Stephan Schmolke
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stephan Schmolke has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Christian Flamme
Orthopedics Department, Hannover Medical School, Hannover, Germany
3 shared publicationsF Pude
2 shared publicationsF. Gossé
2 shared publicationsL Kirsch
2 shared publicationsLudger Kirsch
2 shared publications- Michael Bohnsack
Orthopädische Klinik der Medizinischen Hochschule Hannover
2 shared publications
Latest Publications
- 1 May 2007
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und Unfallchirurgie
- Vol. 145 (03) , 343-347
Stellenwert von 3D-Ultraschall in der Orthopädie
3D-Ultraschall gewinnt in vielen medizinischen Disziplinen, z. B. in der Angiologie und pränatalen Diagnostik, an zunehmender Bedeutung. Studienziel: Ziel dieser Studie war der Vergleich der Aussagefähigkeit am Bewegungsapparat zwischen konventionellen 2D-Verfahren und einem 3D-Verfahren mit vollautomatisierter Datenerfassung. Methode: Über einen definierten Zeitraum wurden alle sonografischen Untersuchungen am Stütz- und Bewegungsapparat mit einem 3D-fähigen Ultraschallgerät durchgeführt. Alle Datensätze wurden manuell im Sinne eines aufwendigen und zeitintensiven „Postprocessing“ nachgearbeitet, da aufgrund der geringen Impedanzunterschiede eine automatisierte Gewebedifferenzierung nicht möglich war. Ergebnisse: Der wesentliche Vorteil der 3D-basierten Datenakquisition war, dass alle erfassten DEGUM-Standardebenen aus dem Scanvolumen abgeleitet werden können und damit das Umsetzen des Schallkopfes zur Einstellung einer zweiten Ebene entfällt. Die selektive Darstellung relevanter Strukturen, z. B. einer Rotatorenmanschette, war nur nach manueller Nachbearbeitung möglich. Schlussfolgerung: Zum jetzigen Zeitpunkt sind die Vorteile der 3D-Darstellung in der Diagnostik des Bewegungsapparates zu gering, als dass ihre Einführung in die tägliche Routine gerechtfertigt ist. 3D-ultrasonic is gaining more and more significance in many medical disciplines, e. g., in angiology and prenatal diagnostics. Aim: The aim of this study was to make a comparison between the informative ability of conventional 2D-ultrasound with that of 3D-ultrasound for investigations of joints and to determinate whether 3D-ultrasound can reveal additional diagnostic information. Method: During a defined period of time all clinically necessary ultrasonic investigations of joints were done with a 3D-sonograph. However, all data recorded need a manual post-processing stage for visualisation in a 3D-mode. Due to the small impedance differences between the tissue layers, an automated tissue differentiation was not possible. Results: The substantial advantage is that all the DEGUM standard levels can be derived from the scanning volume without conversion of the ultrasound head. Conclusion: At the current time the benefit of 3D-visualisation in the diagnostics of joints is small. The introduction of this technique to daily routine is not yet justified.
- 1 May 2007
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und Unfallchirurgie
- Vol. 145 (03) , 343-347
Stellenwert von 3D-Ultraschall in der Orthopädie
3D-Ultraschall gewinnt in vielen medizinischen Disziplinen, z. B. in der Angiologie und pränatalen Diagnostik, an zunehmender Bedeutung. Studienziel: Ziel dieser Studie war der Vergleich der Aussagefähigkeit am Bewegungsapparat zwischen konventionellen 2D-Verfahren und einem 3D-Verfahren mit vollautomatisierter Datenerfassung. Methode: Über einen definierten Zeitraum wurden alle sonografischen Untersuchungen am Stütz- und Bewegungsapparat mit einem 3D-fähigen Ultraschallgerät durchgeführt. Alle Datensätze wurden manuell im Sinne eines aufwendigen und zeitintensiven „Postprocessing“ nachgearbeitet, da aufgrund der geringen Impedanzunterschiede eine automatisierte Gewebedifferenzierung nicht möglich war. Ergebnisse: Der wesentliche Vorteil der 3D-basierten Datenakquisition war, dass alle erfassten DEGUM-Standardebenen aus dem Scanvolumen abgeleitet werden können und damit das Umsetzen des Schallkopfes zur Einstellung einer zweiten Ebene entfällt. Die selektive Darstellung relevanter Strukturen, z. B. einer Rotatorenmanschette, war nur nach manueller Nachbearbeitung möglich. Schlussfolgerung: Zum jetzigen Zeitpunkt sind die Vorteile der 3D-Darstellung in der Diagnostik des Bewegungsapparates zu gering, als dass ihre Einführung in die tägliche Routine gerechtfertigt ist. 3D-ultrasonic is gaining more and more significance in many medical disciplines, e. g., in angiology and prenatal diagnostics. Aim: The aim of this study was to make a comparison between the informative ability of conventional 2D-ultrasound with that of 3D-ultrasound for investigations of joints and to determinate whether 3D-ultrasound can reveal additional diagnostic information. Method: During a defined period of time all clinically necessary ultrasonic investigations of joints were done with a 3D-sonograph. However, all data recorded need a manual post-processing stage for visualisation in a 3D-mode. Due to the small impedance differences between the tissue layers, an automated tissue differentiation was not possible. Results: The substantial advantage is that all the DEGUM standard levels can be derived from the scanning volume without conversion of the ultrasound head. Conclusion: At the current time the benefit of 3D-visualisation in the diagnostics of joints is small. The introduction of this technique to daily routine is not yet justified.
- 1 March 2007
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 9 (1) , 63-68
Strukturierte Therapie traumatischer Plexus-brachialis-Läsionen
- 1 March 2007
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 9 (1) , 63-68
Strukturierte Therapie traumatischer Plexus-brachialis-Läsionen
- 1 January 2005
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 50 (10) , 337-342
Evaluation verfahrensspezifischer Risikopotentiale der Wasserabrasivstrahl – Osteotomie in-vivo / Evaluation of potential risks of abrasive water jet osteotomy in-vivo
Since the 80's the water jet scalpel is an established tool in some surgical fields. It is used in particular in visceral surgery for preparation of parenchymatous organs. By the addition of biocompatible abrasives, this technique is able to effectively machine hard biological tissues. Free defined cutting geometries can be realised in a non contact process. Therewith this method has crucial advantages compared to conventional osteotomy techniques and gives new impulses to the development in endoprosthetics and correction osteotomies of hollow bones. In the presented work the new developed abrasive water injection jet (AWIJ) was used the first time for in-vivo osteotomies. Aim of this study was the detection of potential thrombembolic effects and wash in effects of the cutting fluid. Hollow bones of the fore and hind leg of 20 house pigs were treated with the new cutting technique. Intraoperative documentation of relevant vital parameters was performed by a multi monitoring system. Thrombembolic effects during the osteotomy were detected by transthoracic Doppler ultrasonography and transesophagale echocardiography. The hollow bones were prepared in consideration of the vascularisation's protection especially in respect to the venous flow. Thrombembolic effects with temporary haemodynamic respectively respiratory consequences could be detected exclusively by using the so called "3-component jet", which consists of 90 vol % of air. The usage of an abrasive suspension enables the airfree dosing of dry soluable abrasives. Thrombembolic effects could not be monitored in this case. Intramedullary fluid in-wash effects as well as resulting electrolytic disorders could not be proven. For abrasive waterjet osteotomies with 3 component jet a relevant risk of thrombembolic effects could be shown. This knowledge has also to be considered for abdominal and neurosurgical applications in the future. Due to the usage of an abrasive suspension this risk can fully be avoided.
- 1 January 2005
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 50 (10) , 337-342
Evaluation verfahrensspezifischer Risikopotentiale der Wasserabrasivstrahl – Osteotomie in-vivo / Evaluation of potential risks of abrasive water jet osteotomy in-vivo
Since the 80's the water jet scalpel is an established tool in some surgical fields. It is used in particular in visceral surgery for preparation of parenchymatous organs. By the addition of biocompatible abrasives, this technique is able to effectively machine hard biological tissues. Free defined cutting geometries can be realised in a non contact process. Therewith this method has crucial advantages compared to conventional osteotomy techniques and gives new impulses to the development in endoprosthetics and correction osteotomies of hollow bones. In the presented work the new developed abrasive water injection jet (AWIJ) was used the first time for in-vivo osteotomies. Aim of this study was the detection of potential thrombembolic effects and wash in effects of the cutting fluid. Hollow bones of the fore and hind leg of 20 house pigs were treated with the new cutting technique. Intraoperative documentation of relevant vital parameters was performed by a multi monitoring system. Thrombembolic effects during the osteotomy were detected by transthoracic Doppler ultrasonography and transesophagale echocardiography. The hollow bones were prepared in consideration of the vascularisation's protection especially in respect to the venous flow. Thrombembolic effects with temporary haemodynamic respectively respiratory consequences could be detected exclusively by using the so called "3-component jet", which consists of 90 vol % of air. The usage of an abrasive suspension enables the airfree dosing of dry soluable abrasives. Thrombembolic effects could not be monitored in this case. Intramedullary fluid in-wash effects as well as resulting electrolytic disorders could not be proven. For abrasive waterjet osteotomies with 3 component jet a relevant risk of thrombembolic effects could be shown. This knowledge has also to be considered for abdominal and neurosurgical applications in the future. Due to the usage of an abrasive suspension this risk can fully be avoided.
- 1 October 2004
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 22 (5) , 426-430
Risk Evaluation of Thermal Injury to the Cervical Spine during Intradiscal Laser Application in Vitro
Objective: We aimed to investigate temperature distribution during laser and its possible thermal damage to the neurovascular structures. Background Data: Percutaneous laser disc decompression (PLDD) is now being performed as a minimally invasive intradiscal technique for the operative therapy of non-sequestered herniated cervical discs. As yet, no experimental basic research has been reported with regard to temperature rise and distribution in the cervical region during laser radiation. Materials and Methods: An in vitro laser procedure was performed on human cervical intervertebral discs under standardized conditions. A thermo-camera was used to monitor in real-time the zones sensitive to temperature increase. Results: Average intervertebral disc volume was 2000 mm 3 . With a total enegy conduction of 600 Joules, a temperature increase of around 30°C was shown with an initial temperature of 28°C at the posterior longitudinal ligament lying immediately in front of the myelon. The defect volume was less than 1% of the total intervertebral disc volume. Conclusion: If, during laser application, the total amount of conducted energy is too high, with an unfavorable position of the fibers in the intervertebral space, there is a risk of thermal damage to the spinal cord and nerve roots.
- 1 October 2004
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 22 (5) , 426-430
Risk Evaluation of Thermal Injury to the Cervical Spine during Intradiscal Laser Application in Vitro
Objective: We aimed to investigate temperature distribution during laser and its possible thermal damage to the neurovascular structures. Background Data: Percutaneous laser disc decompression (PLDD) is now being performed as a minimally invasive intradiscal technique for the operative therapy of non-sequestered herniated cervical discs. As yet, no experimental basic research has been reported with regard to temperature rise and distribution in the cervical region during laser radiation. Materials and Methods: An in vitro laser procedure was performed on human cervical intervertebral discs under standardized conditions. A thermo-camera was used to monitor in real-time the zones sensitive to temperature increase. Results: Average intervertebral disc volume was 2000 mm 3 . With a total enegy conduction of 600 Joules, a temperature increase of around 30°C was shown with an initial temperature of 28°C at the posterior longitudinal ligament lying immediately in front of the myelon. The defect volume was less than 1% of the total intervertebral disc volume. Conclusion: If, during laser application, the total amount of conducted energy is too high, with an unfavorable position of the fibers in the intervertebral space, there is a risk of thermal damage to the spinal cord and nerve roots.
- 1 October 2004
- Published by Mary Ann Liebert Inc in Photomedicine and Laser Surgery
- Vol. 22 (5) , 426-430
Risk Evaluation of Thermal Injury to the Cervical Spine during Intradiscal Laser Application in Vitro
- 1 October 2004
- Published by Mary Ann Liebert Inc in Photomedicine and Laser Surgery
- Vol. 22 (5) , 426-430
Risk Evaluation of Thermal Injury to the Cervical Spine during Intradiscal Laser Application in Vitro
- 1 July 2004
- Vol. 33 (7) , 351-62
Reconstructive operations for the upper limb after brachial plexus palsy.
Limited function due to paralysis following brachial plexus lesions can be improved by secondary operations of the bony and soft tissue. Between April 1994 and December 2000, 109 patients suffering from arm-plexus lesions underwent a total of 144 reconstructive operations guided by our concept of integrated therapy. The average age at the time of surgery was 32 years (range: 15-59). The following operations were performed: shoulder arthrodesis (23), trapezius transfer (74), rotation osteotomy of humerus (9), triceps to biceps transposition (9), transposition of forearm flexors or extensors (8), latissimus transfer (7), pectoralis transfer (1), teres major transfer (1), transposition of flexor carpi ulnaris to the tendons of extensor digitorum (10), and wrist arthrodesis (2). Prospectively, in all patients, the grade of muscle power of the affected upper extremity was evaluated prior to surgery. The follow-up period for all 144 operations was, on average, 22 months (range: 6-74). By means of operative measures, almost all patients obtained an improvement of shoulder function (100%) and stability (>90%), elbow flexion (85%), and hand, finger, and thumb (100%). When muscles malfunction after brachial plexus lesions, one should take into account the individual neuromuscular defect, passive joint function, and bony deformities; different procedures such as muscle transpositions, arthrodeses, and corrective osteotomies can then be performed to improve function of the upper extremity. Each form of operative treatment presents patients with certain benefits and all are integrated into a total treatment plan for the affected extremity.
- 1 July 2004
- Vol. 33 (7) , 351-62
Reconstructive operations for the upper limb after brachial plexus palsy.
Limited function due to paralysis following brachial plexus lesions can be improved by secondary operations of the bony and soft tissue. Between April 1994 and December 2000, 109 patients suffering from arm-plexus lesions underwent a total of 144 reconstructive operations guided by our concept of integrated therapy. The average age at the time of surgery was 32 years (range: 15-59). The following operations were performed: shoulder arthrodesis (23), trapezius transfer (74), rotation osteotomy of humerus (9), triceps to biceps transposition (9), transposition of forearm flexors or extensors (8), latissimus transfer (7), pectoralis transfer (1), teres major transfer (1), transposition of flexor carpi ulnaris to the tendons of extensor digitorum (10), and wrist arthrodesis (2). Prospectively, in all patients, the grade of muscle power of the affected upper extremity was evaluated prior to surgery. The follow-up period for all 144 operations was, on average, 22 months (range: 6-74). By means of operative measures, almost all patients obtained an improvement of shoulder function (100%) and stability (>90%), elbow flexion (85%), and hand, finger, and thumb (100%). When muscles malfunction after brachial plexus lesions, one should take into account the individual neuromuscular defect, passive joint function, and bony deformities; different procedures such as muscle transpositions, arthrodeses, and corrective osteotomies can then be performed to improve function of the upper extremity. Each form of operative treatment presents patients with certain benefits and all are integrated into a total treatment plan for the affected extremity.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 49 (1-2) , 18-21
Wärmeentwicklung bei der Wasser-Abrasivstrahl-Osteotomie / Temperature Measurements During Abrasive Water Jet Osteotomy
Working on bone is a major aspect of orthopaedic surgery. Despite its well-known appreciable thermal effects on the edges of the bone cut, the oscillating bone saw blade the oscillating saw remains the standard instrument both for cutting long bones and creating a bed for an endoprosthesis. The application of abrasive water jets offers the possibility of achieving an extremely precise curved cut in bone with no accompanying thermal effect. The thermographically measured absolute temperature increase at the cut edges seen with the water jet was 13 K maximum. The small process forces permit the application in automated handling systems.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 49 (1-2) , 18-21
Wärmeentwicklung bei der Wasser-Abrasivstrahl-Osteotomie / Temperature Measurements During Abrasive Water Jet Osteotomy
Working on bone is a major aspect of orthopaedic surgery. Despite its well-known appreciable thermal effects on the edges of the bone cut, the oscillating bone saw blade the oscillating saw remains the standard instrument both for cutting long bones and creating a bed for an endoprosthesis. The application of abrasive water jets offers the possibility of achieving an extremely precise curved cut in bone with no accompanying thermal effect. The thermographically measured absolute temperature increase at the cut edges seen with the water jet was 13 K maximum. The small process forces permit the application in automated handling systems.