Philipp A. Federspil
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Philipp A. Federspil has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
P. K. Plinkert
Universitätskliniken des Saarlandes, Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde
4 shared publicationsP K Plinkert
3 shared publicationsPeter K. Plinkert
Department of Otorhinolaryngology, Head & Neck Surgery, University of Saarland, Kirrberger Strasse, Homburg (Saar), Germany
2 shared publicationsB. Romeike
Universitätsklinik des Saarlandes
1 shared publicationBeate Plinkert
University of Saarland, Department of Oto-Rhino-Laryngology, Homburg, Germany
1 shared publicationD. Henrich
Universität Bayreuth
1 shared publication
Latest Publications
- 1 January 2004
- Vol. 58 (1) , 237-42
Robotic surgery in otorhinolaryngology.
Otoneurosurgery may greatly benefit from enhanced precision through robotics or from new procedures only made possible with robotic aid. Different implant cavities were milled by a serial robot (Stäubli RX 130) in formaldehyde fixed human skull bones. A variety of sensor data (force, momentum, temperature,...) were measured and evaluated. Ultrasound probes of different frequencies were used to measure skull bone thickness. With a serial robot Stäubli RX 130 it was possible to mill an exact implant cavity for various CI main modules in a human skull specimen. While milling with speed controlled by force feedback, the heat production was tremendously reduced as compared to the non controlled mode. Using coded excitation and a matched-filter technique, a 3D ultrasound scan of the skull bone could be performed in order to plan the drilling task for the robot by means of local navigation. This is the first functional robotic milling procedure for otoneurosurgery with force-based speed control in an experimental setting. Force feedback smoothes the robot's movements and reduces heat damage to surrounding tissues. Ultrasound navigation may replace the need for CT scanning in the future.
- 1 January 2004
- Vol. 58 (1) , 237-42
Robotic surgery in otorhinolaryngology.
Otoneurosurgery may greatly benefit from enhanced precision through robotics or from new procedures only made possible with robotic aid. Different implant cavities were milled by a serial robot (Stäubli RX 130) in formaldehyde fixed human skull bones. A variety of sensor data (force, momentum, temperature,...) were measured and evaluated. Ultrasound probes of different frequencies were used to measure skull bone thickness. With a serial robot Stäubli RX 130 it was possible to mill an exact implant cavity for various CI main modules in a human skull specimen. While milling with speed controlled by force feedback, the heat production was tremendously reduced as compared to the non controlled mode. Using coded excitation and a matched-filter technique, a 3D ultrasound scan of the skull bone could be performed in order to plan the drilling task for the robot by means of local navigation. This is the first functional robotic milling procedure for otoneurosurgery with force-based speed control in an experimental setting. Force feedback smoothes the robot's movements and reduces heat damage to surrounding tissues. Ultrasound navigation may replace the need for CT scanning in the future.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 49 (4) , 78-82
Restoring Hearing with Active Hearing Implants / Wiederherstellung des Gehörs mit aktiven Hörimplantaten
Due to shortcomings of conventional hearing aid technology, such as unsatisfactory sound quality due to limited frequency range and undesired distortion, occlusion of the outer ear canal, and acoustic feedback with high amplification, but also psychological aspects of stigmatization, a significant of patients in need of hearing aids are actually not wearing them. Active hearing implants can be distinguished in: (1) impedance transformation implants (ITI), (2) cochlear amplifier implants (CAI), (3) cochlear implants (CI), and (4) brain stem implants (BSI). Whereas ITI are designed for patients with middle ear hearing loss, CAI are intended to restore hearing in patients with inner ear hearing loss. Advantages of CAI may be: (1) improved sound fidelity, (2) no occlusion of the outer ear canal, (3) no feedback, and (4) invisibility. However, not all features are true for every device. CI replace inner ear function in deaf or almost deaf patients. This article gives an overview on the range of active hearing implants to restore hearing and outlines the future use of computer and robot aided surgery.
- 1 January 2004
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 49 (4) , 78-82
Restoring Hearing with Active Hearing Implants / Wiederherstellung des Gehörs mit aktiven Hörimplantaten
Due to shortcomings of conventional hearing aid technology, such as unsatisfactory sound quality due to limited frequency range and undesired distortion, occlusion of the outer ear canal, and acoustic feedback with high amplification, but also psychological aspects of stigmatization, a significant of patients in need of hearing aids are actually not wearing them. Active hearing implants can be distinguished in: (1) impedance transformation implants (ITI), (2) cochlear amplifier implants (CAI), (3) cochlear implants (CI), and (4) brain stem implants (BSI). Whereas ITI are designed for patients with middle ear hearing loss, CAI are intended to restore hearing in patients with inner ear hearing loss. Advantages of CAI may be: (1) improved sound fidelity, (2) no occlusion of the outer ear canal, (3) no feedback, and (4) invisibility. However, not all features are true for every device. CI replace inner ear function in deaf or almost deaf patients. This article gives an overview on the range of active hearing implants to restore hearing and outlines the future use of computer and robot aided surgery.
- 1 January 2004
- Published by Springer Nature
- p. 39-42
Multisensorische Überwachung robotergestützter Fräsvorgänge an der lateralen Schädelbasis
- 1 January 2004
- Published by Springer Nature
- p. 39-42
Multisensorische Überwachung robotergestützter Fräsvorgänge an der lateralen Schädelbasis
- 1 January 2004
- Published by Springer Nature
- p. 107-110
Extrakranielle Ausbreitung eines Meningeoms der vorderen Schädelbasis (Midfacial Degloving)
- 1 January 2004
- Published by Springer Nature
- p. 107-110
Extrakranielle Ausbreitung eines Meningeoms der vorderen Schädelbasis (Midfacial Degloving)
- 1 March 2003
- Published by Wiley in The Laryngoscope
- Vol. 113 (3) , 465-471
Development of the First Force‐Controlled Robot for Otoneurosurgery
Objective In some surgical specialties (eg, orthopedics), robots are already used in the operating room for bony milling work. Otological surgery and otoneurosurgery may also greatly benefit from the enhanced precision of robotics.Study Design Experimental study on robotic milling of oak wood and human temporal bone specimen.Methods A standard industrial robot with a six‐degrees‐of‐freedom serial kinematics was used, with force feedback to proportionally control the robot speed. Different milling modes and characteristic path parameters were evaluated to generate milling paths based on computer‐aided design (CAD) geometry data of a cochlear implant and an implantable hearing system.Results The best‐suited strategy proved to be the spiral horizontal milling mode with the burr held perpendicular to the temporal bone surface. To reduce groove height, the distance between paths should equal half the radius of the cutting burr head. Because of the vibration of the robot's own motors, a high oscillation of the SD of forces was encountered. This oscillation dropped drastically to nearly 0 Newton (N) when the burr head made contact with the dura mater, because of its damping characteristics. The cutting burr could be kept in contact with the dura mater for an extended period without damaging it, because of the burr's blunt head form. The robot moved the burr smoothly according to the encountered resistances.Conclusion The study reports the first development of a functional robotic milling procedure for otoneurosurgery with force‐based speed control. Future plans include implementation of ultrasound‐based local navigation and performance of robotic mastoidectomy.
- 1 March 2003
- Published by Wiley in The Laryngoscope
- Vol. 113 (3) , 465-471
Development of the First Force‐Controlled Robot for Otoneurosurgery
Objective In some surgical specialties (eg, orthopedics), robots are already used in the operating room for bony milling work. Otological surgery and otoneurosurgery may also greatly benefit from the enhanced precision of robotics.Study Design Experimental study on robotic milling of oak wood and human temporal bone specimen.Methods A standard industrial robot with a six‐degrees‐of‐freedom serial kinematics was used, with force feedback to proportionally control the robot speed. Different milling modes and characteristic path parameters were evaluated to generate milling paths based on computer‐aided design (CAD) geometry data of a cochlear implant and an implantable hearing system.Results The best‐suited strategy proved to be the spiral horizontal milling mode with the burr held perpendicular to the temporal bone surface. To reduce groove height, the distance between paths should equal half the radius of the cutting burr head. Because of the vibration of the robot's own motors, a high oscillation of the SD of forces was encountered. This oscillation dropped drastically to nearly 0 Newton (N) when the burr head made contact with the dura mater, because of its damping characteristics. The cutting burr could be kept in contact with the dura mater for an extended period without damaging it, because of the burr's blunt head form. The robot moved the burr smoothly according to the encountered resistances.Conclusion The study reports the first development of a functional robotic milling procedure for otoneurosurgery with force‐based speed control. Future plans include implementation of ultrasound‐based local navigation and performance of robotic mastoidectomy.
- Open Access
- 6 January 2003
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 8 (1) , 42-48
Experimental Robotic Milling in Skull-Base Surgery
Objective: In the field of otorhinolaryngology, a variety of skull implants have been developed to assist hearing-impaired or even deaf patients. The first step in the implantation procedure, and also in lateral skull-base surgery, is to drill the calvarian or mastoid bone. We intended to investigate the hitherto unknown parameters for performing this procedure and to establish the first set-up for robotic milling of the lateral skull base. Materials and Methods: Experimental milling of the skull base was conducted on two human specimens using a hexapod robot. Results: Optimized parameters were determined with a drill speed of 30,000 revolutions/min and a form feed rate of 5 mm/s for the calvarium and 1 mm/s for mastoid bone, respectively, in a spiral-path fashion. While using a cutting burr, mean force levels were 4.81 N for calvarian bone and 6.12 N for mastoid bone, respectively—well below our empirical limit of 10 N. However, maximum levels easily surpassed these limits, reaching 27.7 N. Conclusion: The prerequisites for robotic skull-base surgery were fulfilled. With further work to implement feedback of sensory input, robots may increase precision for various tasks in skull-base surgery.
- 6 January 2003
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 8 (1) , 42-48
Open AccessExperimental Robotic Milling in Skull-Base Surgery
Objective: In the field of otorhinolaryngology, a variety of skull implants have been developed to assist hearing-impaired or even deaf patients. The first step in the implantation procedure, and also in lateral skull-base surgery, is to drill the calvarian or mastoid bone. We intended to investigate the hitherto unknown parameters for performing this procedure and to establish the first set-up for robotic milling of the lateral skull base. Materials and Methods: Experimental milling of the skull base was conducted on two human specimens using a hexapod robot. Results: Optimized parameters were determined with a drill speed of 30,000 revolutions/min and a form feed rate of 5 mm/s for the calvarium and 1 mm/s for mastoid bone, respectively, in a spiral-path fashion. While using a cutting burr, mean force levels were 4.81 N for calvarian bone and 6.12 N for mastoid bone, respectively—well below our empirical limit of 10 N. However, maximum levels easily surpassed these limits, reaching 27.7 N. Conclusion: The prerequisites for robotic skull-base surgery were fulfilled. With further work to implement feedback of sensory input, robots may increase precision for various tasks in skull-base surgery.
- 1 May 2002
- Published by Springer Nature in HNO
- Vol. 50 (5) , 405-409
Knochenverankerte Hörgeräte immer beidseitig!
- 1 May 2002
- Published by Springer Nature in HNO
- Vol. 50 (5) , 405-409
Knochenverankerte Hörgeräte immer beidseitig!
- 1 April 2002
- Published by Springer Nature in HNO
- Vol. 50 (4) , 282-286
Tonsillenbiopsie zur Frühdiagnostik der Variante der Creutzfeldt-Jakob-Krankheit
- 1 April 2002
- Published by Springer Nature in HNO
- Vol. 50 (4) , 282-286
Tonsillenbiopsie zur Frühdiagnostik der Variante der Creutzfeldt-Jakob-Krankheit