Amer M. Johri has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Jasjit S. Suri
Department of ECE, Idaho State University, Pocatello, ID 83209, USA
4 shared publications - Luca Saba
Department of Radiology, Azienda Ospedaliero-Universitaria (A.O.U.) di Cagliari, 09124 Cagliari, Italy
4 shared publications - John R. Laird
Heart and Vascular Institute, Adventist Health St. Helena, St. Helena, CA 94574, USA
3 shared publications - Andrew Nicolaides
Vascular Screening and Diagnostic Centre and University of Nicosia Medical School, 2408 Nicosia, Cyprus
2 shared publications - Esma R. Isenovic
VINČA Institute of Nuclear Sciences
2 shared publications - Gavino Faa
Department of Medical Sciences and Public Health, University of Cagliari, 09124 Cagliari, Italy
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2538
Twelve Fused Models by Fusing Four Types of Transformer-Based Tuners on Three Base UNet Architectures for Carotid Wall Segmentation and Plaque Burden/Intima-Media Thickness Measurements in Ultrasound Scans: A Scientific Validation Study
Background/Objectives: UNet-based models dominate medical image segmentation. Transformers have been added as an internal variant to these UNet-based architectures to improve feature learning. However, they have limitations in generalization and computational efficiency. Motivated by this idea, we have designed a two-stage novel hybrid segmentation framework, where tuners are added in cascade to the base architectures. Methods: Three sets of base UNets were designed, namely: B1: UNet1p, B2: UNet2p, and B3:UNet3p, and four sets of transformer-based tuners were designed, namely: T1:Transformer-augmented UNet, T2: Attention-guided UNet, T3: Swin Transformer-based UNet, and T4: Pyramid-based network, leading to 12 fused systems that combine three base UNets and four Tuners, namely: F1: B1 + T1, F2: B1 + T2, F3: B1 + T3, F4: B1 + T4; F5: B2 + T1, F6: B2 + T2, F7: B2 + T3, F8: B2 + T4, F9: B3 + T1, F10: B3 + T2, F11: B3 + T3, F12: B3 + T4. Results: The two-hybrid segmentation models are more effective and reliable than the single-stage UNet architecture. B3 + T4 achieved a Dice of 94.14% and Jaccard of 88.7%, surpassing prior baselines by 4.2% and 6.8%. It reduced cIMTE to 0.014 mm, a 36% improvement and the lowest reported to date, with cLIE and cMAE errors lowered by 40%. Conclusions: All 12 hybrid automated transformer-based models are highly accurate and reliable for wall segmentation in carotid ultrasound; they are a powerful paradigm for cardiovascular risk.
- 12 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2538
Open AccessTwelve Fused Models by Fusing Four Types of Transformer-Based Tuners on Three Base UNet Architectures for Carotid Wall Segmentation and Plaque Burden/Intima-Media Thickness Measurements in Ultrasound Scans: A Scientific Validation Study
Background/Objectives: UNet-based models dominate medical image segmentation. Transformers have been added as an internal variant to these UNet-based architectures to improve feature learning. However, they have limitations in generalization and computational efficiency. Motivated by this idea, we have designed a two-stage novel hybrid segmentation framework, where tuners are added in cascade to the base architectures. Methods: Three sets of base UNets were designed, namely: B1: UNet1p, B2: UNet2p, and B3:UNet3p, and four sets of transformer-based tuners were designed, namely: T1:Transformer-augmented UNet, T2: Attention-guided UNet, T3: Swin Transformer-based UNet, and T4: Pyramid-based network, leading to 12 fused systems that combine three base UNets and four Tuners, namely: F1: B1 + T1, F2: B1 + T2, F3: B1 + T3, F4: B1 + T4; F5: B2 + T1, F6: B2 + T2, F7: B2 + T3, F8: B2 + T4, F9: B3 + T1, F10: B3 + T2, F11: B3 + T3, F12: B3 + T4. Results: The two-hybrid segmentation models are more effective and reliable than the single-stage UNet architecture. B3 + T4 achieved a Dice of 94.14% and Jaccard of 88.7%, surpassing prior baselines by 4.2% and 6.8%. It reduced cIMTE to 0.014 mm, a 36% improvement and the lowest reported to date, with cLIE and cMAE errors lowered by 40%. Conclusions: All 12 hybrid automated transformer-based models are highly accurate and reliable for wall segmentation in carotid ultrasound; they are a powerful paradigm for cardiovascular risk.
- Open Access
- 28 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1894
Cardiovascular Disease Risk Stratification Using Hybrid Deep Learning Paradigm: First of Its Kind on Canadian Trial Data
Background: The risk of cardiovascular disease (CVD) has traditionally been predicted via the assessment of carotid plaques. In the proposed study, AtheroEdge™ 3.0HDL (AtheroPoint™, Roseville, CA, USA) was designed to demonstrate how well the features obtained from carotid plaques determine the risk of CVD. We hypothesize that hybrid deep learning (HDL) will outperform unidirectional deep learning, bidirectional deep learning, and machine learning (ML) paradigms. Methodology: 500 people who had undergone targeted carotid B-mode ultrasonography and coronary angiography were included in the proposed study. ML feature selection was carried out using three different methods, namely principal component analysis (PCA) pooling, the chi-square test (CST), and the random forest regression (RFR) test. The unidirectional and bidirectional deep learning models were trained, and then six types of novel HDL-based models were designed for CVD risk stratification. The AtheroEdge™ 3.0HDL was scientifically validated using seen and unseen datasets while the reliability and statistical tests were conducted using CST along with p-value significance. The performance of AtheroEdge™ 3.0HDL was evaluated by measuring the p-value and area-under-the-curve for both seen and unseen data. Results: The HDL system showed an improvement of 30.20% (0.954 vs. 0.702) over the ML system using the seen datasets. The ML feature extraction analysis showed 70% of common features among all three methods. The generalization of AtheroEdge™ 3.0HDL showed less than 1% (p-value < 0.001) difference between seen and unseen data, complying with regulatory standards. Conclusions: The hypothesis for AtheroEdge™ 3.0HDL was scientifically validated, and the model was tested for reliability and stability and is further adaptable clinically.
- 28 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1894
Open AccessCardiovascular Disease Risk Stratification Using Hybrid Deep Learning Paradigm: First of Its Kind on Canadian Trial Data
Background: The risk of cardiovascular disease (CVD) has traditionally been predicted via the assessment of carotid plaques. In the proposed study, AtheroEdge™ 3.0HDL (AtheroPoint™, Roseville, CA, USA) was designed to demonstrate how well the features obtained from carotid plaques determine the risk of CVD. We hypothesize that hybrid deep learning (HDL) will outperform unidirectional deep learning, bidirectional deep learning, and machine learning (ML) paradigms. Methodology: 500 people who had undergone targeted carotid B-mode ultrasonography and coronary angiography were included in the proposed study. ML feature selection was carried out using three different methods, namely principal component analysis (PCA) pooling, the chi-square test (CST), and the random forest regression (RFR) test. The unidirectional and bidirectional deep learning models were trained, and then six types of novel HDL-based models were designed for CVD risk stratification. The AtheroEdge™ 3.0HDL was scientifically validated using seen and unseen datasets while the reliability and statistical tests were conducted using CST along with p-value significance. The performance of AtheroEdge™ 3.0HDL was evaluated by measuring the p-value and area-under-the-curve for both seen and unseen data. Results: The HDL system showed an improvement of 30.20% (0.954 vs. 0.702) over the ML system using the seen datasets. The ML feature extraction analysis showed 70% of common features among all three methods. The generalization of AtheroEdge™ 3.0HDL showed less than 1% (p-value < 0.001) difference between seen and unseen data, complying with regulatory standards. Conclusions: The hypothesis for AtheroEdge™ 3.0HDL was scientifically validated, and the model was tested for reliability and stability and is further adaptable clinically.
- Open Access
- 16 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 722
A Powerful Paradigm for Cardiovascular Risk Stratification Using Multiclass, Multi-Label, and Ensemble-Based Machine Learning Paradigms: A Narrative Review
Background and Motivation: Cardiovascular disease (CVD) causes the highest mortality globally. With escalating healthcare costs, early non-invasive CVD risk assessment is vital. Conventional methods have shown poor performance compared to more recent and fast-evolving Artificial Intelligence (AI) methods. The proposed study reviews the three most recent paradigms for CVD risk assessment, namely multiclass, multi-label, and ensemble-based methods in (i) office-based and (ii) stress-test laboratories. Methods: A total of 265 CVD-based studies were selected using the preferred reporting items for systematic reviews and meta-analyses (PRISMA) model. Due to its popularity and recent development, the study analyzed the above three paradigms using machine learning (ML) frameworks. We review comprehensively these three methods using attributes, such as architecture, applications, pro-and-cons, scientific validation, clinical evaluation, and AI risk-of-bias (RoB) in the CVD framework. These ML techniques were then extended under mobile and cloud-based infrastructure. Findings: Most popular biomarkers used were office-based, laboratory-based, image-based phenotypes, and medication usage. Surrogate carotid scanning for coronary artery risk prediction had shown promising results. Ground truth (GT) selection for AI-based training along with scientific and clinical validation is very important for CVD stratification to avoid RoB. It was observed that the most popular classification paradigm is multiclass followed by the ensemble, and multi-label. The use of deep learning techniques in CVD risk stratification is in a very early stage of development. Mobile and cloud-based AI technologies are more likely to be the future. Conclusions: AI-based methods for CVD risk assessment are most promising and successful. Choice of GT is most vital in AI-based models to prevent the RoB. The amalgamation of image-based strategies with conventional risk factors provides the highest stability when using the three CVD paradigms in non-cloud and cloud-based frameworks.
- 16 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 722
Open AccessA Powerful Paradigm for Cardiovascular Risk Stratification Using Multiclass, Multi-Label, and Ensemble-Based Machine Learning Paradigms: A Narrative Review
Background and Motivation: Cardiovascular disease (CVD) causes the highest mortality globally. With escalating healthcare costs, early non-invasive CVD risk assessment is vital. Conventional methods have shown poor performance compared to more recent and fast-evolving Artificial Intelligence (AI) methods. The proposed study reviews the three most recent paradigms for CVD risk assessment, namely multiclass, multi-label, and ensemble-based methods in (i) office-based and (ii) stress-test laboratories. Methods: A total of 265 CVD-based studies were selected using the preferred reporting items for systematic reviews and meta-analyses (PRISMA) model. Due to its popularity and recent development, the study analyzed the above three paradigms using machine learning (ML) frameworks. We review comprehensively these three methods using attributes, such as architecture, applications, pro-and-cons, scientific validation, clinical evaluation, and AI risk-of-bias (RoB) in the CVD framework. These ML techniques were then extended under mobile and cloud-based infrastructure. Findings: Most popular biomarkers used were office-based, laboratory-based, image-based phenotypes, and medication usage. Surrogate carotid scanning for coronary artery risk prediction had shown promising results. Ground truth (GT) selection for AI-based training along with scientific and clinical validation is very important for CVD stratification to avoid RoB. It was observed that the most popular classification paradigm is multiclass followed by the ensemble, and multi-label. The use of deep learning techniques in CVD risk stratification is in a very early stage of development. Mobile and cloud-based AI technologies are more likely to be the future. Conclusions: AI-based methods for CVD risk assessment are most promising and successful. Choice of GT is most vital in AI-based models to prevent the RoB. The amalgamation of image-based strategies with conventional risk factors provides the highest stability when using the three CVD paradigms in non-cloud and cloud-based frameworks.
- Open Access
- 2 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2257
Unseen Artificial Intelligence—Deep Learning Paradigm for Segmentation of Low Atherosclerotic Plaque in Carotid Ultrasound: A Multicenter Cardiovascular Study
Background: The early detection of carotid wall plaque is recommended in the prevention of cardiovascular disease (CVD) in moderate-risk patients. Previous techniques for B-mode carotid atherosclerotic wall plaque segmentation used artificial intelligence (AI) methods on monoethnic databases, where training and testing are from the “same” ethnic group (“Seen AI”). Therefore, the versatility of the system is questionable. This is the first study of its kind that uses the “Unseen AI” paradigm where training and testing are from “different” ethnic groups. We hypothesized that deep learning (DL) models should perform in 10% proximity between “Unseen AI” and “Seen AI”. Methodology: Two cohorts from multi-ethnic groups (330 Japanese and 300 Hong Kong (HK)) were used for the validation of our hypothesis. We used a four-layered UNet architecture for the segmentation of the atherosclerotic wall with low plaque. “Unseen AI” (training: Japanese, testing: HK or vice versa) and “Seen AI” experiments (single ethnicity or mixed ethnicity) were performed. Evaluation was conducted by measuring the wall plaque area. Statistical tests were conducted for its stability and reliability. Results: When using the UNet DL architecture, the “Unseen AI” pair one (Training: 330 Japanese and Testing: 300 HK), the mean accuracy, dice-similarity, and correlation-coefficient were 98.55, 78.38, and 0.80 (p < 0.0001), respectively, while for “Unseen AI” pair two (Training: 300 HK and Testing: 330 Japanese), these were 98.67, 82.49, and 0.87 (p < 0.0001), respectively. Using “Seen AI”, the same parameters were 99.01, 86.89 and 0.92 (p < 0.0001), respectively. Conclusion: We demonstrated that “Unseen AI” was in close proximity (<10%) to “Seen AI”, validating our DL model for low atherosclerotic wall plaque segmentation. The online system runs < 1 s.
- 2 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2257
Open AccessUnseen Artificial Intelligence—Deep Learning Paradigm for Segmentation of Low Atherosclerotic Plaque in Carotid Ultrasound: A Multicenter Cardiovascular Study
Background: The early detection of carotid wall plaque is recommended in the prevention of cardiovascular disease (CVD) in moderate-risk patients. Previous techniques for B-mode carotid atherosclerotic wall plaque segmentation used artificial intelligence (AI) methods on monoethnic databases, where training and testing are from the “same” ethnic group (“Seen AI”). Therefore, the versatility of the system is questionable. This is the first study of its kind that uses the “Unseen AI” paradigm where training and testing are from “different” ethnic groups. We hypothesized that deep learning (DL) models should perform in 10% proximity between “Unseen AI” and “Seen AI”. Methodology: Two cohorts from multi-ethnic groups (330 Japanese and 300 Hong Kong (HK)) were used for the validation of our hypothesis. We used a four-layered UNet architecture for the segmentation of the atherosclerotic wall with low plaque. “Unseen AI” (training: Japanese, testing: HK or vice versa) and “Seen AI” experiments (single ethnicity or mixed ethnicity) were performed. Evaluation was conducted by measuring the wall plaque area. Statistical tests were conducted for its stability and reliability. Results: When using the UNet DL architecture, the “Unseen AI” pair one (Training: 330 Japanese and Testing: 300 HK), the mean accuracy, dice-similarity, and correlation-coefficient were 98.55, 78.38, and 0.80 (p < 0.0001), respectively, while for “Unseen AI” pair two (Training: 300 HK and Testing: 330 Japanese), these were 98.67, 82.49, and 0.87 (p < 0.0001), respectively. Using “Seen AI”, the same parameters were 99.01, 86.89 and 0.92 (p < 0.0001), respectively. Conclusion: We demonstrated that “Unseen AI” was in close proximity (<10%) to “Seen AI”, validating our DL model for low atherosclerotic wall plaque segmentation. The online system runs < 1 s.
- 1 March 2014
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 27 (3) , 302-309
Development and Evaluation of Methodologies for Teaching Focused Cardiac Ultrasound Skills to Medical Students
- 1 March 2014
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 27 (3) , 302-309
Development and Evaluation of Methodologies for Teaching Focused Cardiac Ultrasound Skills to Medical Students
- Open Access
- 1 January 2012
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 3 (2) , 73-79-79
Quality Assessment in Dobutamine Stress Echocardiography: What are the Clinical Predictors Associated With a Non-Diagnostic Test?
Background: Non-diagnostic dobutamine stress echocardiography (ndDSE, failure to achieve 85% of maximal predicted heart rate (HR) without evidence of inducible ischemia) is an important limitation affecting quality of DSE testing. The objectives of this study were to identify the clinical variables associated with a non-diagnostic Dobutamine Stress Echocardiogram (ndDSE) and further evaluate the patterns of subsequent testing for myocardial ischemia. Methods: Consecutive DSEs over a 17 month period (January 2008 to June 2009) were studied. Baseline demographics, medical history, and vital signs were collected. Subsequent testing was determined for up to 6 months after the initial DSE. Univariate and multivariate logistic regression analysis was performed to identify clinical factors associated with ndDSE. Results: Of 467 total DSE, 314 (67%) were negative for ischemia, 69 (15%) were positive, and 84 (18%) were ndDSE. Of those recommended for further nuclear MPI testing 12 (14%) had an ndDSE compared to 16 (4%) patients with a diagnostic DSE (P = 0.001). Fifty percent of the ndDSE nuclear MPI tests were positive for ischemia. In the univariate analysis, Diabetes Mellitus (DM; P = 0.003), calcium channel antagonist (CCA) use (P = 0.047), Hypertension (HTN; P = 0.06), low baseline HR (P < 0.001), and younger age group (P = 0.02) were predictive of ndDSE. Of these, all except CCA use remained independent predictors of ndDSE in multivariate analysis. A 4 variable model for predicting ndDSE was developed from the multivariate logistic regression displayed in Table 1 (age and baseline HR were categorized and scored 0-2; DM and HTN were scored as 0 (absent) or 1 (present)). Figure 2 demonstrates how risk of ndDSE correlated with a higher score, with each increment having an odds ratio of 2.1 (P < 0.001). Conclusions: DM, HTN, younger age, and lower baseline HR affect the quality of DSE testing, resulting in non-diagnostic tests. A model combining these factors can identify patients most likely to have this outcome. Identification of this cohort may improve referral patterns and improve the quality of stress testing. doi:10.4021/cr154w
- 1 January 2012
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 3 (2) , 73-79-79
Open AccessQuality Assessment in Dobutamine Stress Echocardiography: What are the Clinical Predictors Associated With a Non-Diagnostic Test?
Background: Non-diagnostic dobutamine stress echocardiography (ndDSE, failure to achieve 85% of maximal predicted heart rate (HR) without evidence of inducible ischemia) is an important limitation affecting quality of DSE testing. The objectives of this study were to identify the clinical variables associated with a non-diagnostic Dobutamine Stress Echocardiogram (ndDSE) and further evaluate the patterns of subsequent testing for myocardial ischemia. Methods: Consecutive DSEs over a 17 month period (January 2008 to June 2009) were studied. Baseline demographics, medical history, and vital signs were collected. Subsequent testing was determined for up to 6 months after the initial DSE. Univariate and multivariate logistic regression analysis was performed to identify clinical factors associated with ndDSE. Results: Of 467 total DSE, 314 (67%) were negative for ischemia, 69 (15%) were positive, and 84 (18%) were ndDSE. Of those recommended for further nuclear MPI testing 12 (14%) had an ndDSE compared to 16 (4%) patients with a diagnostic DSE (P = 0.001). Fifty percent of the ndDSE nuclear MPI tests were positive for ischemia. In the univariate analysis, Diabetes Mellitus (DM; P = 0.003), calcium channel antagonist (CCA) use (P = 0.047), Hypertension (HTN; P = 0.06), low baseline HR (P < 0.001), and younger age group (P = 0.02) were predictive of ndDSE. Of these, all except CCA use remained independent predictors of ndDSE in multivariate analysis. A 4 variable model for predicting ndDSE was developed from the multivariate logistic regression displayed in Table 1 (age and baseline HR were categorized and scored 0-2; DM and HTN were scored as 0 (absent) or 1 (present)). Figure 2 demonstrates how risk of ndDSE correlated with a higher score, with each increment having an odds ratio of 2.1 (P < 0.001). Conclusions: DM, HTN, younger age, and lower baseline HR affect the quality of DSE testing, resulting in non-diagnostic tests. A model combining these factors can identify patients most likely to have this outcome. Identification of this cohort may improve referral patterns and improve the quality of stress testing. doi:10.4021/cr154w
- 19 August 2011
- Published by Wiley in Echocardiography
- Vol. 28 (9) , 1035-1040
Quadricuspid Aortic Valve: A Report of 12 Cases and a Review of the Literature
Quadricuspid aortic valve (QAV) is rare and its diagnosis, clinical course, and management are less well defined relative to other aortic valve abnormalities. Advances in diagnostic imaging, notably in ultrasound, have increased clinical awareness of this anomaly and prompted this review of our experience with 12 new patients and a compilation of previously reported patients to further characterize this condition. (Echocardiography 2011;28:1035‐1040)
- 19 August 2011
- Published by Wiley in Echocardiography
- Vol. 28 (9) , 1035-1040
Quadricuspid Aortic Valve: A Report of 12 Cases and a Review of the Literature
Quadricuspid aortic valve (QAV) is rare and its diagnosis, clinical course, and management are less well defined relative to other aortic valve abnormalities. Advances in diagnostic imaging, notably in ultrasound, have increased clinical awareness of this anomaly and prompted this review of our experience with 12 new patients and a compilation of previously reported patients to further characterize this condition. (Echocardiography 2011;28:1035‐1040)
- 1 July 2009
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 25 (7) , 429-431
An unusual case of infective endocarditis: Extension of a tricuspid valve vegetation into the left atrium through a patent foramen ovale
- 1 July 2009
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 25 (7) , 429-431
An unusual case of infective endocarditis: Extension of a tricuspid valve vegetation into the left atrium through a patent foramen ovale
- 8 March 2009
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (4) , 572-575
Three-dimensional echocardiography-guided repair of severe paravalvular regurgitation in a bioprosthetic and mechanical mitral valve
Severe paravalvular mitral regurgitation is a rare but important complication of mitral valve replacement, often producing symptoms associated with refractory heart failure or haemolysis. Explantation and replacement of the prosthesis are required in some patients but may not be possible in patients with high risk of morbidity or mortality with re-operation. We present two patients with symptomatic paravalvular mitral regurgitation who were deemed too high risk for re-operation because of multiple previous sternotomies and comorbidities. Percutaneous three-dimensional (3D) echocardiography-guided repair with septal occluder devices was undertaken in the first case of a paravalvular defect adjacent to a mitral bioprosthesis and in the second case adjacent to a mechanical mitral prosthesis. Both cases illustrate the advantage 3D echocardiography provides by allowing en-face views of the paravalvular leak and unique views of the catheter and device placement. The second case further demonstrates the novel use of full volume colour to define the extent of the regurgitant jet and provides information critical to device sizing and placement.
- 8 March 2009
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (4) , 572-575
Three-dimensional echocardiography-guided repair of severe paravalvular regurgitation in a bioprosthetic and mechanical mitral valve
Severe paravalvular mitral regurgitation is a rare but important complication of mitral valve replacement, often producing symptoms associated with refractory heart failure or haemolysis. Explantation and replacement of the prosthesis are required in some patients but may not be possible in patients with high risk of morbidity or mortality with re-operation. We present two patients with symptomatic paravalvular mitral regurgitation who were deemed too high risk for re-operation because of multiple previous sternotomies and comorbidities. Percutaneous three-dimensional (3D) echocardiography-guided repair with septal occluder devices was undertaken in the first case of a paravalvular defect adjacent to a mitral bioprosthesis and in the second case adjacent to a mechanical mitral prosthesis. Both cases illustrate the advantage 3D echocardiography provides by allowing en-face views of the paravalvular leak and unique views of the catheter and device placement. The second case further demonstrates the novel use of full volume colour to define the extent of the regurgitant jet and provides information critical to device sizing and placement.