Friedhelm Heinemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Friedhelm Heinemann has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Christoph Bourauel
8 shared publicationsIstabrak Hasan
Endowed Chair of Oral Technology, Department of Prosthodontics, Preclinical Education and Dental Materials Science, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany; Department of Prosthodontics, Preclinical Education and Dental Materials Science, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany
7 shared publications- Marzena Dominiak
Oral Surgery Department, Wroclaw Medical University, 50-425 Wroclaw, Poland
5 shared publications Torsten Mundt
Department of Prosthodontics, Gerodontology and Biomaterials, University of Greifswald, Rotgerberstr. 8, 17489 Greifswald, Germany
5 shared publicationsChristian Schwahn
4 shared publicationsLudger Keilig
4 shared publications
Latest Publications
- 14 July 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (3) , 1
Próteses parciais fixas definitivas em oclusão imediata versus restaurações provisórias em infraoclusão – resultados de um acompanhamento de 4 meses pós-carga de um ensaio clínico randomizado controlado multicêntrico pragmático
- 14 July 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (3) , 1
Próteses parciais fixas definitivas em oclusão imediata versus restaurações provisórias em infraoclusão – resultados de um acompanhamento de 4 meses pós-carga de um ensaio clínico randomizado controlado multicêntrico pragmático
- 12 April 2016
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (1) , 103-108
Experimental investigation of commercial small diameter dental implants in porcine mandibular segments
Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.
- 12 April 2016
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (1) , 103-108
Experimental investigation of commercial small diameter dental implants in porcine mandibular segments
Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.
- 1 January 2016
- Vol. 9 (1) , 47-56
Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.
To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed no statistical significance (8.26 versus 7.58; P = 0.445); the same was seen for aesthetics evaluated by patients (Mann-Whitney U test: P = 0.618). Patients in the non-occlusal group were significantly more satisfied with the function of their implant-supported prostheses (Mann-Whitney U test: P = 0.039). Significantly less chair time (mean difference = -28.4 min; 95% CI: -48.82 to -7.99; P = 0.007) and the number of visits (mean difference = -1.88; 95% CI: -2.43 to -1.33; P < 0.001) were required for the immediate definitive prosthesis group. This study did not provide a conclusive answer but may suggest that provisional prostheses non-occlusally immediately loaded may increase patient functional satisfaction, chair time and the number of visits, with respect to definitive prostheses immediately loaded in functional occlusion.
- 1 January 2016
- Vol. 9 (1) , 47-56
Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.
To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed no statistical significance (8.26 versus 7.58; P = 0.445); the same was seen for aesthetics evaluated by patients (Mann-Whitney U test: P = 0.618). Patients in the non-occlusal group were significantly more satisfied with the function of their implant-supported prostheses (Mann-Whitney U test: P = 0.039). Significantly less chair time (mean difference = -28.4 min; 95% CI: -48.82 to -7.99; P = 0.007) and the number of visits (mean difference = -1.88; 95% CI: -2.43 to -1.33; P < 0.001) were required for the immediate definitive prosthesis group. This study did not provide a conclusive answer but may suggest that provisional prostheses non-occlusally immediately loaded may increase patient functional satisfaction, chair time and the number of visits, with respect to definitive prostheses immediately loaded in functional occlusion.
- 1 May 2015
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 199, 3-8
Bone stability around dental implants: Treatment related factors
- 1 May 2015
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 199, 3-8
Bone stability around dental implants: Treatment related factors
- 1 January 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 46, 177-183
Socket augmentation using a commercial collagen-based product — an animal study in pigs
- 1 January 2015
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 46, 177-183
Socket augmentation using a commercial collagen-based product — an animal study in pigs
- 1 January 2014
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 59 (6) , 507-513
Biomechanical investigations of the secondary stability of commercial short dental implants in porcine ribs
The use of short implants has increased widely within the last years. However, the stability of these implants has not yet been comprehensively investigated, in particular the difference in geometry and dimension of short implants. The aim of the present study was to investigate experimentally the difference of the secondary stability of different commercial short implants by measuring their displacements. Eleven implant geometries were investigated in this study. A total of 22 implants were inserted in porcine rib segments, two implants for each system. Implant displacements were measured using a self-developed biomechanical hexapod measurement system (HexMeS). The highest displacement was observed with Straumann BL NC 3.3×8.0 mm (266 μm), followed by Straumann Standard 4.1×6.0 mm (156 μm), while the lowest displacement of 61 μm was shown by Dentaurum type 1 implant (4.2×5.0 mm). No obvious difference of displacements was observed between hammered and screw-shaped implants with relevant dimensions. The experimental results were in good agreement with the numerical ones (19-42%) for Dentaurum implants. However, a difference of 70-80% was obtained for the Astra implant (4.0×6.0 mm) and Bicon implant (6.0×5.7 mm). The geometry of short implants directly affects their stability within the bone.
- 1 January 2014
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 59 (6) , 507-513
Biomechanical investigations of the secondary stability of commercial short dental implants in porcine ribs
The use of short implants has increased widely within the last years. However, the stability of these implants has not yet been comprehensively investigated, in particular the difference in geometry and dimension of short implants. The aim of the present study was to investigate experimentally the difference of the secondary stability of different commercial short implants by measuring their displacements. Eleven implant geometries were investigated in this study. A total of 22 implants were inserted in porcine rib segments, two implants for each system. Implant displacements were measured using a self-developed biomechanical hexapod measurement system (HexMeS). The highest displacement was observed with Straumann BL NC 3.3×8.0 mm (266 μm), followed by Straumann Standard 4.1×6.0 mm (156 μm), while the lowest displacement of 61 μm was shown by Dentaurum type 1 implant (4.2×5.0 mm). No obvious difference of displacements was observed between hammered and screw-shaped implants with relevant dimensions. The experimental results were in good agreement with the numerical ones (19-42%) for Dentaurum implants. However, a difference of 70-80% was obtained for the Astra implant (4.0×6.0 mm) and Bicon implant (6.0×5.7 mm). The geometry of short implants directly affects their stability within the bone.
- 1 May 2013
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 33 (3) , 365-372
Bone Level Changes in Dental Implants with Platform-Switched Design After Immediate and Delayed Placement in the Maxilla
Friedhelm Heinemann, DDS, PhD/Reiner Biffar, DDS, PhD/Christian Schwahn, DSc, PhD/Torsten Mundt, DDS, PhD: This study sought to evaluate platform-switched implants for immediate placement. A total of 136 implants were placed in 58 patients using either an immediate or delayed implant protocol. Bone level changes of the implants were measured mesially and distally and statistically analyzed with linear mixed models. No implant was lost. There was no significant difference between immediate and delayed implants in approximal bone level changes during the first year (95% confidence interval: ?0.10 to ?0.01 for immediate versus ?0.14 to ?0.07 for delayed implants). Subsequent bone resorption was negligible in both groups. (Int J Periodontics Restorative Dent 2013;33:365?372. doi: 10.11607/prd.1276)
- 1 May 2013
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 33 (3) , 365-372
Bone Level Changes in Dental Implants with Platform-Switched Design After Immediate and Delayed Placement in the Maxilla
Friedhelm Heinemann, DDS, PhD/Reiner Biffar, DDS, PhD/Christian Schwahn, DSc, PhD/Torsten Mundt, DDS, PhD: This study sought to evaluate platform-switched implants for immediate placement. A total of 136 implants were placed in 58 patients using either an immediate or delayed implant protocol. Bone level changes of the implants were measured mesially and distally and statistically analyzed with linear mixed models. No implant was lost. There was no significant difference between immediate and delayed implants in approximal bone level changes during the first year (95% confidence interval: ?0.10 to ?0.01 for immediate versus ?0.14 to ?0.07 for delayed implants). Subsequent bone resorption was negligible in both groups. (Int J Periodontics Restorative Dent 2013;33:365?372. doi: 10.11607/prd.1276)
- 1 November 2012
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 194 (6) , 501
Oral Tissue Engineering and Implants
- 1 November 2012
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 194 (6) , 501
Oral Tissue Engineering and Implants
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S178
BIOMECHANICAL ANALYSIS OF SMALL DIAMETER AND SHORT DENTAL IMPLANTS
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S178
BIOMECHANICAL ANALYSIS OF SMALL DIAMETER AND SHORT DENTAL IMPLANTS