SAStéphane Aubert

Stéphane Aubert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stéphane Aubert has a total of 58 co-authors. Here are the top co-authors by number of shared publications:

  • Iradj Gandjbakhch

    7 shared publications
  • Erwan Flecher

    5 shared publications
  • Alain Pavie

    Thoracic and Cardiovascular Surgery Department, Pierre and Marie Curie University (Paris VI) Pitié‐Salpêtrière Hospital, Assistance Publique‐Hôpitaux de Paris, Paris, France

    4 shared publications
  • Nicola Vistarini

    Department of Thoracic and Cardiovascular Surgery, Pierre et Marie Curie University, Pitié Salpêtrière Hospital, Institut du Coeur, Paris, France

    4 shared publications
  • Pascal Leprince

    Thoracic and Cardiovascular Surgery Department, Pierre and Marie Curie University (Paris VI) Pitié‐Salpêtrière Hospital, Assistance Publique‐Hôpitaux de Paris, Paris, France

    4 shared publications
  • Christophe Acar

    Department of Cardiovascular Surgery, Hopital de la Salpetriere, 75013 Paris, France

    3 shared publications

Latest Publications

  • Open Access

    Low tidal volume mechanical ventilation against no ventilation during cardiopulmonary bypass heart surgery (MECANO): study protocol for a randomized controlled trial

    by Lee S. Nguyen, Messaouda Merzoug, Philippe Estagnasie, Alain Brusset, Jean-Dominique Law Koune, Stephane Aubert, Thierry Waldmann, Jean-Michel Grinda, Hadrien Gibert, Pierre Squara

    Postoperative pulmonary complications are a leading cause of morbidity and mortality after cardiac surgery. There are no recommendations on mechanical ventilation associated with cardiopulmonary bypass (CPB) during surgery and anesthesiologists perform either no ventilation (noV) at all during CPB or maintain low tidal volume (LTV) ventilation. Indirect evidence points towards better pulmonary outcomes when LTV is performed but no large-scale prospective trial has yet been published in cardiac surgery. The MECANO trial is a single-center, double-blind, randomized, controlled trial comparing two mechanical ventilation strategies, noV and LTV, during cardiac surgery with CPB. In total, 1500 patients are expected to be included, without any restrictions. They will be randomized between noV and LTV on a 1:1 ratio. The noV group will receive no ventilation during CPB. The LTV group will receive 5 breaths/minute with a tidal volume of 3 mL/kg and positive end-expiratory pressure of 5 cmH2O. The primary endpoint will be a composite of all-cause mortality, early respiratory failure defined as a ratio of partial pressure of oxygen/fraction of inspired oxygen <200 mmHg at 1 hour after arrival in the ICU, heavy oxygenation support (defined as a patient requiring either non-invasive ventilation, mechanical ventilation or high-flow oxygen) at 2 days after arrival in the ICU or ventilator-acquired pneumonia defined by the Center of Disease Control. Lung recruitment maneuvers will be performed in the noV and LTV groups at the end of surgery and at arrival in ICU with an insufflation at +30 cmH20 for 5 seconds. Secondary endpoints are those composing the primary endpoint with the addition of pneumothorax, CPB duration, quantity of postoperative bleeding, red blood cell transfusions, revision surgery requirements, length of stay in the ICU and in the hospital and total hospitalization costs. Patients will be followed until hospital discharge. The MECANO trial is the first of its kind to compare in a double-blind design, a no-ventilation to a low-tidal volume strategy for mechanical ventilation during cardiac surgery with CPB, with a primary composite outcome including death, respiratory failure and postoperative pneumonia. ClinicalTrials.gov, NCT03098524 . Registered on 27 February 2017.


    • 1 January 2011
      • Vol. 20  (1) , 70-4

    First experimental use of magnets in cardiac valve repair.

    by Mojgan Laali, Erwan Flécher, Bertrand Nogarede, Nicolas Martinez, Stéphane Aubert, Pascal Leprince, Iradj Gandjbakhch

    Valve repair is currently performed to treat mitral regurgitation, but aortic valve repair remains a surgical challenge. In contrast, aortic valve replacement leads to complications and constraints on the patients' quality of life and valve durability. The mechanisms that produce malcoaptation of the aortic leaflets, with resultant insufficiency, are mainly due to prolapse or retraction of the leaflets. Thus, a new strategy has been proposed to correct valvular insufficiency, using magnetic force. Low-profile permanent magnets were implanted in seven sheep, under cardiopulmonary bypass (CPB), through a transverse aortotomy, and maintained in place for three months. No aortic insufficiency was created in these first experiments. Two-dimensional color Doppler echocardiography was used to assess the function and safeguarding of the aortic valve. Blood samples were withdrawn to assess hemolysis, and histopathologic examinations performed at necropsy. Direct implantation of the three permanent magnets was possible in all seven animals, but the surgical procedure resulted in major complications in three cases. Only five animals could be weaned from CPB, and only four survived the procedure at three months. One magnet was also shown to have migrated postoperatively. Echocardiography confirmed the stability of the aortic leaflet contours. The biocompatibility of the implanted magnets (i.e., absence of hemolytic reaction) was found to be satisfactory, without a need for postoperative anticoagulation. The use of magnetic force to correct valvular insufficiency has not previously been reported, and is an interesting field of investigation. Whilst these experiments are at an early stage of development, future changes in magnet design and surgical approach are indicated.

  • Open Access

    A simplified surgical approach for aortic valve replacement after previous coronary artery bypass grafting

    by Nicola Vistarini, Stéphane Aubert, Pascal Leprince, Alain Pavie

    Aortic valve replacement (AVR) in patients who have undergone previous coronary artery bypass grafting (CABG) is a challenging redo surgery. We undertook this study to evaluate the early and late outcomes of patients operated upon using a simplified surgical approach. Between January 2001 and December 2005, 2238 patients underwent AVR in our institution. We reviewed retrospectively the 57 patients who had AVR following previous CABG. All patients underwent cardiopulmonary bypass with a mild-to-moderate systemic hypothermia (mean temperature: 29.7 ± 2.5 °C). Patent internal thoracic artery (IMA) grafts were never dissected, controlled or clamped. A mechanical or biological prosthesis was implanted considering the patient’s age. The mean cardiopulmonary bypass (CPB) time was 93 ± 29 min (median: 80 min, range: 43–244 min) and the mean aortic cross-clamp (AoX) time was 63 ± 18 min (median: 59 min, range: 31–125 min). The early mortality was 10.5% and the late mortality was 9.8% (mean follow-up time: 38 months). The survival was 81% at 5 years and the freedom from major cardiac events was 77%. In conclusion, from our experience, the operating quickness and a simplified approach (‘open IMA technique’, anterograde cardioplegia, mild-to-moderate hypothermia and minimal dissection of the mediastinal structures) represent two fundamental choices to perform this type of surgery easily, safely and with optimal results.


    • 1 May 2009
      • Vol. 18  (3) , 290-1

    Gaping cleft or commissure--an under-rated cause of residual mitral insufficiency following valve repair: case reports.

    by Stéphane Aubert, Christophe Acar

    Naturally occurring clefts in the posterior leaflet of the mitral valve and/or the mitral commissures themselves may become the foci of residual mitral regurgitation when distorted by an adjacent rigid suture line. Herein are reported the details of three cases in which cleft/commissure closure resolved such leaks. The anatomical substrate which predisposed to this problem is also discussed.

  • Acute pulmonary valve endocarditis

    by Stephane Aubert, Beltran Levy Praschker, Iradj Gandjbakhch


  • Open Access

    Aberrant subclavian artery as origin of aortic dissection

    by Nicola Vistarini, Stéphane Aubert, Iradj Gandjbakhch, Nicolas Bonnet

    A 65-year-old woman presented with a severe pain between shoulder blades. CT scan revealed a type A aortic dissection with the intimal flap originating from the distal portion of the aortic arch, just at the origin of the aberrant right subclavian artery (Figs. 1 and 2 ).


  • A Safe Option to Perform an Apparent Difficult Redo Surgery

    by Nicola Vistarini, Stephane Aubert, Sylvain Rubin, Eleodoro Barreda, Alain Pavie, Pascal Leprince

    A 50-year-old female operated of Bentall five years before was referred to our hospital for an aneurysm of both right subclavian artery and brachiocephalic trunk associated with a false anastomotic aneurysm on the insertion of the left coronary artery. The procedure was performed under moderate hypothermic circulatory arrest; the false aneurysm was repaired, the brachiocephalic trunk and the subclavian aneurysm were resected, an aorto-carotid and axillary bypass were finally performed. The postoperative course was uneventful. She was discharged to home on postoperative day 7. At six-month follow-up, she was still asymptomatic.

  • Bullet Embolization from the Left Brachiocephalic Vein to the Right Ventricle

    by V. Bors, S. Aubert, E. Flecher, N. Bonnet, C. D'Alessandro, I. Gandjbakhch, A. Pavie

    We present a rare case of bullet embolism from the left brachiocephalic vein to the right ventricle, following a chest gunshot wound, in a 56-year-old soldier. The bullet was accidentally discovered on a systematic chest X-ray. The bullet was very close to the tricuspid subvalvular apparatus and was about to come out from the ventricle. We removed it under cardiopulmonary bypass.


    • 1 November 2007
      • Vol. 16  (6) , 611-6

    Surgery for infective endocarditis on mitral annulus calcification.

    by Nicola Vistarini, Cosimo D'alessandro, Stéphane Aubert, Frédérique Jault, Christophe Acar, Alain Pavie, Iradj Gandjbakhch

    The study aim was to assess the characteristics of bacterial endocarditis complicating mitral annulus calcification, and to evaluate the surgical results. Twenty-four patients (mean age 64 years) underwent surgery for mitral insufficiency secondary to mitral endocarditis with annulus calcification (acute, n = 18; healed, n = 6). Surgery was performed as an emergency in seven cases for septic (n = 3) or cardiogenic (n = 4) shock. An aortic prosthesis had previously been placed in three cases. Comorbidities noted included chronic renal insufficiency/dialysis (n = 8), cancer (n = 6), coronary disease (n = 6), and obstructive cardiomyopathy (n = 1). Nine patients suffered an embolic complication, such as stroke (n = 7, of which three had coma), splenic (n = 3), or lower limb (n = 1). The microorganism present was identified as Staphylococcus aureus (n = 9), Streptococcus/ Enterococcus sp. (n = 12), or others (n = 3). The left atrial diameter was 48 mm, the ejection fraction 63%, and the septal thickness 13 mm. The mean severity score of annulus calcifications (range: 1 to 5) was 1.9. The anatomical lesions included: vegetations (n = 16, of which eight were > 10 mm), leaflet perforation (n = 9), chordae rupture (n = 9), aortic abscess (n = 2) and mitral annular abscess (n = 9), and one fistulation into the pericardium. The valve was repaired in 15 cases, and replaced in nine (seven bioprostheses, two mechanical). Associated procedures included aortic valve replacement (n = 7) and coronary artery bypass (n = 3). The in-hospital mortality was 29% (n = 7); all patients who died were operated on during the acute phase. All patients who presented with septic shock or coma died. After a mean follow up of 46 months, six patients had died (overall survival was 46% at 33 months), and 11 were in NYHA class I/II. One recurrence of endocarditis was treated medically. Bacterial endocarditis complicating mitral annulus calcification has a poor prognosis due to the frequent comorbidity and severity of the infectious complications. Patients in septic shock or coma do not appear to be suitable candidates for surgery. Valve repair was possible in two-thirds of the present patients; otherwise, a bioprosthetic replacement was the option of choice.