Bruno Samain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bruno Samain has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Valentijn R. N. Pauwels
Department of Civil Engineering Monash University Clayton Victoria Australia
2 shared publications Willem Defloor
Flemish Environmental Agency–Department Operational Water Management, Brussels, Belgium
2 shared publicationsBram V. A. Ferket
Laboratory of Hydrology and Water Management Ghent University Ghent Belgium
1 shared publication
Latest Publications
- Open Access
- 1 April 2012
- Published by American Meteorological Society in Journal of Hydrometeorology
- Vol. 13 (2) , 423-442
Continuous Time Series of Catchment-Averaged Sensible Heat Flux from a Large Aperture Scintillometer: Efficient Estimation of Stability Conditions and Importance of Fluxes under Stable Conditions
A large aperture scintillometer (LAS) observes the intensity of the atmospheric turbulence across large distances, which is related to the path-averaged sensible heat flux H. In this paper, two problems in the derivation of continuous series of H from LAS data are investigated and the importance of nighttime H fluxes is assessed. First, as an LAS is unable to determine the sign of H, the transition from unstable to stable conditions is evaluated in order to make continuous H series. Therefore, different algorithms to judge the atmospheric stability for an LAS installed over a distance of 9.5 km have been tested. The diurnal cycle of the refractive index structure parameter, , results in the best suitable, operational algorithm. A second issue is the humidity correction for LAS data, which is performed by using the Bowen ratio (β). As β is taken from ground-based measurements with data gaps, the number of resulting H values is reduced. Not including this humidity correction results in a marginal er...
- 1 April 2012
- Published by American Meteorological Society in Journal of Hydrometeorology
- Vol. 13 (2) , 423-442
Open AccessContinuous Time Series of Catchment-Averaged Sensible Heat Flux from a Large Aperture Scintillometer: Efficient Estimation of Stability Conditions and Importance of Fluxes under Stable Conditions
A large aperture scintillometer (LAS) observes the intensity of the atmospheric turbulence across large distances, which is related to the path-averaged sensible heat flux H. In this paper, two problems in the derivation of continuous series of H from LAS data are investigated and the importance of nighttime H fluxes is assessed. First, as an LAS is unable to determine the sign of H, the transition from unstable to stable conditions is evaluated in order to make continuous H series. Therefore, different algorithms to judge the atmospheric stability for an LAS installed over a distance of 9.5 km have been tested. The diurnal cycle of the refractive index structure parameter, , results in the best suitable, operational algorithm. A second issue is the humidity correction for LAS data, which is performed by using the Bowen ratio (β). As β is taken from ground-based measurements with data gaps, the number of resulting H values is reduced. Not including this humidity correction results in a marginal er...
- 26 May 2011
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 47 (5)
Estimation of catchment averaged sensible heat fluxes using a large aperture scintillometer
Evapotranspiration rates at the catchment scale are very difficult to quantify. One possible manner to continuously observe this variable could be the estimation of sensible heat fluxes (H) across large distances (in the order of kilometers) using a large aperture scintillometer (LAS), and inverting these observations into evapotranspiration rates, under the assumption that the LAS observations are representative for the entire catchment. The objective of this paper is to assess whether measured sensible heat fluxes from a LAS over a long distance (9.5 km) can be assumed to be valid for a 102.3 km2 heterogeneous catchment. Therefore, a fully process‐based water and energy balance model with a spatial resolution of 50 m has been thoroughly calibrated and validated for the Bellebeek catchment in Belgium. A footprint analysis has been performed. In general, the sensible heat fluxes from the LAS compared well with the modeled sensible heat fluxes within the footprint. Moreover, as the modeled H within the footprint has been found to be almost equal to the modeled catchment averaged H, it can be concluded that the scintillometer measurements over a distance of 9.5 km and an effective height of 68 m are representative for the entire catchment.
- 26 May 2011
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 47 (5)
Estimation of catchment averaged sensible heat fluxes using a large aperture scintillometer
Evapotranspiration rates at the catchment scale are very difficult to quantify. One possible manner to continuously observe this variable could be the estimation of sensible heat fluxes (H) across large distances (in the order of kilometers) using a large aperture scintillometer (LAS), and inverting these observations into evapotranspiration rates, under the assumption that the LAS observations are representative for the entire catchment. The objective of this paper is to assess whether measured sensible heat fluxes from a LAS over a long distance (9.5 km) can be assumed to be valid for a 102.3 km2 heterogeneous catchment. Therefore, a fully process‐based water and energy balance model with a spatial resolution of 50 m has been thoroughly calibrated and validated for the Bellebeek catchment in Belgium. A footprint analysis has been performed. In general, the sensible heat fluxes from the LAS compared well with the modeled sensible heat fluxes within the footprint. Moreover, as the modeled H within the footprint has been found to be almost equal to the modeled catchment averaged H, it can be concluded that the scintillometer measurements over a distance of 9.5 km and an effective height of 68 m are representative for the entire catchment.