Airton Ramos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Airton Ramos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Ota Hisayasu Suzuki
Institute of Biomedical Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil
2 shared publications - Jefferson Luiz Brum Marques
Institute of Biomedical Engineering, Department of Electrical and Electronic Engineering, Federal University of Santa Catarina, Florianópolis, Brazil
2 shared publications - Andrea Lima dos Santos Schneider
Universidade da Região de Joinville, Brasil; Universidade da Região de Joinville, Brasil
1 shared publication - Heric Farias D.
State University of Santa Catarina
1 shared publication Julia G. B. Wolff
Department of Electrical Engineering, University of Santa Catarina State, Joinville, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 December 2013
- Published by FapUNIFESP (SciELO) in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
- Vol. 12 (2) , 647-654
Numerical analysis of impedance spectra of yeast suspensions
Analysis of impedance spectrum of electroporated biological cell suspensions allows evaluating the state of permeabilization produced by the applied electric field. In this article we used a genetic algorithm to determine parameters of a proposed model for the impedance of suspension adjusting them numerically in order to minimize the error in relation to experimental spectra of Kluyveromyces marxianus CBS 6556 yeasts suspended in distilled water. It was possible to determine the variation of conductivity of suspension avoiding the influence of electrode polarization and dielectric dispersion due to interfacial and diffusion polarization on the cell surface. It was observed that the conductivity in the range of 1 to 100 KHz increases 2.5 times with pulses of 400 KV/m.
- 1 December 2013
- Published by FapUNIFESP (SciELO) in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
- Vol. 12 (2) , 647-654
Open AccessNumerical analysis of impedance spectra of yeast suspensions
Analysis of impedance spectrum of electroporated biological cell suspensions allows evaluating the state of permeabilization produced by the applied electric field. In this article we used a genetic algorithm to determine parameters of a proposed model for the impedance of suspension adjusting them numerically in order to minimize the error in relation to experimental spectra of Kluyveromyces marxianus CBS 6556 yeasts suspended in distilled water. It was possible to determine the variation of conductivity of suspension avoiding the influence of electrode polarization and dielectric dispersion due to interfacial and diffusion polarization on the cell surface. It was observed that the conductivity in the range of 1 to 100 KHz increases 2.5 times with pulses of 400 KV/m.
- 14 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (10) , 2965-2973
Sinusoidal Signal Analysis of Electroporation in Biological Cells
Conductivity measurements in suspensions of biological cells have been used since many years for electroporation effectiveness evaluation. However, conductivity modeling by means of instantaneous values of current and voltage during pulse application does not take into account the effects of the sample reactance and the dielectric dispersion of the medium. This can lead to misinterpretation in the electroporation analysis. The electrical modeling and characterization of electroporation using sinusoidal signal analysis at 10 kHz proposed in this paper allows us to avoid distortions due to reactive effects of the sample. A simple equation establishes the relation between suspension conductivity and membrane conductance. This model was used in experiments with suspensions of yeast cells and applied electric fields of up to 450 kV/m for 1 ms. The analysis using the proposed model resulted in membrane conductance values of up to 8000 S/m2 and allowed estimating the distribution profile of conductance on the cell membrane.
- 14 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (10) , 2965-2973
Sinusoidal Signal Analysis of Electroporation in Biological Cells
Conductivity measurements in suspensions of biological cells have been used since many years for electroporation effectiveness evaluation. However, conductivity modeling by means of instantaneous values of current and voltage during pulse application does not take into account the effects of the sample reactance and the dielectric dispersion of the medium. This can lead to misinterpretation in the electroporation analysis. The electrical modeling and characterization of electroporation using sinusoidal signal analysis at 10 kHz proposed in this paper allows us to avoid distortions due to reactive effects of the sample. A simple equation establishes the relation between suspension conductivity and membrane conductance. This model was used in experiments with suspensions of yeast cells and applied electric fields of up to 450 kV/m for 1 ms. The analysis using the proposed model resulted in membrane conductance values of up to 8000 S/m2 and allowed estimating the distribution profile of conductance on the cell membrane.
- 13 January 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (2) , 233-240
Numerical modeling of magnetic induction tomography using the impedance method
- 13 January 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (2) , 233-240
Numerical modeling of magnetic induction tomography using the impedance method
- 17 September 2010
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 81 (4) , 860-874
A new approach to the solution of electromagnetic problems with the impedance method
- 17 September 2010
- Published by Elsevier in Mathematics and Computers in Simulation
- Vol. 81 (4) , 860-874
A new approach to the solution of electromagnetic problems with the impedance method
- 6 March 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (4) , 311-319
Improved numerical approach for electrical modeling of biological cell clusters
This article presents an efficient numerical approach to simulate the process of polarization and ion conduction in membranes of biological cells subjected to intense electric fields. The proposed method uses Coulomb’s law to calculate the electric field on the surface of the cell membrane and the continuity equation for calculating the difference in electric potential between the faces of the membrane. The behavior of the membrane conductance is described by a model of electroporation proposed in literature. This method provides results that agree well with the analytical model of polarization of an isolated cell suspended in electrolytic solution and also provides results for the conductance of the membrane during electroporation of cells in concentrated suspensions that agree with experimental results already published.
- 6 March 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (4) , 311-319
Improved numerical approach for electrical modeling of biological cell clusters
This article presents an efficient numerical approach to simulate the process of polarization and ion conduction in membranes of biological cells subjected to intense electric fields. The proposed method uses Coulomb’s law to calculate the electric field on the surface of the cell membrane and the continuity equation for calculating the difference in electric potential between the faces of the membrane. The behavior of the membrane conductance is described by a model of electroporation proposed in literature. This method provides results that agree well with the analytical model of polarization of an isolated cell suspended in electrolytic solution and also provides results for the conductance of the membrane during electroporation of cells in concentrated suspensions that agree with experimental results already published.
- 1 January 2007
- Published by Taylor & Francis in Electromagnetic Biology and Medicine
- Vol. 26 (3) , 239-250
Modeling Environment for Numerical Simulation of Applied Electric Fields on Biological Cells
The application of electric pulses in cells increases membrane permeability. This phenomenon is called electroporation. Current electroporation models do not explain all experimental findings: part of this problem is due to the limitations of numerical methods. The Equivalent Circuit Method (ECM) was developed in an attempt to solve electromagnetic problems in inhomogeneous and anisotropic media. ECM is based on modeling of the electrical transport properties of the medium by lumped circuit elements as capacitance, conductance, and current sources, representing the displacement, drift, and diffusion current, respectively. The purpose of the present study was to implement a 2-D cell Model Development Environment (MDE) of ionic transport process, local anisotropy around cell membranes, biological interfaces, and the dispersive behaviour of tissues. We present simulations of a single cell, skeletal muscle, and polygonal cell arrangement. Simulation of polygonal form indicates that the potential distribution depends on the geometrical form of cell. The results demonstrate the importance of the potential distributions in biological cells to provide strong evidences for the understanding of electroporation.
- 1 January 2007
- Published by Taylor & Francis in Electromagnetic Biology and Medicine
- Vol. 26 (3) , 239-250
Modeling Environment for Numerical Simulation of Applied Electric Fields on Biological Cells
The application of electric pulses in cells increases membrane permeability. This phenomenon is called electroporation. Current electroporation models do not explain all experimental findings: part of this problem is due to the limitations of numerical methods. The Equivalent Circuit Method (ECM) was developed in an attempt to solve electromagnetic problems in inhomogeneous and anisotropic media. ECM is based on modeling of the electrical transport properties of the medium by lumped circuit elements as capacitance, conductance, and current sources, representing the displacement, drift, and diffusion current, respectively. The purpose of the present study was to implement a 2-D cell Model Development Environment (MDE) of ionic transport process, local anisotropy around cell membranes, biological interfaces, and the dispersive behaviour of tissues. We present simulations of a single cell, skeletal muscle, and polygonal cell arrangement. Simulation of polygonal form indicates that the potential distribution depends on the geometrical form of cell. The results demonstrate the importance of the potential distributions in biological cells to provide strong evidences for the understanding of electroporation.