Milan Držík
Milan Držík has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Juraj Chlpík
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, SK-812 19, Bratislava, Slovakia
3 shared publications - Marian Vojs
Faculty of Electrical Engineering and Information Technology, Institute of Electronics and Photonics, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19, Bratislava, Slovakia
2 shared publications - Alexander Kromka
Institute of Physics of the Czech Academy of Sciences Prague Czech Republic
1 shared publication - Alois Necas
Department of Surgery and Orthopedics, Small Animal Clinic, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences Brno, Czech Republic
1 shared publication - Bohumír Zaťko
Institute of Electrical Engineering, Slovak Academy of Sciences, Dúbravská cesta 9, SK-841 04 Bratislava, Slovak Republic
1 shared publication E Amler
1 shared publication
Latest Publications
- 6 November 2023
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 26 (3) , 531-540
Development of a technique for inductive measurement of laser-induced magnetization dynamics in thin films
- 6 November 2023
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 26 (3) , 531-540
Development of a technique for inductive measurement of laser-induced magnetization dynamics in thin films
- Open Access
- 30 December 2020
- Published by MDPI AG in Proceedings
- Vol. 56 (1) , 35
Direct Deposition of CVD Diamond Layers on Top of GaN Membranes
We present technological issues in the deposition of diamond films on gallium nitride (GaN) membranes. Many wrinkles and thicker diamond layers were observed at the membrane center and poor quality diamond outside the membrane area. The deflection of the membranes was analyzed by a bulging method using white light interferometry. The membrane bending is discussed in the terms of temperature gradient and mismatch of thermal expansion coefficients of materials.
- 30 December 2020
- Published by MDPI AG in Proceedings
- Vol. 56 (1) , 35
Open AccessDirect Deposition of CVD Diamond Layers on Top of GaN Membranes
We present technological issues in the deposition of diamond films on gallium nitride (GaN) membranes. Many wrinkles and thicker diamond layers were observed at the membrane center and poor quality diamond outside the membrane area. The deflection of the membranes was analyzed by a bulging method using white light interferometry. The membrane bending is discussed in the terms of temperature gradient and mismatch of thermal expansion coefficients of materials.
- 1 November 2017
- Published by Elsevier in Optics Communications
- Vol. 402, 109-114
Measurement of azimuthal dependence of resonant coupling in 2D photonic crystals
- 1 November 2017
- Published by Elsevier in Optics Communications
- Vol. 402, 109-114
Measurement of azimuthal dependence of resonant coupling in 2D photonic crystals
- 6 March 2012
- Published by SAGE Publications in Journal of Building Physics
- Vol. 35 (4) , 309-326
Experimental and numerical analysis of the boundary layer on a vertical plate at low temperature differences
The problem of heat convection from surface to air at very low temperature differences has been solved by experimental/numerical approach. The laser-based probing technique of laser beam deviation detection was developed for the measurement of air refractive index gradients. The data obtained were processed by interactive coupling with numerical modelling tools. As it was approved, the key properties of the boundary layer such as temperature and temperature gradient profiles can be analysed in detail and the impact of various factors can be studied. The numerical simulation and the experimental data comparison had shown good coincidence; nevertheless, at a temperature difference of only few degrees, the influence of ambient air movement has to be considered in simulation process. The presented boundary layer analysis can be successfully applied at specific conditions of building physics with the low temperature differences.
- 6 March 2012
- Published by SAGE Publications in Journal of Building Physics
- Vol. 35 (4) , 309-326
Experimental and numerical analysis of the boundary layer on a vertical plate at low temperature differences
The problem of heat convection from surface to air at very low temperature differences has been solved by experimental/numerical approach. The laser-based probing technique of laser beam deviation detection was developed for the measurement of air refractive index gradients. The data obtained were processed by interactive coupling with numerical modelling tools. As it was approved, the key properties of the boundary layer such as temperature and temperature gradient profiles can be analysed in detail and the impact of various factors can be studied. The numerical simulation and the experimental data comparison had shown good coincidence; nevertheless, at a temperature difference of only few degrees, the influence of ambient air movement has to be considered in simulation process. The presented boundary layer analysis can be successfully applied at specific conditions of building physics with the low temperature differences.
- 31 May 2007
- p. S61-8
Biomechanical characterization of cartilages by a novel approach of blunt impact testing.
The present article introduces a novel method of characterizing the macromechanical cartilage properties based on dynamic testing. The proposed approach of instrumented impact testing shows the possibility of more detailed investigation of the acting dynamic forces and corresponding deformations within the wide range of strain rates and loads, including the unloading part of stress-strain curves and hysteresis loops. The presented results of the unconfined compression testing of both the native joint cartilage tissues and potential substitute materials outlined the opportunity to measure the dissipation energy and thus to identify the initial mechanical deterioration symptoms and to introduce a better definition of material damage. Based on the analysis of measured specimen deformation, the intact and pathologically changed cartilage tissue can be distinguished and the differences revealed.
- 31 May 2007
- p. S61-8
Biomechanical characterization of cartilages by a novel approach of blunt impact testing.
The present article introduces a novel method of characterizing the macromechanical cartilage properties based on dynamic testing. The proposed approach of instrumented impact testing shows the possibility of more detailed investigation of the acting dynamic forces and corresponding deformations within the wide range of strain rates and loads, including the unloading part of stress-strain curves and hysteresis loops. The presented results of the unconfined compression testing of both the native joint cartilage tissues and potential substitute materials outlined the opportunity to measure the dissipation energy and thus to identify the initial mechanical deterioration symptoms and to introduce a better definition of material damage. Based on the analysis of measured specimen deformation, the intact and pathologically changed cartilage tissue can be distinguished and the differences revealed.
- 3 February 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1274-1277
Thermomechanical response of membrane-like MEMS component
- 3 February 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1274-1277
Thermomechanical response of membrane-like MEMS component