the test and reference formulations, respectively. The Tmax of the test and reference tablets were 1.26 ± 0.58 h and 1.26 ± 0.51 h, respectively. No significant differences of pharmacokinetic parameters between the two studied formulations were found. The 90% confidence intervals for the primary target parameters, intra-individual ratios for Ae0–t and Rmax of alendronic acid, were between 0.86–1.00 and 0.85–1.01, respectively, and thus within the acceptance range for bioequivalence criteria. In the light of the present study it can be concluded that the test formulation is bioequivalent to the reference formulation.
- 25 August 2009
- Published by Wiley in Biomedical Chromatography
- Vol. 24 (5) , 497-505
LC‐APCI mass spectrometric method development and validation for the determination of atovaquone in human plasma
A newly developed LC—APCI mass spectrometric method is described for human plasma determination of atovaquone using lapachol internal standard. A single‐step protein precipitation technique for plasma extraction of atovaquone achieving mean recovery of 94.17% (CV 8%) without compromising sensitivity (limit of quantitation 50.3 ng/mL) or linearity (50.3 ng/mL—23924.6 ng/mL) is delineated in this paper. Heated nebulizer in negative multiple reaction monitoring mode was employed with transitions m/z 365.2 → m/z 337.1 and m/z 240.9 → m/z 185.7 for atovaquone and lapachol respectively in this liquid chromatographic–tandem mass spectrometric method. Excellent chromatographic separation on a Synergi 4 μ Polar‐RP 80A (150 × 2.0 mm) column, using 100 μL of plasma extraction volume along with 10 μL of injection load, completing analysis run‐time within 2.5 min, highlights this simple yet unique bioanalytical method. The developed method can be successfully applied to pharmacokinetic studies on atovaquone suspension administered in healthy volunteers or HIV‐infected patients. Moreover full method validation results not published before are presented and discussed in detail for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd.
- 25 August 2009
- Published by Wiley in Biomedical Chromatography
- Vol. 24 (5) , 497-505
LC‐APCI mass spectrometric method development and validation for the determination of atovaquone in human plasma
A newly developed LC—APCI mass spectrometric method is described for human plasma determination of atovaquone using lapachol internal standard. A single‐step protein precipitation technique for plasma extraction of atovaquone achieving mean recovery of 94.17% (CV 8%) without compromising sensitivity (limit of quantitation 50.3 ng/mL) or linearity (50.3 ng/mL—23924.6 ng/mL) is delineated in this paper. Heated nebulizer in negative multiple reaction monitoring mode was employed with transitions m/z 365.2 → m/z 337.1 and m/z 240.9 → m/z 185.7 for atovaquone and lapachol respectively in this liquid chromatographic–tandem mass spectrometric method. Excellent chromatographic separation on a Synergi 4 μ Polar‐RP 80A (150 × 2.0 mm) column, using 100 μL of plasma extraction volume along with 10 μL of injection load, completing analysis run‐time within 2.5 min, highlights this simple yet unique bioanalytical method. The developed method can be successfully applied to pharmacokinetic studies on atovaquone suspension administered in healthy volunteers or HIV‐infected patients. Moreover full method validation results not published before are presented and discussed in detail for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd.
- 10 July 2009
- Published by Wiley in Biomedical Chromatography
- Vol. 23 (11) , 1227-1241
Bioanalytical LC‐MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers
A LC‐MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge‐coupled solid‐phase extraction and reverse‐phase chromatographic separation was performed on an Ascentis C18 column. Turbo‐spray negative‐ion mode multiple‐reaction monitoring was selected for mass pair detection at m/z 338.3 → 78.0 and m/z 407.3 → 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half‐life matching for test and reference drug was achieved with 73.43 ± 9.68 and 73.06 ± 14.03 h, respectively, and intra‐subject coefficient of variation achieved within 11% for AUCs and Cmax evaluated by non‐compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd.
- 10 July 2009
- Published by Wiley in Biomedical Chromatography
- Vol. 23 (11) , 1227-1241
Bioanalytical LC‐MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers
A LC‐MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge‐coupled solid‐phase extraction and reverse‐phase chromatographic separation was performed on an Ascentis C18 column. Turbo‐spray negative‐ion mode multiple‐reaction monitoring was selected for mass pair detection at m/z 338.3 → 78.0 and m/z 407.3 → 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half‐life matching for test and reference drug was achieved with 73.43 ± 9.68 and 73.06 ± 14.03 h, respectively, and intra‐subject coefficient of variation achieved within 11% for AUCs and Cmax evaluated by non‐compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd.
- 27 March 2009
- Published by Taylor & Francis in Clinical Research and Regulatory Affairs
- Vol. 26 (1-2) , 24-36
Liquid chromatographic tandem mass spectrometric validated method for pharmacokinetic estimation of flecainide in human plasma
A sensitive high throughput LC/MS/MS method fully validated as per USFDA guidelines is described for pharmacokinetic estimation of flecainide in human plasma using loperamide as the internal standard. Plasma samples were monitored by cation exchange solid phase extraction achieving 78.6% extraction efficiency (mean recovery) followed by chromatographic separation on a PurospherStar RP-18e column. Detection was carried out on an API positive ESI by MRM transitions m/z 415.2/301.1 and 477.3/266.3 for flecainide and loperamide respectively. High sensitivity of 1.17ng/ml, dynamic linearity of 1.17–396.75 ng/ml and short run time within 3 minutes are other interesting aspects of this new bioanalytical method. This method was successfully applied to a pharmacokinetic study with 100mg tablet flecainide administered in Indian population for the first time. A randomized, single dose, two sequence, cross over study design was used to evaluate bioequivalence on 40 healthy male fasted volunteers and blood samples were collected up to 96 hours post dose. Noncompartmental pharmacokinetic analysis was used to evaluate AUC0-t, AUC0-inf, Cmax, Tmax, T1/2 and λz scaled on a 90% confidence interval approach. Average bioequivalence results showed ratios of least square means and its 90% CIs for ln-transformed Cmax, AUC0-t and AUC0-inf for flecainide were 99.99 (95.21–104.99) %, 98.27(93.89–102.86)% and 98.08(93.68–102.68)% respectively. Both the test and reference products were closely comparable in terms of rate and extent to which the drugs access the systemic circulation.
- 27 March 2009
- Published by Taylor & Francis in Clinical Research and Regulatory Affairs
- Vol. 26 (1-2) , 24-36
Liquid chromatographic tandem mass spectrometric validated method for pharmacokinetic estimation of flecainide in human plasma
A sensitive high throughput LC/MS/MS method fully validated as per USFDA guidelines is described for pharmacokinetic estimation of flecainide in human plasma using loperamide as the internal standard. Plasma samples were monitored by cation exchange solid phase extraction achieving 78.6% extraction efficiency (mean recovery) followed by chromatographic separation on a PurospherStar RP-18e column. Detection was carried out on an API positive ESI by MRM transitions m/z 415.2/301.1 and 477.3/266.3 for flecainide and loperamide respectively. High sensitivity of 1.17ng/ml, dynamic linearity of 1.17–396.75 ng/ml and short run time within 3 minutes are other interesting aspects of this new bioanalytical method. This method was successfully applied to a pharmacokinetic study with 100mg tablet flecainide administered in Indian population for the first time. A randomized, single dose, two sequence, cross over study design was used to evaluate bioequivalence on 40 healthy male fasted volunteers and blood samples were collected up to 96 hours post dose. Noncompartmental pharmacokinetic analysis was used to evaluate AUC0-t, AUC0-inf, Cmax, Tmax, T1/2 and λz scaled on a 90% confidence interval approach. Average bioequivalence results showed ratios of least square means and its 90% CIs for ln-transformed Cmax, AUC0-t and AUC0-inf for flecainide were 99.99 (95.21–104.99) %, 98.27(93.89–102.86)% and 98.08(93.68–102.68)% respectively. Both the test and reference products were closely comparable in terms of rate and extent to which the drugs access the systemic circulation.