AMAshraf Mozayani

Ashraf Mozayani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashraf Mozayani has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Anna T. Kelly

    Harris County Institute of Forensic Sciences, Toxicology Laboratory, 1885 Old Spanish Trail, Houston, Texas 77054

    2 shared publications
  • Warren C. Samms

    Harris County Institute of Forensic Sciences , Houston , Texas , United States

    2 shared publications
  • Crystal Arndt

    Harris County Institute of Forensic Sciences, Toxicology Laboratory, 1885 Old Spanish Trail, Houston, Texas 77054

    1 shared publication
  • Fessessework Guale

    Harris County Institute of Forensic Sciences, Toxicology Laboratory, Houston, Texas 77054, USA

    1 shared publication
  • Hsin-Hung Chen

    Harris County Institute of Forensic Sciences, Toxicology Laboratory, 1885 Old Spanish Trail, Houston, Texas 77054

    1 shared publication
  • Jeffrey P. Walterscheid

    Harris County Institute of Forensic Sciences, Toxicology Laboratory, 1885 Old Spanish Trail, Houston, Texas 77054

    1 shared publication

Latest Publications

  • Open Access

    Validation of LC–TOF-MS Screening for Drugs, Metabolites, and Collateral Compounds in Forensic Toxicology Specimens

    by Fessessework Guale, Shahriar Shahreza, Jeffrey P. Walterscheid, Hsin-Hung Chen, Crystal Arndt, Anna T. Kelly, Ashraf Mozayani

    Liquid chromatography time-of-flight mass spectrometry (LC–TOF-MS) analysis provides an expansive technique for identifying many known and unknown analytes. This study developed a screening method that utilizes automated solid-phase extraction to purify a wide array of analytes involving stimulants, benzodiazepines, opiates, muscle relaxants, hypnotics, antihistamines, antidepressants and newer synthetic “Spice/K2” cannabinoids and cathinone “bath salt” designer drugs. The extract was applied to LC–TOF-MS analysis, implementing a 13 min chromatography gradient with mobile phases of ammonium formate and methanol using positive mode electrospray. Several common drugs and metabolites can share the same mass and chemical formula among unrelated compounds, but they are structurally different. In this method, the LC–TOF-MS was able to resolve many isobaric compounds by accurate mass correlation within 15 ppm mass units and a narrow retention time interval of less than 10 s of separation. Drug recovery yields varied among spiked compounds, but resulted in overall robust area counts to deliver an average match score of 86 when compared to the retention time and mass of authentic standards. In summary, this method represents a rapid, enhanced screen for blood and urine specimens in postmortem, driving under the influence, and drug facilitated sexual assault forensic toxicology casework.


  • Considerations of Design and Implementation of a Paperless Forensic Laboratory

    by Warren C. Samms, Ashraf Mozayani

    While it is becoming increasingly popular for forensic laboratories to develop and implement paperless workflows, there remains a large void between the theoretical concept of a “paperless laboratory” and its actualization. There is currently no mechanism whereby laboratories may benefit from each other's successes and missteps in the planning or implementation phases of a workflow. In an effort to understand the variety of opinions within the forensic community with regards to paperless operations, and to see where viewpoints may converge on some of these issues, the Harris County Institute of Forensic Sciences (HCIFS), in conjunction with the National Forensic Science Technology Center (NFSTC), hosted a paperless focus group in early 2012. Approximately 20 participants were selected from forensic laboratory agencies within North America, and all were known to have solid paperless practices within their laboratory sections. Topics discussed during the one-and-a-half-day session included defining the term paperless, accreditation aspects, efficiency/automation, implementation strategies, staffing/training considerations, and document security. This article reflects the discussions and considerations by the participants within the focus group.

  • An Overview of Alcohol Testing and Interpretation in the 21st Century

    by Anna T. Kelly, Ashraf Mozayani

    Ethanol analysis is the most commonly carried out drug testing in a forensic toxicology laboratory. Determination of blood alcohol concentration (BAC) is needed in a multitude of situations, including in postmortem analysis, driving under the influence (DUI) and drug-facilitated sexual assault (DFSA) cases, workplace drug monitoring, and probation investigations. These analyses are carried out by direct measurement of ethanol concentrations as well as of metabolic by-products, such as ethyl glucuronide (EtG) and ethyl sulfate (EtS). This review article will discuss pharmacokinetics, including absorption, distribution, and elimination of ethanol, methods for the detection of ethanol, the effect of ethanol on human performance, the role of alcohol in injuries and fatalities, and information regarding the interactions that may occur between alcohol and other drugs. Finally, an explanation will be given on how to interpret alcohol levels as well as the extrapolation and calculation of blood alcohol levels at times prior to sample collection.


  • Analysis of Alprazolam by DART-TOF Mass Spectrometry in Counterfeit and Routine Drug Identification Cases

    by Warren C. Samms, Yongyi Julia Jiang, Mark D. Dixon, Stephen S. Houck, Ashraf Mozayani