Thomas K. Aldrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas K. Aldrich has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Anna Nolan
Fire Department of the City of New York, Bureau of Health Services, Brooklyn, New York
4 shared publications - Charles B. Hall
Department of Epidemiology and Population Health, Albert Einstein College of Medicine, Bronx, USA
4 shared publications - Hillel W. Cohen
Department of Epidemiology and Population Health, Albert Einstein College of Medicine, Bronx, New York; and
3 shared publications David J. Prezant
Fire Department of the City of New York, Bureau of Health Services, Brooklyn, NY
2 shared publications- David J. Prezant
Department of Medicine, Montefiore Medical Center , Bronx, NY
2 shared publications Kerry J. Kelly
Fire Department of the City of New York, Bureau of Health Services, Brooklyn, NY
2 shared publications
Latest Publications
- 1 February 2018
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 15 (2) , 173-183
Blood Leukocyte Concentrations, FEV1 Decline, and Airflow Limitation. A 15-Year Longitudinal Study of World Trade Center–exposed Firefighters
Rationale: Rescue/recovery work at the World Trade Center disaster site (WTC) caused a proximate decline in lung function in Fire Department of the City of New York firefighters. A subset of this cohort experienced an accelerated rate of lung function decline over 15 years of post–September 11, 2001 (9/11) follow-up. Objectives: To determine if early postexposure blood leukocyte concentrations are biomarkers for subsequent FEV1 decline and incident airflow limitation. Methods: Individual rates of forced expiratory volume in 1 second (FEV1) change were calculated for 9,434 firefighters using 88,709 spirometric measurements taken between September 11, 2001, and September 10, 2016. We categorized FEV1 change rates into three trajectories: accelerated FEV1 decline (FEV1 loss >64 ml/yr), expected FEV1 decline (FEV1 loss between 0 and 64 ml/yr), and improved FEV1 (positive rate of change >0 ml/yr). Occurrence of FEV1/FVC less than 0.70 after 9/11 defined incident airflow limitation. Using regression models, we assessed associations of post-9/11 blood eosinophil and neutrophil concentrations with subsequent FEV1 decline and airflow limitation, adjusted for age, race, smoking, height, WTC exposure level, weight change, and baseline lung function. Results: Accelerated FEV1 decline occurred in 12.7% of participants (1,199 of 9,434), whereas post-9/11 FEV1 improvement occurred in 8.3% (780 of 9,434). Higher blood eosinophil and neutrophil concentrations were each associated with accelerated FEV1 decline after adjustment for covariates (odds ratio [OR], 1.10 per 100 eosinophils/μl; 95% confidence interval [CI], 1.05–1.15; and OR, 1.10 per 1,000 neutrophils/μl; 95% CI, 1.05–1.15, respectively). Multivariable-adjusted linear regression models showed that a higher blood neutrophil concentration was associated with a faster rate of FEV1 decline (1.14 ml/yr decline per 1,000 neutrophils/μl; 95% CI, 0.69–1.60 ml/yr; P < 0.001). Higher blood eosinophil concentrations were associated with a faster rate of FEV1 decline in ever-smokers (1.46 ml/yr decline per 100 eosinophils/μl; 95% CI, 0.65–2.26 ml/yr; P < 0.001) but not in never-smokers (P for interaction = 0.004). Higher eosinophil concentrations were also associated with incident airflow limitation (adjusted hazard ratio, 1.10 per 100 eosinophils/μl; 95% CI, 1.04–1.15). Compared with the expected FEV1 decline group, individuals experiencing accelerated FEV1 decline were more likely to have incident airflow limitation (adjusted OR, 4.12; 95% CI, 3.30–5.14). Conclusions: Higher post-9/11 blood neutrophil and eosinophil concentrations were associated with subsequent accelerated FEV1 decline in WTC-exposed firefighters. Both higher blood eosinophil concentrations and accelerated FEV1 decline were associated with incident airflow limitation in WTC-exposed firefighters.
- 1 February 2018
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 15 (2) , 173-183
Blood Leukocyte Concentrations, FEV1 Decline, and Airflow Limitation. A 15-Year Longitudinal Study of World Trade Center–exposed Firefighters
Rationale: Rescue/recovery work at the World Trade Center disaster site (WTC) caused a proximate decline in lung function in Fire Department of the City of New York firefighters. A subset of this cohort experienced an accelerated rate of lung function decline over 15 years of post–September 11, 2001 (9/11) follow-up. Objectives: To determine if early postexposure blood leukocyte concentrations are biomarkers for subsequent FEV1 decline and incident airflow limitation. Methods: Individual rates of forced expiratory volume in 1 second (FEV1) change were calculated for 9,434 firefighters using 88,709 spirometric measurements taken between September 11, 2001, and September 10, 2016. We categorized FEV1 change rates into three trajectories: accelerated FEV1 decline (FEV1 loss >64 ml/yr), expected FEV1 decline (FEV1 loss between 0 and 64 ml/yr), and improved FEV1 (positive rate of change >0 ml/yr). Occurrence of FEV1/FVC less than 0.70 after 9/11 defined incident airflow limitation. Using regression models, we assessed associations of post-9/11 blood eosinophil and neutrophil concentrations with subsequent FEV1 decline and airflow limitation, adjusted for age, race, smoking, height, WTC exposure level, weight change, and baseline lung function. Results: Accelerated FEV1 decline occurred in 12.7% of participants (1,199 of 9,434), whereas post-9/11 FEV1 improvement occurred in 8.3% (780 of 9,434). Higher blood eosinophil and neutrophil concentrations were each associated with accelerated FEV1 decline after adjustment for covariates (odds ratio [OR], 1.10 per 100 eosinophils/μl; 95% confidence interval [CI], 1.05–1.15; and OR, 1.10 per 1,000 neutrophils/μl; 95% CI, 1.05–1.15, respectively). Multivariable-adjusted linear regression models showed that a higher blood neutrophil concentration was associated with a faster rate of FEV1 decline (1.14 ml/yr decline per 1,000 neutrophils/μl; 95% CI, 0.69–1.60 ml/yr; P < 0.001). Higher blood eosinophil concentrations were associated with a faster rate of FEV1 decline in ever-smokers (1.46 ml/yr decline per 100 eosinophils/μl; 95% CI, 0.65–2.26 ml/yr; P < 0.001) but not in never-smokers (P for interaction = 0.004). Higher eosinophil concentrations were also associated with incident airflow limitation (adjusted hazard ratio, 1.10 per 100 eosinophils/μl; 95% CI, 1.04–1.15). Compared with the expected FEV1 decline group, individuals experiencing accelerated FEV1 decline were more likely to have incident airflow limitation (adjusted OR, 4.12; 95% CI, 3.30–5.14). Conclusions: Higher post-9/11 blood neutrophil and eosinophil concentrations were associated with subsequent accelerated FEV1 decline in WTC-exposed firefighters. Both higher blood eosinophil concentrations and accelerated FEV1 decline were associated with incident airflow limitation in WTC-exposed firefighters.
- 1 November 2002
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 30 (10) , 1291-1298
Length-Normalized Pulse Photoplethysmography: A Noninvasive Method to Measure Blood Hemoglobin, Bronx, NY
To determine whether blood hemoglobin concentration ([Hb]) could be measured noninvasively as the ratio of pulsatile changes in attenuation (absorbance plus scatter) of light (D) across a body part to changes in light path length (l), we measured transmission of near-infrared light (905±10 nm) through a finger, using a modified pulse oximeter, and simultaneously monitored fingertip diameter, using a sonomicrometer. In 25 subjects with [Hb] ranging from 3.1 to 18.2 gm/dl, and with normal oxygenation, average D/l ratio over 30–60 s correlated strongly with [Hb] measured by Coulter counter (r=0.84, p≪0.001), though with considerable scatter, with absolute value of differences averaging 17% of the mean. Using 12 gm/dl and 0.75 mm-1 as the lower limits of normal for [Hb] and D/l, respectively, two of nine normals had low (D/l) (78% specificity), and only one of 16 anemic subjects had borderline normal (D/l) (94%–100% sensitivity). The positive predictive value of a low (D/l) was 88% and the negative predictive value was 87.5%. With further development, this technique may reduce the need for phlebotomy, thereby reducing risks and costs and improving the experience of being a patient. © 2002 Biomedical Engineering Society. PAC2002: 8763Lk, 8714Ee
- 1 November 2002
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 30 (10) , 1291-1298
Length-Normalized Pulse Photoplethysmography: A Noninvasive Method to Measure Blood Hemoglobin, Bronx, NY
To determine whether blood hemoglobin concentration ([Hb]) could be measured noninvasively as the ratio of pulsatile changes in attenuation (absorbance plus scatter) of light (D) across a body part to changes in light path length (l), we measured transmission of near-infrared light (905±10 nm) through a finger, using a modified pulse oximeter, and simultaneously monitored fingertip diameter, using a sonomicrometer. In 25 subjects with [Hb] ranging from 3.1 to 18.2 gm/dl, and with normal oxygenation, average D/l ratio over 30–60 s correlated strongly with [Hb] measured by Coulter counter (r=0.84, p≪0.001), though with considerable scatter, with absolute value of differences averaging 17% of the mean. Using 12 gm/dl and 0.75 mm-1 as the lower limits of normal for [Hb] and D/l, respectively, two of nine normals had low (D/l) (78% specificity), and only one of 16 anemic subjects had borderline normal (D/l) (94%–100% sensitivity). The positive predictive value of a low (D/l) was 88% and the negative predictive value was 87.5%. With further development, this technique may reduce the need for phlebotomy, thereby reducing risks and costs and improving the experience of being a patient. © 2002 Biomedical Engineering Society. PAC2002: 8763Lk, 8714Ee