Younes Boudjemline
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Younes Boudjemline has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Daniel Sidi
Service de Cardiologie Pédiatrie, Hôpital Necker-Enfants Malades, Assistance Publique Hôpitaux de Paris, and Faculté de Médecine Necker Enfants Malades, Université Paris V, Paris, France
13 shared publicationsDamien Bonnet
Service de Cardiologie Pédiatrie, Hôpital Necker-Enfants Malades, Assistance Publique Hôpitaux de Paris, and Faculté de Médecine Necker Enfants Malades, Université Paris V, Paris, France
9 shared publications- Damien Bonnet
Centre de Référence Malformations Cardiaques Congénitales Complexes (M3C), Hôpital Universitaire Necker-Enfants Malades, AP-HP, 75015 Paris, France; Université de Paris Cité, 75006 Paris, France
9 shared publications Gabriella Agnoletti
AP-HP, Hôpital Necker Enfants Malades, Service de Cardiologie Pédiatrique, Paris, France
7 shared publicationsPhilipp Bonhoeffer
Cardiothoracic Unit, Great Ormond Street Hospital, London, United Kingdom
7 shared publicationsEmmanuelle Pineau
Service de Cardiologie Pédiatrie, Hôpital Necker-Enfants Malades, Assistance Publique Hôpitaux de Paris, and Faculté de Médecine Necker Enfants Malades, Université Paris V, Paris, France
4 shared publications
Latest Publications
- 1 September 2017
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 9 (4) , 270
Cardiac catheterization in infants weighing less than 2500g
- 1 September 2017
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 9 (4) , 270
Cardiac catheterization in infants weighing less than 2500g
- 1 September 2016
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 8 (5) , 10-11
Percutaneous pulmonary Melody valve implantation in conduit below 16mm
- 1 September 2016
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 8 (5) , 10-11
Percutaneous pulmonary Melody valve implantation in conduit below 16mm
- 7 August 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (4) , 485-500
Blood Flow Simulations for the Design of Stented Valve Reducer in Enlarged Ventricular Outflow Tracts
Tetralogy of Fallot is a congenital heart disease characterized over time, after the initial repair, by the absence of a functioning pulmonary valve, which causes regurgitation, and by progressive enlargement of the right ventricle outflow tract (RVOT). Due to this pathological anatomy, available transcatheter valves are usually too small to be deployed there. To avoid surgical valve replacement, an alternative consists in implanting a reducer prior to or in combination with the valve. It has been shown in animal experiments to be promising, but with some limitations. The effect of a percutaneous pulmonary valve reducer on hemodynamics in enlarged RVOT is thus studied by computational modeling. To this aim, blood flow in the RVOT is modeled with CFD coupled to a simplified valve model and 0D downstream models. Simulations are performed in an image-based geometry and boundary conditions tuned to reproduce the pathological flow without the device. Different device designs are built and compared with the initial device-free state, or with the reducer alone. Results suggest that pressure loss is higher for the reducer alone than for the full device, and that the latter successfully restores hemodynamics to a healthy state and induces a more symmetric flow in the pulmonary arteries. Moreover, pressure forces on the reducer and on the valve have the same magnitudes. Migration would occur towards the right ventricle rather than the pulmonary arteries. Results support the thesis that the reducer does not introduce clinically significant pressure gradients, as was found in animal experiments. Such study could help transfer to patients.
- 7 August 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (4) , 485-500
Blood Flow Simulations for the Design of Stented Valve Reducer in Enlarged Ventricular Outflow Tracts
Tetralogy of Fallot is a congenital heart disease characterized over time, after the initial repair, by the absence of a functioning pulmonary valve, which causes regurgitation, and by progressive enlargement of the right ventricle outflow tract (RVOT). Due to this pathological anatomy, available transcatheter valves are usually too small to be deployed there. To avoid surgical valve replacement, an alternative consists in implanting a reducer prior to or in combination with the valve. It has been shown in animal experiments to be promising, but with some limitations. The effect of a percutaneous pulmonary valve reducer on hemodynamics in enlarged RVOT is thus studied by computational modeling. To this aim, blood flow in the RVOT is modeled with CFD coupled to a simplified valve model and 0D downstream models. Simulations are performed in an image-based geometry and boundary conditions tuned to reproduce the pathological flow without the device. Different device designs are built and compared with the initial device-free state, or with the reducer alone. Results suggest that pressure loss is higher for the reducer alone than for the full device, and that the latter successfully restores hemodynamics to a healthy state and induces a more symmetric flow in the pulmonary arteries. Moreover, pressure forces on the reducer and on the valve have the same magnitudes. Migration would occur towards the right ventricle rather than the pulmonary arteries. Results support the thesis that the reducer does not introduce clinically significant pressure gradients, as was found in animal experiments. Such study could help transfer to patients.
- 1 May 2012
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 25 (5) , 511-517
Right Ventricular Systolic Strain Is Altered in Children with Sickle Cell Disease
- 1 May 2012
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 25 (5) , 511-517
Right Ventricular Systolic Strain Is Altered in Children with Sickle Cell Disease
- 1 April 2012
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 7 (12) , 1428-1434
Midterm results of percutaneous closure of very large atrial septal defects in children: role of multislice computed tomography
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 April 2012
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 7 (12) , 1428-1434
Midterm results of percutaneous closure of very large atrial septal defects in children: role of multislice computed tomography
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 31 January 2011
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 3 (1) , 98
295 Pulmonary arterial hypertension after bone marrow transplantation in children
- 31 January 2011
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 3 (1) , 98
295 Pulmonary arterial hypertension after bone marrow transplantation in children
- 26 August 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 139 (1) , 198-208
Transcatheter valve insertion in a model of enlarged right ventricular outflow tracts
- 26 August 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 139 (1) , 198-208
Transcatheter valve insertion in a model of enlarged right ventricular outflow tracts
- 31 July 2009
- Published by Springer Nature
- p. 75-90
Virtual Pulmonary Valve Replacement Interventions with a Personalised Cardiac Electromechanical Model
- 31 July 2009
- Published by Springer Nature
- p. 75-90
Virtual Pulmonary Valve Replacement Interventions with a Personalised Cardiac Electromechanical Model
- 20 June 2007
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 17 (4) , 452-453
Unusual flow of blood to the pulmonary arteries through a large coronary arterial fistula in the setting of complex congenital cardiac disease
- 20 June 2007
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 17 (4) , 452-453
Unusual flow of blood to the pulmonary arteries through a large coronary arterial fistula in the setting of complex congenital cardiac disease