PSPeter M. A. Sherwood

Peter M. A. Sherwood

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter M. A. Sherwood has a total of 152 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    What more can be done with XPS? Highly informative but underused approaches to XPS data collection and analysis

    by Donald R. Baer, Merve Taner Camci, David J. H. Cant, Scott A. Chambers, Hagai Cohen, Pinar Aydogan Gokturk, David J. Morgan, Andrey Shchukarev, Peter M. A. Sherwood, Sefik Suzer, et al.

    Because of the importance of surfaces and interfaces in many scientific and technological areas, the use of x-ray photoelectron spectroscopy (XPS) has been growing exponentially. Although XPS is being used to obtain useful information about the surface composition of samples, much more information about materials and their properties can be extracted from XPS data than commonly obtained. This paper describes some of the areas where alternative analysis methods or experimental design can obtain information about the near-surface region of a sample, often information not available in other ways. Experienced XPS analysts are familiar with many of these methods, but they may not be known to new or casual XPS users, and sometimes, they have not been used because of an inappropriately assumed complexity. The information available includes optical, electronic, and electrical properties; nanostructure; expanded chemical information; and enhanced analysis of biological materials and solid/liquid interfaces. Many of these analyses can be conducted on standard laboratory XPS systems, with either no or relatively minor system alterations. Topics discussed include (1) considerations beyond the “traditional” uniform surface layer composition calculation, (2) using the Auger parameter to determine a sample property, (3) use of the D parameter to identify sp2 and sp3 carbon information, (4) information from the XPS valence band, (5) using cryocooling to expand range of samples that can be analyzed and minimize damage, and (6) using electrical potential effects on XPS signals to extract chemically resolved electrical measurements including band alignment and electrical property information.


  • What's in a Name? “ESCA” or “XPS”? A Discussion of Comments Made by Kai Siegbahn More Than Four Decades Ago Regarding the Name of the Technique

    by Joshua W. Pinder, Braxton Kulbacki, Donald R. Baer, Mark Biesinger, James Castle, David G. Castner, Christopher D. Easton, John T. Grant, Grzegorz Greczynski, Sarah L. Harmer, et al.

    In an interview in 1982, which was 1 year after he shared the Nobel Prize, Kai Siegbahn was asked about his opinion regarding the name of the technique he had developed. Siegbahn had named it “electron spectroscopy for chemical analysis” (ESCA), but the community was choosing to call it “X‐ray photoelectron spectroscopy” (XPS). Now, more than 40 years later, 20 XPS experts have given their opinions on Siegbahn's response and the name of the technique. Some of these participants have been doing XPS for many years and have provided a historical perspective on this issue. While there is no call in these comments for the community to return to “ESCA”—“XPS” is regarded as a more than an adequate name, and insisting on a name change at this point in time would probably only create confusion. However, some of the participants of this study still consider “ESCA” to be an acceptable way to refer to the technique, especially when it is used in a chemical context.


  • Erratum: “Practical guide for curve fitting in x-ray photoelectron spectroscopy” [J. Vac. Sci. Technol. A 38, 061203 (2020)]

    by George H. Major, Neal Fairley, Peter M. A. Sherwood, Matthew R. Linford, Jeff Terry, Vincent Fernandez, Kateryna Artyushkova


  • Erratum: “Practical guides for x-ray photoelectron spectroscopy: First steps in planning, conducting, and reporting XPS measurements” [J. Vac. Sci. Technol. A 37, 031401 (2019)]

    by Donald R. Baer, Kateryna Artyushkova, Christopher Richard Brundle, James E. Castle, Mark H. Engelhard, Karen J. Gaskell, John T. Grant, Richard T. Haasch, Matthew R. Linford, Cedric J. Powell, et al.


  • Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

    by Mark H. Engelhard, Donald R. Baer, Alberto Herrera-Gomez, Peter M. A. Sherwood

    Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. This introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.


  • The use and misuse of curve fitting in the analysis of core X‐ray photoelectron spectroscopic data

    by Peter M.A. Sherwood

    Core X‐ray photoelectron spectroscopic (XPS) data often contain overlapping chemically shifted peaks that differ in their width, peak shape, and intensity. The spectra may be complicated by the presence of satellite and multiplet splitting features as well as from the X‐ray satellites that arise when achromatic X‐radiation is used. Curve fitting has been extensively used for more than the past 50 years as a means of extracting chemical information from the overlapping features in core XPS. Our understanding of the key components of this approach, such as the fitting function and the spectral background, has improved substantially over the years. XPS is now the most widely used surface analytical method, and many users often have their principal expertise in other areas. While the associated computer software in most XPS instruments has powerful data analysis techniques, including curve fitting, provided by the manufacturer or by a separate commercial source, the application of these techniques may not always be appropriately applied. This perspective article gives the author's view of the main issues that impact the use of curve fitting, together with a description of some approaches that misuse curve fitting leading to erroneous conclusions about the surface chemistry. The article is illustrated by examples showing the fitting of various types of spectra using true Voigt functions.


  • Rapid evaluation of the Voigt function and its use for interpreting X‐ray photoelectron spectroscopic data

    by Peter M.A. Sherwood

    While the Voigt function is recognized as the best function to represent the photoelectron spectroscopic process, it is less frequently used because it cannot be represented as an analytical function and thus has to be evaluated numerically. This paper shows how the true Voigt function can be calculated rapidly with approximately the same speed as pseudo‐Voigt functions by using approaches that have been used by the astronomical sciences community. The Voigt function is calculated using code previously published by Wells. The paper describes a method for calculating the function to generate photoelectron peaks for curve fitting X‐ray photoelectron spectroscopic data. An appendix is provided with the listing of a Fortran 90 program which uses the subroutine HUMDEV published by Wells. Examples of using this approach for the fitting of experimental core X‐ray photoelectron spectroscopic data are presented, and the fits compared with fits using a pseudo Voigt product function. The use of the true Voigt function in the calculation of spectra in the core and valence band region is also described and illustrated by comparing the calculated spectra with experimental spectra.


  • Photoelectron spectroscopic studies of the formation of hydroxyapatite films on titanium pretreated with etidronic acid

    by F. Gao, Peter M. A. Sherwood

    X‐ray photoelectron spectroscopy in the core and valence band region was used to study the formation of hydroxyapatite films on the surface of titanium. The approach used achieves the adhesion of hydroxyapatite by the initial formation of a thin, mainly oxide‐free, etidronate film on the metal. In this approach, it was not possible to prepare hydroxyapatite films of any reasonable thickness on the titanium surface without prior treatment with etidronic acid. Because hydroxyapatite is a principal component of teeth and bones, it is likely that the coated metals will have desirable biocompatible properties. The hydroxyapatite film showed no changes when the film was exposed to air, water, and 1 m sodium chloride solution as representative components of the environment of the film in the human body. These films formed on titanium may find application in medical implants. The thin hydroxyapatite and etidronate film on the metal show differential charging effects that caused a doubling of some of the spectral features. Copyright © 2012 John Wiley & Sons, Ltd.


  • Photoelectron spectroscopic studies of the formation of hydroxyapatite films on 316L stainless steel pretreated with etidronic acid

    by Feng Gao, Peter M. A. Sherwood

    The valence band and core‐level X‐ray photoelectron spectroscopy was used to probe hydroxyapatite films formed on the surface of stainless steel. These films formed on steel may find application in medical implants. The key to the successful adhesion of the hydroxyapatite films is shown to be the initial formation of a thin, oxide‐free etidronate film on the metal. It was not found possible to prepare the hydroxyapatite films directly on the metal surfaces. Since hydroxyapatite is a key component of bone and teeth, it is likely that the coated metals will have desirable biocompatible properties. The hydroxyapatite film was exposed to air, water, and 1M sodium chloride solution as representative components of the environment of the film in the human body, and these exposures led to no detectable decomposition of the film. The thin hydroxyapatite and etidronate film on the metal show differential charging effects that caused a doubling of the peaks in some core level spectra. The valence band spectra proved especially valuable in the identification of the surface chemistry of the films, and these spectra were interpreted by comparing the experimental spectra with spectra calculated using band structure calculations which showed good agreement with experiment. The calculated spectrum of etidronic acid was found to be significantly different to that of etidronate. Copyright © 2012 John Wiley & Sons, Ltd.