TGTomas Gedrange

Tomas Gedrange

*This is an algorithmically generated author record based on publicly available information.

Tomas Gedrange has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 December 2009
      • p. 117-21

    Comparative animal study on hard tissue integration and bone formation of different Nobel Biocare implants.

    by T Gedrange, T Gredes, M Gredes, M R F Allegrini, G Borsos, A Vegh, M B Salles, F Heinemann, M Dominiak, S Allegrini

    Dental implantation aims at optimal and long-term hard tissue integration. Beside primary stability, loading time and other factors, e.g. the surface of the endosteal part of the implant, is a matter of special importance. In this animal trial, hard tissue integration of two different implant types was studied using radiological, histological and histomorphometric analysis. Two different implants with an oxidized surface (TiUnite; Nobel Biocare AB, Goteborg, Sweden, NobelReplace Tapered Groovy 4.3 x 10 mm and Replace Select Tapered 4.3 x 10 mm) were inserted into the right and left mandibles of 10 German domestic pigs between canine and premolar and immediately provided with a ceramic crown. The primary implant stability was determined using resonance frequency analysis. After 70 days, the test animals were killed and specimens were collected for histological and histomorphometric examination. All implants showed good primary stability after surgery. Histological and histomorphometrical analysis revealed no significant differences in the bone apposition. The immediate loading of the different implant types don't have any negative effects on the bone apposition in the period of 70 days. The long-term effects of immediate loading of these types of implant requires further studies.


  • Open Access

    Cryopreserved tissue engineered mucosa.

    by Gabriele Spoerl, Ronald Mai, Edith Klingner, Tomas Gedrange, Găźnter Lauer

    Single cells suspensions used for grafting in the clinical setting may be reliably cryopreserved by established protocols. However, for tissue engineered constructs which now also get used as grafts in the clinic such established protocols and assays which indicate graft viability and their function as graft do not exist. a) The purpose was to develop a cryoprotocol and an animal model to test the efficacy of tissue engineered to act as graft after cryopreservation. b) Therefore, tissue engineered mucosa grafts consisting of keratinocytes and fibroblasts grown in a collagen sponge were cryopreserved and grafted in the nude rat to test its efficacy to function as mucosa graft. At different points after cryopreservation the mucosa was grafted into the nude rats. Healing of grafts was allowed for one or three weeks. c) Sufficient cells survived the cryopreservation allowing for the development of epithelial-fibroblast tissue in the collagen sponge. After three weeks of healing the formation of mucosa tissue was more complete and more collagen sponge had disappeared. d) The nude rat model is suitable to assess the efficacy of tissue engineered mucosa to function as graft after cryopreservation. The formation of human epithelial-fibroblast tissue in vivo has to be interpreted as proof of principle that the approach of cryopreservation of tissue engineered grafts is working.


  • Analysis of colour stability of selected provisional prosthetic materials: an in vitro study

    by Ryszard Koczorowski, Kamila Linkowska-Świdzińska, Tomasz Gedrange, Teodor Świdziński

    Prosthetic restorative materials (that are) used for temporary fixed dentures tend to exhibit variable discolouration over several weeks of use. The aim of this study was to perform a spectrophotometric analysis of the influence of selected discolouring factors on the colour stability of provisional prosthetic materials in vitro. In the study, the following prosthetic materials for short-term use in the oral cavity were evaluated: Luxatemp, Structur 2S.C., Protemp II, Zhermacryl STC and Dentalon Plus. Samples of these materials were immersed in coffee, tea and dark fruit juice for 60 h at different pH values. Colour was evaluated by determining the monochromatic coefficients of light reflected by the samples, using a spectrophotometric method. Results received in artificial light (illuminant A) were compared with those obtained in daylight (illuminant D65). Changes in colour and its parameters according to the CIE L*a*b* system were analysed. The analysis (of the colour and colour parameters) of the tested materials in two types of light showed that Structur displayed the greatest tendency to discolouration and that the least tendency to discolouration was exhibited by Dentalon Plus. The fact that colour parameters obtained in two types of light were not identical suggests that changes in the colour of the same material may be perceived differently, depending on the illuminant. Provisional prosthetic materials show variable colour stability under different conditions in the oral cavity. The colour of prosthetic materials may be perceived differently, depending on the illuminant and the effect of the environment in which they are used.


    • 1 November 2008
      • p. 87-94

    Evaluation of shape and size changes of bone and remodelled bone substitute after different fixation methods.

    by T Gedrange, R Mai, F Mack, M Zietek, G Borsos, A Vegh, A Spassov, T Gredes

    Suitable tissue fixation is indispensable to histological analysis. This investigation, therefore, sought to evaluate changes of shape and size of bone specimens and remodelled bone substitute material following different fixation methods. Mandibular bones of 9 pigs (Sus scrofa domesticus) served as specimens. Two mandibular premolars were extracted respectively and the extraction alveoli were filled with synthetic bone substitute material. The samples were collected after 70 days. Fixation of 6 specimens respectively was done for 7 days in 4% formalin (formaldehyde), 70% ethanol and glycerol at 18 degrees C room temperature. The samples were radiographically examined before and after fixation using a reference specimen and subsequently underwent histological analysis. After fixation in formalin, the samples showed no size changes. After fixation in glycerol, morphological analysis revealed minor shape changes. Fixation in ethanol causes shrinking of the tissue specimens. Histological inspection of the tissues shows no morphological changes except slight shrinking. In conclusion there is no universal fixative that could met all requirements and permited proper examination without affecting tissues or bone specimens.


  • Finite element representation of bone substitute remodelling in the jaw bone

    by Tomasz Gedrange, Ronald Mai, Jens Weingaertner, Volker Hietschold, Christoph Bourauel, Winnie Pradel, Günter Lauer, Peter Proff

    The finite element (FE) method was originally developed on a physical basis for the computation of structure-mechanical problems. Meanwhile, it has been widely applied to medical issues. This study sought a suitable method to build a FE model for remodelling processes in osseous defects supplemented with bone substitute material. For this purpose, the second right premolars were extracted from four pig mandibles (Sus scrofa domesticus) and the extraction alveoli were provided with synthetic bone substitute material. After 70 days, a segmented osteotomy of this area was performed for specimen collection. Radiographs of the specimens were taken in defined planes before and after fixation and embedded with Technovit 9100. Fixation-related shrinkage was quantified from the radiographs using reference lines. Computer tomographic (CT) and microCT images of the fixed and embedded specimens were obtained. From these data, a FE model was built. The construction of a FE model is sufficient to represent bone remodelling after supply of bone substitute material. The use of microCT data permits building a clearly more precise model.


  • Open Access

    Early loading of plalatal implants (ortho-type II) a prospective multicenter randomized controlled clinical trial

    by Britta A Jung, Heinrich Wehrbein, Werner Hopfenmüller, Winfried Harzer, Tomasz Gedrange, Peter Diedrich, Martin Kunkel

    In orthodontic treatment, anchorage control is a fundamental aspect. Usually conventional mechanism for orthodontic anchorage control can be either extraoral or intraoral that is headgear or intermaxillary elastics. Their use are combined with various side effects such as tipping of occlusal plane or undesirable movements of teeth. Especially in cases, where key-teeth are missing, conventional anchorage defined as tooth-borne anchorage will meet limitations. Therefore, the use of endosseous implants for anchorage purposes are increasingly used to achieve positional stability and maximum anchorage.


  • Correlation of MRT imaging with real-time axiography of TMJ clicks

    by Olga Tymofiyeva, Peter Proff, Ernst-Jürgen Richter, Peter Jakob, Jochen Fanghänel, Tomas Gedrange, Kurt Rottner


  • Morphological structures and protrusive cranial border guidance of the temporomandibular joint of Cercopithecus mona

    by Susanne Zech, Julia Fricke, Jochen Fanghänel, Henning Dathe, Dankmar Ihlow, Kirsten M. Thieme, Dietmar Kubein-Meesenburg, Peter Proff, Tomas Gedrange, Hans Nägerl