Javier García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Javier García has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Zeev Zalevsky
Bar-Ilan University
6 shared publications- Vicente Micó
University of Valencia
5 shared publications Vicente Mico
AIDO, Technological Institute of Optics, Colour and Imaging, C/. Nicolás Copérnico, 7-13 Parc Tecnològic 46980 Paterna, Valencia, Spain
3 shared publications- Yevgeny Beiderman
Faculty of Electrical and Electronics Engineering, Holon Institute of Technology, Holon 5810201, Israel
3 shared publications - Zeev Zalevsky
Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
3 shared publications - Martin Sanz
Departamento de Óptica y de Optometría y Ciencias de la Visión, Facultad de Física, Universidad de Valencia, C/Doctor Moliner 50, 46100 Burjassot, Spain
2 shared publications
Latest Publications
- Open Access
- 22 September 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 335, 01002
1,000-fold amplification in time-holography phase metrology
Conventional interferometers provide uniform phase sensitivity across the measurement range. However, for applications involving small phase changes, amplifying the response within a specific phase range—at the expense of reduced sensitivity elsewhere—can be advantageous. A key example is the Gires-Tournois etalon, used in gravitational wave interferometers. In this work, we introduce an ultrasensitive phase measurement system based on time-holographic recording with a conventional Mach-Zehnder interferometer, operated near the intensity minimum at the dark output port. Phase fluctuations in the milliradian range around this point are converted into rad-sized dark output phases, with amplification factors exceeding 1,000. The adjustable imbalance between the interferometer arms controls this magnification, which is revealed by heterodyning the output with a frequency-shifted beam. Phase is digitally retrieved from the time-hologram using Fourier processing, with noise subtraction for correction. The system achieves phase sensitivities better than λ/3,000, enabling sub-nanometer precision for dimensional measurements. This versatile platform provides powerful tools for ultrasensitive phase measurements in a wide range of scientific and technological applications.
- 22 September 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 335, 01002
Open Access1,000-fold amplification in time-holography phase metrology
Conventional interferometers provide uniform phase sensitivity across the measurement range. However, for applications involving small phase changes, amplifying the response within a specific phase range—at the expense of reduced sensitivity elsewhere—can be advantageous. A key example is the Gires-Tournois etalon, used in gravitational wave interferometers. In this work, we introduce an ultrasensitive phase measurement system based on time-holographic recording with a conventional Mach-Zehnder interferometer, operated near the intensity minimum at the dark output port. Phase fluctuations in the milliradian range around this point are converted into rad-sized dark output phases, with amplification factors exceeding 1,000. The adjustable imbalance between the interferometer arms controls this magnification, which is revealed by heterodyning the output with a frequency-shifted beam. Phase is digitally retrieved from the time-hologram using Fourier processing, with noise subtraction for correction. The system achieves phase sensitivities better than λ/3,000, enabling sub-nanometer precision for dimensional measurements. This versatile platform provides powerful tools for ultrasensitive phase measurements in a wide range of scientific and technological applications.
- Open Access
Spatially Multiplexed Speckle on 1D Sensors for High-Speed 2D Sensing Applications
Speckle pattern-based remote vibration monitoring has recently become increasingly valuable in industrial, commercial, and medical applications. The dynamic and random nature of speckle patterns offers practical applications for imaging and measurement systems. The speckle pattern is an interference pattern generated by light scattered from a rough surface onto a remote plane. It is typically sensed using area scan cameras (2D), which are limited to framerates of 2–4 kHz and can only capture a small region of interest (ROI). In this work, we propose a technique that enables the capture of synthetic 2D speckle patterns using a 1D high-acquisition-rate sensor and a diffractive optical element (DOE) to produce image replicas. The multiple replicas are scanned by the 1D sensor simultaneously at different spatial positions. This method provides an ability to sense remote vibrations in all directions, contrary to the case with a simple 1D sensing system.
Open AccessSpatially Multiplexed Speckle on 1D Sensors for High-Speed 2D Sensing Applications
Speckle pattern-based remote vibration monitoring has recently become increasingly valuable in industrial, commercial, and medical applications. The dynamic and random nature of speckle patterns offers practical applications for imaging and measurement systems. The speckle pattern is an interference pattern generated by light scattered from a rough surface onto a remote plane. It is typically sensed using area scan cameras (2D), which are limited to framerates of 2–4 kHz and can only capture a small region of interest (ROI). In this work, we propose a technique that enables the capture of synthetic 2D speckle patterns using a 1D high-acquisition-rate sensor and a diffractive optical element (DOE) to produce image replicas. The multiple replicas are scanned by the 1D sensor simultaneously at different spatial positions. This method provides an ability to sense remote vibrations in all directions, contrary to the case with a simple 1D sensing system.
- Open Access
- 10 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 253
Fluholoscopy—Compact and Simple Platform Combining Fluorescence and Holographic Microscopy
The combination of different imaging modalities into single imaging platforms has a strong potential in biomedical sciences as it permits the analysis of complementary properties of the target sample. Here, we report on an extremely simple, cost-effective, and compact microscope platform for achieving simultaneous fluorescence and quantitative phase imaging modes with the capability of working in a single snapshot. It is based on the use of a single illumination wavelength to both excite the sample’s fluorescence and provide coherent illumination for phase imaging. After passing the microscope layout, the two imaging paths are separated using a bandpass filter, and the two imaging modes are simultaneously obtained using two digital cameras. We first present calibration and analysis of both fluorescence and phase imaging modalities working independently and, later on, experimental validation for the proposed common-path dual-mode imaging platform considering static (resolution test targets, fluorescent micro-beads, and water-suspended lab-made cultures) as well as dynamic (flowing fluorescent beads, human sperm cells, and live specimens from lab-made cultures) samples.
- 10 February 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (2) , 253
Open AccessFluholoscopy—Compact and Simple Platform Combining Fluorescence and Holographic Microscopy
The combination of different imaging modalities into single imaging platforms has a strong potential in biomedical sciences as it permits the analysis of complementary properties of the target sample. Here, we report on an extremely simple, cost-effective, and compact microscope platform for achieving simultaneous fluorescence and quantitative phase imaging modes with the capability of working in a single snapshot. It is based on the use of a single illumination wavelength to both excite the sample’s fluorescence and provide coherent illumination for phase imaging. After passing the microscope layout, the two imaging paths are separated using a bandpass filter, and the two imaging modes are simultaneously obtained using two digital cameras. We first present calibration and analysis of both fluorescence and phase imaging modalities working independently and, later on, experimental validation for the proposed common-path dual-mode imaging platform considering static (resolution test targets, fluorescent micro-beads, and water-suspended lab-made cultures) as well as dynamic (flowing fluorescent beads, human sperm cells, and live specimens from lab-made cultures) samples.
- Open Access
Multi-Illumination Single-Holographic-Exposure Lensless Fresnel (MISHELF) Microscopy: Principles and Biomedical Applications
Lensless holographic microscopy (LHM) comes out as a promising label-free technique since it supplies high-quality imaging and adaptive magnification in a lens-free, compact and cost-effective way. Compact sizes and reduced prices of LHMs make them a perfect instrument for point-of-care diagnosis and increase their usability in limited-resource laboratories, remote areas, and poor countries. LHM can provide excellent intensity and phase imaging when the twin image is removed. In that sense, multi-illumination single-holographic-exposure lensless Fresnel (MISHELF) microscopy appears as a single-shot and phase-retrieved imaging technique employing multiple illumination/detection channels and a fast-iterative phase-retrieval algorithm. In this contribution, we review MISHELF microscopy through the description of the principles, the analysis of the performance, the presentation of the microscope prototypes and the inclusion of the main biomedical applications reported so far.
Open AccessMulti-Illumination Single-Holographic-Exposure Lensless Fresnel (MISHELF) Microscopy: Principles and Biomedical Applications
Lensless holographic microscopy (LHM) comes out as a promising label-free technique since it supplies high-quality imaging and adaptive magnification in a lens-free, compact and cost-effective way. Compact sizes and reduced prices of LHMs make them a perfect instrument for point-of-care diagnosis and increase their usability in limited-resource laboratories, remote areas, and poor countries. LHM can provide excellent intensity and phase imaging when the twin image is removed. In that sense, multi-illumination single-holographic-exposure lensless Fresnel (MISHELF) microscopy appears as a single-shot and phase-retrieved imaging technique employing multiple illumination/detection channels and a fast-iterative phase-retrieval algorithm. In this contribution, we review MISHELF microscopy through the description of the principles, the analysis of the performance, the presentation of the microscope prototypes and the inclusion of the main biomedical applications reported so far.
- 8 November 2010
- Published by Springer Nature
- p. 145-167
Quantitative Phase Imaging in Microscopy Using a Spatial Light Modulator
- 8 November 2010
- Published by Springer Nature
- p. 145-167
Quantitative Phase Imaging in Microscopy Using a Spatial Light Modulator
- 8 November 2010
- Published by Springer Nature
- p. 347-367
Three-Dimensional Mapping and Ranging of Objects Using Speckle Pattern Analysis
- 8 November 2010
- Published by Springer Nature
- p. 347-367
Three-Dimensional Mapping and Ranging of Objects Using Speckle Pattern Analysis
- 8 November 2010
- Published by Springer Nature
- p. 269-293
Coherent Microscopy for 3-D Movement Monitoring and Super-Resolved Imaging
- 8 November 2010
- Published by Springer Nature
- p. 269-293
Coherent Microscopy for 3-D Movement Monitoring and Super-Resolved Imaging
- 4 May 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (10) , 1492-1494
Phase-shifting Gabor holography
We present a modified Gabor-like setup able to recover the complex amplitude distribution of the object wavefront from a set of inline recorded holograms. The proposed configuration is characterized by the insertion of a condenser lens and a spatial light modulator (SLM) into the classical Gabor configuration. The phase shift is introduced by the SLM that modulates the central spot (dc term) in an intermediate plane, without an additional reference beam. Experimental results validate the proposed method and produce superior results to the Gabor method.
- 4 May 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (10) , 1492-1494
Phase-shifting Gabor holography
We present a modified Gabor-like setup able to recover the complex amplitude distribution of the object wavefront from a set of inline recorded holograms. The proposed configuration is characterized by the insertion of a condenser lens and a spatial light modulator (SLM) into the classical Gabor configuration. The phase shift is introduced by the SLM that modulates the central spot (dc term) in an intermediate plane, without an additional reference beam. Experimental results validate the proposed method and produce superior results to the Gabor method.
- 26 May 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (16) , 3032-3040
Three-dimensional mapping and range measurement by means of projected speckle patterns
We present a novel approach for three-dimensional (3D) measurements that includes the projection of coherent light through ground glass. Such a projection generates random speckle patterns on the object or on the camera, depending if the configuration is transmissive or reflective. In both cases the spatially random patterns are seen by the sensor. Different spatially random patterns are generated at different planes. The patterns are highly random and not correlated. This low correlation between different patterns is used for both 3D mapping of objects and range finding.
- 26 May 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (16) , 3032-3040
Three-dimensional mapping and range measurement by means of projected speckle patterns
We present a novel approach for three-dimensional (3D) measurements that includes the projection of coherent light through ground glass. Such a projection generates random speckle patterns on the object or on the camera, depending if the configuration is transmissive or reflective. In both cases the spatially random patterns are seen by the sensor. Different spatially random patterns are generated at different planes. The patterns are highly random and not correlated. This low correlation between different patterns is used for both 3D mapping of objects and range finding.
- 11 March 2008
- Published by Wiley in Imaging & Microscopy
- Vol. 10 (1) , 38-39
Superresolved Holographic Microscopy
- 11 March 2008
- Published by Wiley in Imaging & Microscopy
- Vol. 10 (1) , 38-39
Superresolved Holographic Microscopy