SHStein Holme

Stein Holme

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stein Holme has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Andrew Heaton

    From the American Red Cross, Mid‐Atlantic Region, Norfolk, Virginia

    1 shared publication
  • Carl P. McDonald

    From Pall Medical, Covina, California; Case Western Reserve University and University Hospitals Case Medical Center, Cleveland, Ohio; and the National Blood Service, Colindale, London, UK

    1 shared publication
  • Constance Pickard

    From the American Red Cross, Holland Laboratory, Rockville, Maryland; the Dartmouth‐Hitchcock Medical Center, Lebanon, New Hampshire; the American Red Cross, Mid‐Atlantic Region, Norfolk, Virginia

    1 shared publication
  • Cyndi L. Chen

    Pall Medical, Covina, California 91722, USA

    1 shared publication
  • Deanna McNeil

    From the American Red Cross, Mid‐Atlantic Region, Norfolk, Virginia

    1 shared publication
  • Gary Moroff

    American Red Cross, Holland Laboratory, Rockville, MD 20855, USA

    1 shared publication

Latest Publications

  • Evaluation of the properties of components prepared and stored after holding of whole blood units for 8 and 24 hours at ambient temperature

    by Gary Moroff, James P. AuBuchon, Constance Pickard, Pamela H. Whitley, W. Andrew Heaton, Stein Holme

    The capability of holding whole blood (WB) units at ambient temperature, overnight, should help in platelet (PLT) concentrate preparation logistics. We summarize the results of a study conducted in the early 1990s that compared, in particular, PLT and red blood cell (RBC) in vivo viability properties following storage after preparation after 8- and 24-hour WB hold periods. Individuals donated units of WB on two occasions. Centrifugation at 20 to 24°C to separate PLTs and additive system RBC placement at 1 to 6°C was completed 8 hours after phlebotomy or after 24 hours in randomized order. Components were not leukoreduced. Studies including in vitro biochemical and hematologic analyses and autologous in vivo RBC and PLT evaluations were conducted at two sites. RBC 24-hour in vivo (mean ± SD) recoveries (single-label approach), after 35 days of storage, were 79.2 ± 4.3 and 79.4 ± 3.9% (n = 9; p > 0.05), with WB holding periods of 8 and 24 hours, respectively. With 42 days of storage, recovery after a 24-hour hold was slightly less than with an 8-hour hold (72.9 ± 6.5% vs. 76.0 ± 5.4%; n = 17; p < 0.05). RBC 2,3-diphosphoglycerate acid levels were substantially less after the 24-hour hold compared to after the 8-hour hold (n = 18; p < 0.05). PLT recovery after 5 days of storage with 8- and 24-hour hold periods were similar, 51.1 ± 14.9 and 50.6 ± 17.7%, respectively (n = 18; p > 0.05). The PLT survival variable and in vitro properties reflecting storage quality also showed no significant difference. RBC and PLT in vivo variables, and most in vitro variables, were not significantly different after storage with WB holding times of 8 and 24 hours except for a slight diminution of RBC recovery with the 24-hour hold after 42 days of storage.


  • Detection of bacteria in stored red cell products using a culture‐based bacterial detection system

    by Cyndi L. Chen, Jing‐Chen Yu, Stein Holme, Michael R. Jacobs, Roslyn Yomtovian, Carl P. McDonald

    BACKGROUND: The Pall eBDS uses oxygen consumption as a surrogate marker for bacterial detection in platelet (PLT) products. This article describes the evaluation of eBDS to detect bacterial contamination in inoculated fresh and stored leukoreduced red cell (RBC) units.STUDY DESIGN AND METHODS: Field studies were conducted at three sites to establish eBDS pouch incubation time and the pass/fail threshold. RBC units were inoculated with each of 12 bacterial species known to cause sepsis at target inocula of either 1 to 15 or 100 colony‐forming units (CFUs) per mL. Units were mixed and stored at 2 to 6°C. Samples were taken for culture and eBDS testing weekly from 0 hour to 42 days and incubated for 35°C for 24 to 30, 48, and 72 hours, followed by measurement of percent oxygen content.RESULTS: The studies showed growth of five bacterial species (including Yersinia enterocolitica) in RBC units, while seven bacterial species showed no growth or autosterilized. A pass/fail oxygen threshold of 14.4 percent was determined based on results from noninoculated controls (n = 633) and from inoculated samples (n = 884) after 48 hours of incubation. Detection was 100 percent at all sampling times during refrigerated storage with both 48 and 72 hours of pouch incubation.CONCLUSION: With incubation of eBDS pouches for 48 and 72 hours, 100 percent detection was obtained in 884 samples with bacterial levels of at least 1 CFU per mL, and no false‐positive samples were obtained. Based on the bacterial growth patterns, RBC units may be sampled 1 to 3 days after collection for optimal efficacy and read after 48 to 72 hours of incubation of the eBDS sample pouches at 35°C. The Pall eBDS is suited for detection of typical bacterial contaminants in fresh and stored RBCs.


  • Prediction of red cell and blood volumes distribution by various nomograms: do current nomograms overestimate?

    by Stein Holme, M. Dean Elfath, Andrew Heaton, Pamela Whitley, Deanna McNeil

    Currently used formulas for estimation of a person's red cell volume (RCV) by weight and height are decades old and were based on the use of 51Cr isotopes and on a sample population, which may not be reflective of today's population. In this study, the accuracy and precision of the use of 99mTc RCV measurements in volunteers more typical of today's population were evaluated.The subjects were volunteers who met the requirements for a standard blood donation.The mean +/- standard deviation (SD) 99mTc RCV for 127 males (mean weight, 83.2 kg; height, 180 cm) was 2062 +/- 339 mL, and for 101 females (mean weight, 69.5 kg; height, 166 cm) it was 1320 +/- 201 mL. These results were highly correlated with RCV results with the standard extrapolation 51Cr method with stored red blood cells (RBCs) and highly consistent (within +/-10%) by repeated measurements with the same 22 donors over a 3.5-year period. The RCV results correlated with estimates from the current formulas, but were on average 11 to 14 percent lower.The studies demonstrated that 99mTc is a reproducible and precise method for determination of a person's RCV and that current formulas may significantly overestimate the RCV of today's population. This is likely the result of a shift in population characteristics over the past four decades as reflected by an increased mean body mass index (from 25 to 28 kg/m2), which has not resulted in a proportionally increased RCV.


  • In vitro pH effects on in vivo recovery and survival of platelets: an analysis by the BEST Collaborative

    by Larry J. Dumont, James P. AuBuchon, Hans Gulliksson, Sherrill J. Slichter, M. Dean Elfath, Stein Holme, James R. Murphy, Leslie E. Rose, Mark A. Popovsky, Scott Murphy

    The pH environment of stored platelet (PLT) products is recognized as an important factor and is generally used as a key surrogate measure of PLT viability. It is the only in vitro measurement that has been translated into industry standards and regulatory rules or specifications for storage of PLT products. The objective of this study was to evaluate the effect of in vitro pH on the in vivo recovery and survival of autologous PLT products. Data from individual autologous radiolabeled PLT kinetic studies were solicited from independent laboratories. PLTs stored for at least 5 days in 100 percent autologous plasma with a pH(22 degrees C) of at least 6.2 were analyzed. Data were fit to a mixed-effects regression model with fixed effects of pH(22 degrees C), time of storage, and preparation method-storage bag combination. Eight research laboratories reported 476 individual recovery and survival results with associated pH before labeling from a variety of autologous, radiolabeled PLT kinetic studies from September 1999 to March 2005. These results are from 254 individual subjects who donated a total of 386 PLT units, with up to nine collections per subject reported. The effect of pH on either PLT recovery (p = 0.86) or survival (p = 0.55) was not significant. Time of storage and the method-bag combination both had significant effects on these outcomes (p < 0.0001). These data suggest that there is no relationship between in vitro pH at a pH(22 degrees C) of at least 6.2 and in vivo PLT viability as measured by radiolabeled recovery and survival of autologous PLTs.