Pascal Morel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pascal Morel has a total of 133 co-authors. Here are the top co-authors by number of shared publications:
- Xavier Bertrand
Université Marie et Louis Pasteur, CHU Besançon, CNRS, Chrono-environnement (UMR 6249), Laboratoire d’hygiène , F-25000 Besançon
5 shared publications C. Naegelen
3 shared publicationsL. Bardiaux
3 shared publicationsM. Deschaseaux
3 shared publicationsC Naegelen
2 shared publications- Cheuk Kwong Lee
Hong Kong Red Cross Blood Transfus Serv, Hong Kong, Peoples R China
2 shared publications
Latest Publications
- Open Access
Insights on 21 Years of HBV Surveillance in Blood Donors in France
Hepatitis B virus (HBV) infection is the most frequent viral infection found in blood donors (BDs) in France. We analyzed the epidemiological and sero-molecular data on HBV infection gathered over the past two decades by the French haemovigilance surveillance network, blood screening laboratories, and the national reference center for transfusion infectious risks (NRC). Between 2000 and 2020, 6149 of the 58,160,984 donations (1.06/10,000) tested HBV positive, 98% of them from first-time blood donors (FTBDs). In addition, 2212 (0.0071%) of the 30,977,753 donations screened for HBV DNA tested DNA positive, of which 25 (1.1%) were positive only for this marker. HBV prevalence decreased by 2.8-fold and the residual risk for transfusion-transmitted HBV infection decreased 13-fold and was divided by 13. The major risk factor for HBV infection was the origin of donors (endemic country, 66.5%), followed by parenteral exposure (10.7%). In the whole HBV-positive BD population, genotype D was predominant (41.8%), followed by genotypes A (26.2%) and E (20.4%), reflecting the geographical origin of donors. The low and decreasing prevalence and incidence of HBV infection in French BDs, coupled with a screening strategy using three HBV markers (HBsAg, anti-HBc and DNA), ensures a high level of blood safety, further reinforced by the implementation of pathogen-reduction measures.
Open AccessInsights on 21 Years of HBV Surveillance in Blood Donors in France
Hepatitis B virus (HBV) infection is the most frequent viral infection found in blood donors (BDs) in France. We analyzed the epidemiological and sero-molecular data on HBV infection gathered over the past two decades by the French haemovigilance surveillance network, blood screening laboratories, and the national reference center for transfusion infectious risks (NRC). Between 2000 and 2020, 6149 of the 58,160,984 donations (1.06/10,000) tested HBV positive, 98% of them from first-time blood donors (FTBDs). In addition, 2212 (0.0071%) of the 30,977,753 donations screened for HBV DNA tested DNA positive, of which 25 (1.1%) were positive only for this marker. HBV prevalence decreased by 2.8-fold and the residual risk for transfusion-transmitted HBV infection decreased 13-fold and was divided by 13. The major risk factor for HBV infection was the origin of donors (endemic country, 66.5%), followed by parenteral exposure (10.7%). In the whole HBV-positive BD population, genotype D was predominant (41.8%), followed by genotypes A (26.2%) and E (20.4%), reflecting the geographical origin of donors. The low and decreasing prevalence and incidence of HBV infection in French BDs, coupled with a screening strategy using three HBV markers (HBsAg, anti-HBc and DNA), ensures a high level of blood safety, further reinforced by the implementation of pathogen-reduction measures.
- 8 November 2022
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 29 (4) , 331
L-65 L’EFS en situation de crise sanitaire et risque : retour d’expérience
- 8 November 2022
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 29 (4) , 331
L-65 L’EFS en situation de crise sanitaire et risque : retour d’expérience
- 20 May 2021
- Published by Wiley in Vox Sanguinis
- Vol. 116 (10) , E71-E120
International Forum on the Collection and Use of COVID‐19 Convalescent Plasma: Responses
- 20 May 2021
- Published by Wiley in Vox Sanguinis
- Vol. 116 (10) , E71-E120
International Forum on the Collection and Use of COVID‐19 Convalescent Plasma: Responses
- Open Access
- 22 March 2021
- Published by Wiley in Vox Sanguinis
- Vol. 116 (3) , e1-e24
International Forum on Mitigation Strategies to Prevent Faint and Pre‐faint Adverse Reactions in Whole Blood Donors: Responses
- 22 March 2021
- Published by Wiley in Vox Sanguinis
- Vol. 116 (3) , e1-e24
Open AccessInternational Forum on Mitigation Strategies to Prevent Faint and Pre‐faint Adverse Reactions in Whole Blood Donors: Responses
- 1 May 2013
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 20 (2) , 109-114
Prévention du risque bactérien : inactivation des pathogènes/détection des bactéries
- 1 May 2013
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 20 (2) , 109-114
Prévention du risque bactérien : inactivation des pathogènes/détection des bactéries
- 1 May 2013
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 20 (2) , 174-181
Maîtrise du risque bactérien transfusionnel en France en 2013
- 1 May 2013
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 20 (2) , 174-181
Maîtrise du risque bactérien transfusionnel en France en 2013
- 1 April 2011
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 18 (2) , 133-139
Dix ans de diagnostic génomique viral : leçons et perspectives
- 1 April 2011
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 18 (2) , 133-139
Dix ans de diagnostic génomique viral : leçons et perspectives
- 2 December 2005
- Published by Wiley in Transfusion
- Vol. 46 (2) , 220-224
Evaluation of the enhanced bacterial detection system for screening of contaminated platelets
BACKGROUND: The Pall third‐generation enhanced bacterial detection system (eBDS) was recently approved for detection of bacterial contamination in leukoreduced platelets (PLTs). The method is based on the measurement of the oxygen content as a marker for bacteria. eBDS incorporates major modifications including removal of the sample‐set filter, modification of the culture medium, and incubation with agitation of the sample pouch.STUDY DESIGN AND METHODS: Ten whole blood–derived random‐donor PLT units collected on Day 1 after donation and 10 single‐donor apheresis PLT units were spiked with low levels of bacteria in three different blood transfusion centers. Inoculation was performed at a final concentration of 5 to 50 colony‐forming units per mL with reference strains of five organisms involved in severe transfusion‐associated infections. PLT units were stored at 22°C for 24 hours before sampling. Six sample sets were then sterile‐connected to each unit and placed on a horizontal agitator at 35°C for 18 or 24 hours of incubation.RESULTS: No false‐positive results were obtained, indicating a 100 percent specificity of the assay. Of 126 spiked sample pouches tested, 61 of 63 (96.82%) and 63 of 63 (100%) were detected positive after 18 or 24 hours of incubation, respectively. In the two missed cases that failed to detect Bacillus cereus, the measured oxygen was slightly above the detection threshold but was markedly different from the negative samples.CONCLUSION: The eBDS method allows definitive testing of PLTs as soon as 42 hours after collection and offers an alternative culture method to the BacT/ALERT system.
- 2 December 2005
- Published by Wiley in Transfusion
- Vol. 46 (2) , 220-224
Evaluation of the enhanced bacterial detection system for screening of contaminated platelets
BACKGROUND: The Pall third‐generation enhanced bacterial detection system (eBDS) was recently approved for detection of bacterial contamination in leukoreduced platelets (PLTs). The method is based on the measurement of the oxygen content as a marker for bacteria. eBDS incorporates major modifications including removal of the sample‐set filter, modification of the culture medium, and incubation with agitation of the sample pouch.STUDY DESIGN AND METHODS: Ten whole blood–derived random‐donor PLT units collected on Day 1 after donation and 10 single‐donor apheresis PLT units were spiked with low levels of bacteria in three different blood transfusion centers. Inoculation was performed at a final concentration of 5 to 50 colony‐forming units per mL with reference strains of five organisms involved in severe transfusion‐associated infections. PLT units were stored at 22°C for 24 hours before sampling. Six sample sets were then sterile‐connected to each unit and placed on a horizontal agitator at 35°C for 18 or 24 hours of incubation.RESULTS: No false‐positive results were obtained, indicating a 100 percent specificity of the assay. Of 126 spiked sample pouches tested, 61 of 63 (96.82%) and 63 of 63 (100%) were detected positive after 18 or 24 hours of incubation, respectively. In the two missed cases that failed to detect Bacillus cereus, the measured oxygen was slightly above the detection threshold but was markedly different from the negative samples.CONCLUSION: The eBDS method allows definitive testing of PLTs as soon as 42 hours after collection and offers an alternative culture method to the BacT/ALERT system.
- 1 June 2005
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 12 (2) , 215-220
Vers la détection des bactéries dans les PSL
- 1 June 2005
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 12 (2) , 215-220
Vers la détection des bactéries dans les PSL
- 1 June 2005
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 12 (2) , 142-149
De la détection bactérienne à l'inactivation des pathogènes
- 1 June 2005
- Published by Elsevier in Transfusion Clinique et Biologique
- Vol. 12 (2) , 142-149
De la détection bactérienne à l'inactivation des pathogènes