Claude Fermon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Claude Fermon has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Myriam Pannetier Lecoeur
SPEC, CEA, CNRS, Université Paris-Saclay
4 shared publications - Paulo Peixeiro Freitas
Instituto de Engenharia de Sistemas e Computadores—Microsistemas e Nanotecnologias (INESC MN)
2 shared publications - Anne Wijkhuisen
Service de Pharmacologie et Immunoanalyse (SPI), Laboratoire d’Etudes et de Recherches en Immunoanalyse, CEA, INRA, Université Paris-Saclay, 91191 Gif-sur-Yvette, France
1 shared publication - Aurelie Solignac
SPEC and LIST (CEA Saclay, CNRS, Université Paris-Saclay) France
1 shared publication - Belen Ribes
Tecnatom, Spain
1 shared publication Christopher Murphy Lewis
Ernst Strüngmann Institute (ESI) for Neuroscience in Cooperation with Max Planck Society
1 shared publication
Latest Publications
- Open Access
- 31 August 2019
- Published by MDPI AG in Biosensors
- Vol. 9 (3) , 105
Evaluation of In-Flow Magnetoresistive Chip Cell—Counter as a Diagnostic Tool
Inexpensive simple medical devices allowing fast and reliable counting of whole cells are of interest for diagnosis and treatment monitoring. Magnetic-based labs on a chip are one of the possibilities currently studied to address this issue. Giant magnetoresistance (GMR) sensors offer both great sensitivity and device integrability with microfluidics and electronics. When used on a dynamic system, GMR-based biochips are able to detect magnetically labeled individual cells. In this article, a rigorous evaluation of the main characteristics of this magnetic medical device (specificity, sensitivity, time of use and variability) are presented and compared to those of both an ELISA test and a conventional flow cytometer, using an eukaryotic malignant cell line model in physiological conditions (NS1 murine cells in phosphate buffer saline). We describe a proof of specificity of a GMR sensor detection of magnetically labeled cells. The limit of detection of the actual system was shown to be similar to the ELISA one and 10 times higher than the cytometer one.
- 31 August 2019
- Published by MDPI AG in Biosensors
- Vol. 9 (3) , 105
Open AccessEvaluation of In-Flow Magnetoresistive Chip Cell—Counter as a Diagnostic Tool
Inexpensive simple medical devices allowing fast and reliable counting of whole cells are of interest for diagnosis and treatment monitoring. Magnetic-based labs on a chip are one of the possibilities currently studied to address this issue. Giant magnetoresistance (GMR) sensors offer both great sensitivity and device integrability with microfluidics and electronics. When used on a dynamic system, GMR-based biochips are able to detect magnetically labeled individual cells. In this article, a rigorous evaluation of the main characteristics of this magnetic medical device (specificity, sensitivity, time of use and variability) are presented and compared to those of both an ELISA test and a conventional flow cytometer, using an eukaryotic malignant cell line model in physiological conditions (NS1 murine cells in phosphate buffer saline). We describe a proof of specificity of a GMR sensor detection of magnetically labeled cells. The limit of detection of the actual system was shown to be similar to the ELISA one and 10 times higher than the cytometer one.
- 5 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (22) , 10403-10408
3D Magnetic Imaging With GMR Sensors
This paper reports on the development of spin electronics based probes for 3D magnetic imaging. We have demonstrated the feasibility of using four orientations of magnetoresistive sensors (GMR) for the reconstruction of three dimensional components of magnetic field at the same measurement point. The use of different GMR sensor structures makes it possible to adapt the sensitivity and field range to the signal to detect for a specific application. Their characteristics and field reconstruction steps are also shown. Different examples of magnetic imaging are presented.
- 5 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (22) , 10403-10408
3D Magnetic Imaging With GMR Sensors
This paper reports on the development of spin electronics based probes for 3D magnetic imaging. We have demonstrated the feasibility of using four orientations of magnetoresistive sensors (GMR) for the reconstruction of three dimensional components of magnetic field at the same measurement point. The use of different GMR sensor structures makes it possible to adapt the sensitivity and field range to the signal to detect for a specific application. Their characteristics and field reconstruction steps are also shown. Different examples of magnetic imaging are presented.
- 7 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (9) , 7326-7337
High-Resolution Nondestructive Test Probes Based on Magnetoresistive Sensors
This work discloses two high-sensitivity probes for Eddy Current Non-Destructive Test (NDT) of buried and surface defects. These probes incorporate 8 and 32 magnetoresistive sensors, respectively, which are optimized for high sensitivity and spatial resolution. The signal processing and interfacing are carried out by a full-custom Application Specific Integrated Circuit (ASIC). The ASIC signal chain performs with a thermal input-referred noise of 30 nV/ $\sqrt{\mathrm {HZ}}$ at 1 kHz, with 66 mW of power consumption, in a die with 3.7×3.4 mm $^2$ . NDT results are presented, showing that there is an increase in spatial resolution of surface defects when contrasted to prior art, enabling the probes to resolve defects with diameters of 0.44 mm, pitches of 0.6 mm, and minimum edge distance as low as 0.16 mm. The results also show that the probe for buried defects is a good all-round tool for detection of defects under cladding and multiple-plate flat junctions.- 7 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (9) , 7326-7337
High-Resolution Nondestructive Test Probes Based on Magnetoresistive Sensors
This work discloses two high-sensitivity probes for Eddy Current Non-Destructive Test (NDT) of buried and surface defects. These probes incorporate 8 and 32 magnetoresistive sensors, respectively, which are optimized for high sensitivity and spatial resolution. The signal processing and interfacing are carried out by a full-custom Application Specific Integrated Circuit (ASIC). The ASIC signal chain performs with a thermal input-referred noise of 30 nV/ $\sqrt{\mathrm {HZ}}$ at 1 kHz, with 66 mW of power consumption, in a die with 3.7×3.4 mm $^2$ . NDT results are presented, showing that there is an increase in spatial resolution of surface defects when contrasted to prior art, enabling the probes to resolve defects with diameters of 0.44 mm, pitches of 0.6 mm, and minimum edge distance as low as 0.16 mm. The results also show that the probe for buried defects is a good all-round tool for detection of defects under cladding and multiple-plate flat junctions.- Open Access
In vivo magnetic recording of neuronal activity
SUMMARY: Neuronal activity generates ionic flows and thereby both magnetic fields and electric potential differences, i.e. voltages. Voltage measurements are widely used, but suffer from isolating and smearing properties of tissue between source and sensor, are blind to ionic flow direction, and reflect the difference between two electrodes, complicating interpretation. Magnetic field measurements could overcome these limitations, but have been essentially limited to magnetoencephalography (MEG), using centimeter-sized, helium-cooled extracranial sensors. Here, we report on in vivo magnetic recordings of neuronal activity from visual cortex of cats with magnetrodes , specially developed needle-shaped probes carrying micron-sized, non-cooled magnetic sensors based on spin electronics. Event-related magnetic fields inside the neuropil were on the order of several nanoteslas, informing MEG source models and efforts for magnetic field measurements through MRI. Though the signal-to-noise ratio is still inferior to electrophysiology, this proof of concept demonstrates the potential to exploit the fundamental advantages of magnetophysiology. HIGHLIGHTS: Spin-electronics based probes achieve local magnetic recordings inside the neuropil Magnetic field recordings were performed in vivo, in anesthetized cat visual cortex Event-related fields (ERFs) to visual stimuli were up to several nanoteslas in size ERFs could be detected after averaging less than 20 trials IN BRIEF: Caruso et al. report in vivo, intra-cortical recordings of magnetic fields that reflect neuronal activity, using magnetrodes, i.e. micron size magnetic sensors based on spin electronics.
Open AccessIn vivo magnetic recording of neuronal activity
SUMMARY: Neuronal activity generates ionic flows and thereby both magnetic fields and electric potential differences, i.e. voltages. Voltage measurements are widely used, but suffer from isolating and smearing properties of tissue between source and sensor, are blind to ionic flow direction, and reflect the difference between two electrodes, complicating interpretation. Magnetic field measurements could overcome these limitations, but have been essentially limited to magnetoencephalography (MEG), using centimeter-sized, helium-cooled extracranial sensors. Here, we report on in vivo magnetic recordings of neuronal activity from visual cortex of cats with magnetrodes , specially developed needle-shaped probes carrying micron-sized, non-cooled magnetic sensors based on spin electronics. Event-related magnetic fields inside the neuropil were on the order of several nanoteslas, informing MEG source models and efforts for magnetic field measurements through MRI. Though the signal-to-noise ratio is still inferior to electrophysiology, this proof of concept demonstrates the potential to exploit the fundamental advantages of magnetophysiology. HIGHLIGHTS: Spin-electronics based probes achieve local magnetic recordings inside the neuropil Magnetic field recordings were performed in vivo, in anesthetized cat visual cortex Event-related fields (ERFs) to visual stimuli were up to several nanoteslas in size ERFs could be detected after averaging less than 20 trials IN BRIEF: Caruso et al. report in vivo, intra-cortical recordings of magnetic fields that reflect neuronal activity, using magnetrodes, i.e. micron size magnetic sensors based on spin electronics.
- 8 October 2015
- Published by Springer Nature
- p. 103-109
Applications II: The Secret Revolution of Magnetic Sensors
- 8 October 2015
- Published by Springer Nature
- p. 103-109
Applications II: The Secret Revolution of Magnetic Sensors
- 6 July 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 303 (1) , 012008
Spin wave propagation in ferromagnetic wires with an arbitrary field direction
We report on the measurements of quantized spin waves spectra in thin ferromagnetic wires with an arbitrary field orientation obtained by using an original micro antenna configuration. The high efficiency of energy transfer from the micro antenna to the magnetic wires allows us fabricating devices using remanent magnetization configuration
- 6 July 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 303 (1) , 012008
Spin wave propagation in ferromagnetic wires with an arbitrary field direction
We report on the measurements of quantized spin waves spectra in thin ferromagnetic wires with an arbitrary field orientation obtained by using an original micro antenna configuration. The high efficiency of energy transfer from the micro antenna to the magnetic wires allows us fabricating devices using remanent magnetization configuration
- Open Access
- 26 March 2010
- Published by EDP Sciences in Reflets de la physique
- No. 18,p. 8-11
Électronique despinet capteurs magnétiques
Les capteurs de champ magnétique ont de nombreuses applications : lecture de disques durs, contrôle de positionnement dans l'espace, codage de position et d'angle, mesure de courant électrique sans contact, imagerie magnétique, contrôle non destructif, imagerie médicale… Parmi les différents types de capteurs magnétiques, ceux issus de l'électronique de spin offrent la possibilité d'une grande sensibilité sur une petite échelle spatiale. Utilisés systématiquement dans le domaine des têtes de lecture des disques durs (voir l'article de J.P. Nozières, p. 12), leur production en grande série pour d'autres applications vient de commencer.
- 26 March 2010
- Published by EDP Sciences in Reflets de la physique
- No. 18,p. 8-11
Open AccessÉlectronique despinet capteurs magnétiques
Les capteurs de champ magnétique ont de nombreuses applications : lecture de disques durs, contrôle de positionnement dans l'espace, codage de position et d'angle, mesure de courant électrique sans contact, imagerie magnétique, contrôle non destructif, imagerie médicale… Parmi les différents types de capteurs magnétiques, ceux issus de l'électronique de spin offrent la possibilité d'une grande sensibilité sur une petite échelle spatiale. Utilisés systématiquement dans le domaine des têtes de lecture des disques durs (voir l'article de J.P. Nozières, p. 12), leur production en grande série pour d'autres applications vient de commencer.
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 70-73
Magnetoresistive Hybrid Sensors for Simultaneous Low-Field MRI and Biomagnetic Measurements
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 70-73
Magnetoresistive Hybrid Sensors for Simultaneous Low-Field MRI and Biomagnetic Measurements