Lei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lei Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Fei Xu
National Engineering Research Center for Healthcare Devices, Guangdong Key Lab of Medical Electronic Instruments and Polymer Material Products, Guangdong Institute of Medical Instruments, Institute of Medicine and Health, Guangdong Academy of Sciences, Guangzhou, China
1 shared publicationGuixiang Li
National Engineering Research Center for Healthcare Devices, Guangdong Key Lab of Medical Electronic Instruments and Polymer Material Products, Guangdong Institute of Medical Instruments, Institute of Medicine and Health, Guangdong Academy of Sciences, Guangzhou, China
1 shared publicationHai Wang
Tianbang National Engineering Research Center of Membrane Technology Co., Ltd., Dalian 116023, Liaoning, China
1 shared publicationHong Wu
Sinopec Zhenhai Refining and Chemical Company Limited, Ningbo 315200, Zhejiang, China
1 shared publication- Jun Chen
Guangdong Institute of Medical Instruments, Guangzhou, China
1 shared publication - Kai Wu
School of Biomedical Sciences and Engineering, South China University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- Open Access
- 30 July 2021
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 21 (S2) , 1-15
A particle swarm optimization improved BP neural network intelligent model for electrocardiogram classification
Background: As proven to reflect the work state of heart and physiological situation objectively, electrocardiogram (ECG) is widely used in the assessment of human health, especially the diagnosis of heart disease. The accuracy and reliability of abnormal ECG (AECG) decision depend to a large extent on the feature extraction. However, it is often uneasy or even impossible to obtain accurate features, as the detection process of ECG is easily disturbed by the external environment. And AECG got many species and great variation. What’s more, the ECG result obtained after a long time past, which can not reach the purpose of early warning or real-time disease diagnosis. Therefore, developing an intelligent classification model with an accurate feature extraction method to identify AECG is of quite significance. This study aimed to explore an accurate feature extraction method of ECG and establish a suitable model for identifying AECG and the diagnosis of heart disease. Methods: In this research, the wavelet combined with four operations and adaptive threshold methods were applied to filter the ECG and extract its feature waves first. Then, a BP neural network (BPNN) intelligent model and a particle swarm optimization (PSO) improved BPNN (PSO-BPNN) intelligent model based on MIT-BIH open database was established to identify ECG. To reduce the complexity of the model, the principal component analysis (PCA) was used to minimize the feature dimension. Results: Wavelet transforms combined four operations and adaptive threshold methods were capable of ECG filtering and feature extraction. PCA can significantly deduce the modeling feature dimension to minimize the complexity and save classification time. The PSO-BPNN intelligent model was suitable for identifying five types of ECG and showed better effects while comparing it with the BPNN model. Conclusion: In summary, it was further concluded that the PSO-BPNN intelligent model would be a suitable way to identify AECG and provide a tool for the diagnosis of heart disease.
- 30 July 2021
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 21 (S2) , 1-15
Open AccessA particle swarm optimization improved BP neural network intelligent model for electrocardiogram classification
Background: As proven to reflect the work state of heart and physiological situation objectively, electrocardiogram (ECG) is widely used in the assessment of human health, especially the diagnosis of heart disease. The accuracy and reliability of abnormal ECG (AECG) decision depend to a large extent on the feature extraction. However, it is often uneasy or even impossible to obtain accurate features, as the detection process of ECG is easily disturbed by the external environment. And AECG got many species and great variation. What’s more, the ECG result obtained after a long time past, which can not reach the purpose of early warning or real-time disease diagnosis. Therefore, developing an intelligent classification model with an accurate feature extraction method to identify AECG is of quite significance. This study aimed to explore an accurate feature extraction method of ECG and establish a suitable model for identifying AECG and the diagnosis of heart disease. Methods: In this research, the wavelet combined with four operations and adaptive threshold methods were applied to filter the ECG and extract its feature waves first. Then, a BP neural network (BPNN) intelligent model and a particle swarm optimization (PSO) improved BPNN (PSO-BPNN) intelligent model based on MIT-BIH open database was established to identify ECG. To reduce the complexity of the model, the principal component analysis (PCA) was used to minimize the feature dimension. Results: Wavelet transforms combined four operations and adaptive threshold methods were capable of ECG filtering and feature extraction. PCA can significantly deduce the modeling feature dimension to minimize the complexity and save classification time. The PSO-BPNN intelligent model was suitable for identifying five types of ECG and showed better effects while comparing it with the BPNN model. Conclusion: In summary, it was further concluded that the PSO-BPNN intelligent model would be a suitable way to identify AECG and provide a tool for the diagnosis of heart disease.
- 1 December 2008
- Published by Elsevier in Journal of Natural Gas Chemistry
- Vol. 17 (4) , 409-414
Fuzzy self-tuning PID control of the operation temperatures in a two-staged membrane separation process
- 1 December 2008
- Published by Elsevier in Journal of Natural Gas Chemistry
- Vol. 17 (4) , 409-414
Fuzzy self-tuning PID control of the operation temperatures in a two-staged membrane separation process