Wolfgang Haigis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wolfgang Haigis has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
B. Lege
University Eye Clinic, Josef-Schneider-Strasse 11, 97080 Würzburg, GermanyTel.: +49-931-2015640 Fax: +49-931-2012454
1 shared publicationB. Schneider
University Eye Clinic, Josef-Schneider-Strasse 11, 97080 Würzburg, GermanyTel.: +49-931-2015640 Fax: +49-931-2012454
1 shared publicationN. Miller
University Eye Clinic, Josef-Schneider-Strasse 11, 97080 Würzburg, GermanyTel.: +49-931-2015640 Fax: +49-931-2012454
1 shared publication
Latest Publications
- 1 December 2012
- p. 59-64
Influence of axial length on IOL constants.
In IOL formulas, the lens itself is represented by specific constants. Usually, these are given by the manufacturers as averages that need customization to allow for individual measurement setups. Apart from the instrumentation, patient characteristics such as axial length distribution may influence IOL constants, as demonstrated in this study. The effect of axial length on different IOL constants was studied on model calculations in theoretical ametropic eyes derived from the standard Gullstrand eye as well as in clinical results obtained for different surgical centers within the ULIB project in optical biometry. The model calculations showed definite dependence of IOL constants of different formulas on axial length, which was strongest for the SRK II A-constant. Clinical results are in good qualitative and quantitative agreement with SRK/T A-constants varying within 0.4 D for axial length averages of 23.2 to 24.2 mm. Even if the same instrumentation is used, different IOL constants may be necessary due to different axial length means in the respective patient populations. Thus, for best refractive results, constant individualization should be done at the surgeon level. Published constants like ULIB constants are nevertheless a good starting point.
- 1 December 2012
- p. 59-64
Influence of axial length on IOL constants.
In IOL formulas, the lens itself is represented by specific constants. Usually, these are given by the manufacturers as averages that need customization to allow for individual measurement setups. Apart from the instrumentation, patient characteristics such as axial length distribution may influence IOL constants, as demonstrated in this study. The effect of axial length on different IOL constants was studied on model calculations in theoretical ametropic eyes derived from the standard Gullstrand eye as well as in clinical results obtained for different surgical centers within the ULIB project in optical biometry. The model calculations showed definite dependence of IOL constants of different formulas on axial length, which was strongest for the SRK II A-constant. Clinical results are in good qualitative and quantitative agreement with SRK/T A-constants varying within 0.4 D for axial length averages of 23.2 to 24.2 mm. Even if the same instrumentation is used, different IOL constants may be necessary due to different axial length means in the respective patient populations. Thus, for best refractive results, constant individualization should be done at the surgeon level. Published constants like ULIB constants are nevertheless a good starting point.
- 1 December 2012
- p. 65-9
Biometry and intraocular lens calculation in extreme myopia.
Extreme myopia with axial lengths above 30 mm is very rare (approcimately = 1.2%). Not only is there a considerable risk for a posterior staphyloma making biometry even more difficult; problems also exist in different axial length behavior of current intraocular lens (IOL) formulas. Furthermore, around approximately = 31-32 mm, the required lenses change from plus to minus power IOLs. Special problems associated with this transition were examined in this study. A comparison of the thick- and thin-lens approach with allowance for the role of IOL constants was made and exemplified in model calculations based on the Alcon MA60MA lens in the power range from +5 to -5 D. An equation was derived correlating lens geometry with the effective thin-lens position and thus with the respective IOL constant. Since a dramatic change in lens geometry occurs at the transition from plus to minus powers, a corresponding change is obtained in the necessary IOL constants. If no allowance is made for this effect, refractive errors increasing with axial length will be associated with minus-power IOLs. In conclusion, plus- and minus-IOLs need to be characterized by different sets of IOL constants.
- 1 December 2012
- p. 65-9
Biometry and intraocular lens calculation in extreme myopia.
Extreme myopia with axial lengths above 30 mm is very rare (approcimately = 1.2%). Not only is there a considerable risk for a posterior staphyloma making biometry even more difficult; problems also exist in different axial length behavior of current intraocular lens (IOL) formulas. Furthermore, around approximately = 31-32 mm, the required lenses change from plus to minus power IOLs. Special problems associated with this transition were examined in this study. A comparison of the thick- and thin-lens approach with allowance for the role of IOL constants was made and exemplified in model calculations based on the Alcon MA60MA lens in the power range from +5 to -5 D. An equation was derived correlating lens geometry with the effective thin-lens position and thus with the respective IOL constant. Since a dramatic change in lens geometry occurs at the transition from plus to minus powers, a corresponding change is obtained in the necessary IOL constants. If no allowance is made for this effect, refractive errors increasing with axial length will be associated with minus-power IOLs. In conclusion, plus- and minus-IOLs need to be characterized by different sets of IOL constants.
- 1 January 2012
- Published by Touch Medical Media, Ltd. in European Ophthalmic Review
- Vol. 06 (01)
Intraocular Lens Calculation After Refractive Surgery
More and more patients who have had corneo-refractive surgery present for intraocular lens (IOL) implantation. IOL calculation in these patients is still a challenge. After refractive surgery, if eyes are treated as normal eyes, high hyperopic errors can occur in previously myopic eyes and moderate myopic errors in formerly hyperopic eyes. Three main sources for these errors can be identified: the radius measurement error, the keratometer index error and the IOL formula error. The literature presents a confusing variety of procedures and formulas to cope with this situation. An analysis of the available literature reveals the different methods used to address the individual error contributions, the magnitude of which is assessed by model calculations. The most relevant formulas for clinical practice are the no-history procedures, which require no previous patient data. Using these methods to calculate IOL power after refractive surgery makes it possible to obtain clinical outcomes of a similar quality to that for normal eyes.
- 1 January 2012
- Published by Touch Medical Media, Ltd. in European Ophthalmic Review
- Vol. 06 (01)
Intraocular Lens Calculation After Refractive Surgery
More and more patients who have had corneo-refractive surgery present for intraocular lens (IOL) implantation. IOL calculation in these patients is still a challenge. After refractive surgery, if eyes are treated as normal eyes, high hyperopic errors can occur in previously myopic eyes and moderate myopic errors in formerly hyperopic eyes. Three main sources for these errors can be identified: the radius measurement error, the keratometer index error and the IOL formula error. The literature presents a confusing variety of procedures and formulas to cope with this situation. An analysis of the available literature reveals the different methods used to address the individual error contributions, the magnitude of which is assessed by model calculations. The most relevant formulas for clinical practice are the no-history procedures, which require no previous patient data. Using these methods to calculate IOL power after refractive surgery makes it possible to obtain clinical outcomes of a similar quality to that for normal eyes.
- Open Access
- 1 January 2012
- Published by Medknow in Saudi Journal of Ophthalmology
- Vol. 26 (1) , 7-12
Challenges and approaches in modern biometry and IOL calculation
The introduction of new intraocular lenses (IOLs), industry marketing to the public and patient expectations has warranted increased accuracy of IOL power calculations. Toric IOLs, multifocal IOLs, aspheric IOLs, phakic lenses, accommodative lenses, cases of refractive lens exchange and eyes that have undergone previous refractive surgery all require improved clinical measurements and IOL prediction formulas. Hence, measurement techniques and IOL calculation formulas are essential factors that affect the refractive outcome. Measurement with ultrasound has been the historic standard for measurement of ocular parameters for IOL calculation. However the introduction of optical biometry using partial coherence interferometry (PCI) has steadily established itself as the new standard. Additionally, modern optical instruments such as Scheimpflug cameras and optical coherence tomographers are being used to determine corneal power that was normally the purview of manual keratometry and topography. A number of methods are available to determine the IOL power including the empirical, analytical, numerical or combined methods. Ray tracing techniques or paraxial approximation by matrix methods or classical analytical 'IOL formulas' are actively used in for the prediction of IOL power. There is no universal formula for all cases - phakic and pseudophakic cases require different approaches, as do short eyes, long eyes, astigmatic eyes or post-refractive surgery eyes. Invariably, IOLs are characterized by different methods and lens constants, which require individual optimization. This review describes the current methods for biometry and IOL calculation.
- 1 January 2012
- Published by Medknow in Saudi Journal of Ophthalmology
- Vol. 26 (1) , 7-12
Open AccessChallenges and approaches in modern biometry and IOL calculation
The introduction of new intraocular lenses (IOLs), industry marketing to the public and patient expectations has warranted increased accuracy of IOL power calculations. Toric IOLs, multifocal IOLs, aspheric IOLs, phakic lenses, accommodative lenses, cases of refractive lens exchange and eyes that have undergone previous refractive surgery all require improved clinical measurements and IOL prediction formulas. Hence, measurement techniques and IOL calculation formulas are essential factors that affect the refractive outcome. Measurement with ultrasound has been the historic standard for measurement of ocular parameters for IOL calculation. However the introduction of optical biometry using partial coherence interferometry (PCI) has steadily established itself as the new standard. Additionally, modern optical instruments such as Scheimpflug cameras and optical coherence tomographers are being used to determine corneal power that was normally the purview of manual keratometry and topography. A number of methods are available to determine the IOL power including the empirical, analytical, numerical or combined methods. Ray tracing techniques or paraxial approximation by matrix methods or classical analytical 'IOL formulas' are actively used in for the prediction of IOL power. There is no universal formula for all cases - phakic and pseudophakic cases require different approaches, as do short eyes, long eyes, astigmatic eyes or post-refractive surgery eyes. Invariably, IOLs are characterized by different methods and lens constants, which require individual optimization. This review describes the current methods for biometry and IOL calculation.
- 3 June 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (4) , 458-463
IOL calculation using paraxial matrix optics
Matrix methods have a long tradition in paraxial physiological optics. They are especially suited to describe and handle optical systems in a simple and intuitive manner. While these methods are more and more applied to calculate the refractive power(s) of toric intraocular lenses (IOL), they are hardly used in routine IOL power calculations for cataract and refractive surgery, where analytical formulae are commonly utilized. Since these algorithms are also based on paraxial optics, matrix optics can offer rewarding approaches to standard IOL calculation tasks, as will be shown here. Some basic concepts of matrix optics are introduced and the system matrix for the eye is defined, and its application in typical IOL calculation problems is illustrated. Explicit expressions are derived to determine: predicted refraction for a given IOL power; necessary IOL power for a given target refraction; refractive power for a phakic IOL (PIOL); predicted refraction for a thick lens system. Numerical examples with typical clinical values are given for each of these expressions. It is shown that matrix optics can be applied in a straightforward and intuitive way to most problems of modern routine IOL calculation, in thick or thin lens approximation, for aphakic or phakic eyes.
- 3 June 2009
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 29 (4) , 458-463
IOL calculation using paraxial matrix optics
Matrix methods have a long tradition in paraxial physiological optics. They are especially suited to describe and handle optical systems in a simple and intuitive manner. While these methods are more and more applied to calculate the refractive power(s) of toric intraocular lenses (IOL), they are hardly used in routine IOL power calculations for cataract and refractive surgery, where analytical formulae are commonly utilized. Since these algorithms are also based on paraxial optics, matrix optics can offer rewarding approaches to standard IOL calculation tasks, as will be shown here. Some basic concepts of matrix optics are introduced and the system matrix for the eye is defined, and its application in typical IOL calculation problems is illustrated. Explicit expressions are derived to determine: predicted refraction for a given IOL power; necessary IOL power for a given target refraction; refractive power for a phakic IOL (PIOL); predicted refraction for a thick lens system. Numerical examples with typical clinical values are given for each of these expressions. It is shown that matrix optics can be applied in a straightforward and intuitive way to most problems of modern routine IOL calculation, in thick or thin lens approximation, for aphakic or phakic eyes.
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (5) , 906-911
Intraocular lens calculation in extreme myopia
To study from a theoretical viewpoint the effects in cases of extreme myopia of the different axial length (AL) behavior of current intraocular lens (IOL) calculation formulas and the problems caused by changes in lens geometry in the transition from plus to minus lenses. University Eye Hospital, Wuerzburg, Germany. A comparison of the thick-lens and thin-lens approach was made with allowance for the role of IOL constants and exemplified in model calculations based on design data of the MA60MA IOL in the power range from +5.0 to -5.0 diopters. Ray tracing was used to define model eyes for the MA60MA IOL, and the IOL constants producing the correct lens powers with the Haigis formula were determined. An equation was derived linking lens geometry represented by the positions of the principal planes with the effective thin-lens position and thus with the respective IOL constants. Because IOL geometry changes considerably at the transition from plus to minus powers, a corresponding change is obtained in the necessary IOL constants. If no allowance is made for this effect, refractive errors increasing with AL will be associated with minus-power IOLs. Plus IOLs and minus IOLs have to be characterized by different sets of IOL constants.
- 1 May 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (5) , 906-911
Intraocular lens calculation in extreme myopia
To study from a theoretical viewpoint the effects in cases of extreme myopia of the different axial length (AL) behavior of current intraocular lens (IOL) calculation formulas and the problems caused by changes in lens geometry in the transition from plus to minus lenses. University Eye Hospital, Wuerzburg, Germany. A comparison of the thick-lens and thin-lens approach was made with allowance for the role of IOL constants and exemplified in model calculations based on design data of the MA60MA IOL in the power range from +5.0 to -5.0 diopters. Ray tracing was used to define model eyes for the MA60MA IOL, and the IOL constants producing the correct lens powers with the Haigis formula were determined. An equation was derived linking lens geometry represented by the positions of the principal planes with the effective thin-lens position and thus with the respective IOL constants. Because IOL geometry changes considerably at the transition from plus to minus powers, a corresponding change is obtained in the necessary IOL constants. If no allowance is made for this effect, refractive errors increasing with AL will be associated with minus-power IOLs. Plus IOLs and minus IOLs have to be characterized by different sets of IOL constants.
- 1 February 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (2) , 229-233
Matrix-optical Representation of Currently Used Intraocular Lens Power Formulas
Purpose: The formulas presently used to calculate the power of intraocular lenses (IOLs) are the SRK II, SRK/T, Holladay I, Hoffer Q, and Haigis. Apart from the empirical SRK II, these formulas are based on paraxial optics. With different notations and different algebraic forms, a comparison between formulas is difficult. Matrix techniques, on the other hand, have been successfully used in paraxial optics for many years, offering an elegant, simple, and straightforward way to characterize complex optical systems. The aim of this study, therefore, was to represent the current theoretical IOL formulas in matrix notation. Methods: The SRK/T, Holladay I, Hoffer Q, and Haigis formulas were analyzed, algebraically transformed, and expressed in matrix-optical notation in the form of translation and refraction matrices and the system matrix. An example calculation was carried out and compared to results from two commercial biometry instruments (Zeiss IOLMaster and Tomey AL-2000). Results: Although all formulas examined are based on thin lens optics in paraxial approximation, considerable differences exist in the interpretation and calculation of corneal power, axial length, and effective lens position as well as the manner in which individual IOLs are represented (“IOL constants”). All relations necessary for matrix-optical representation are given. Conclusions: The matrix-optical representation of the currently used IOL power formulas offers new insights into the calculation of IOLs and allows a deeper understanding of the advantages and drawbacks of each formula. [ J Refract Surg. 2009;25:229–234.]
- 1 February 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (2) , 229-233
Matrix-optical Representation of Currently Used Intraocular Lens Power Formulas
Purpose: The formulas presently used to calculate the power of intraocular lenses (IOLs) are the SRK II, SRK/T, Holladay I, Hoffer Q, and Haigis. Apart from the empirical SRK II, these formulas are based on paraxial optics. With different notations and different algebraic forms, a comparison between formulas is difficult. Matrix techniques, on the other hand, have been successfully used in paraxial optics for many years, offering an elegant, simple, and straightforward way to characterize complex optical systems. The aim of this study, therefore, was to represent the current theoretical IOL formulas in matrix notation. Methods: The SRK/T, Holladay I, Hoffer Q, and Haigis formulas were analyzed, algebraically transformed, and expressed in matrix-optical notation in the form of translation and refraction matrices and the system matrix. An example calculation was carried out and compared to results from two commercial biometry instruments (Zeiss IOLMaster and Tomey AL-2000). Results: Although all formulas examined are based on thin lens optics in paraxial approximation, considerable differences exist in the interpretation and calculation of corneal power, axial length, and effective lens position as well as the manner in which individual IOLs are represented (“IOL constants”). All relations necessary for matrix-optical representation are given. Conclusions: The matrix-optical representation of the currently used IOL power formulas offers new insights into the calculation of IOLs and allows a deeper understanding of the advantages and drawbacks of each formula. [ J Refract Surg. 2009;25:229–234.]
- 9 November 2008
- Published by Springer Nature in Der Ophthalmologe
- Vol. 105 (11) , 999-1004
IOL-Kalkulation bei hohen Ametropien
Die mit hohen Ametropien verbundenen langen und kurzen Augen stellen für Biometrie und Intraokularlinsen- (IOL-)Berechnung besondere Probleme dar. Wegen ihrer oft veränderten Geometrie sind diese Augen mit Ultraschall häufig schwieriger zu messen als Normalaugen. Dies gilt insbesondere für lange Augen, bei denen die optische Biometrie von deutlichem Vorteil ist. Messfehler, IOL-Fertigungstoleranzen und Unsicherheiten bei der Vorhersage der IOL-Position wirken sich bei kurzen Augen viel stärker aus als bei normalen. Von besonderer Bedeutung für das refraktive Ergebnis ist die Wahl einer geeigneten IOL-Formel. Für kurze Augen sind Holladay-2, HofferQ und Haigis, für lange Augen Holladay-1, Holladay-2 und Haigis geeignet. In jedem Fall müssen optimierte IOL-Konstanten verwendet werden. Werden Minuslinsen bei extrem langen Augen mit denselben Konstanten wie Pluslinsen berechnet, so resultiert ein hyperoper Refraktionsfehler, der durch einen eigenen Konstantensatz für Minuslinsen vermieden werden kann. Bei extrem kurzen Augen versagt die übliche Näherung dünner Linsen, sodass hier auf Dicke-Linsen-Rechnungen oder „raytracing“ zurückgegriffen werden muss. Long and short eyes are connected with high ametropia and constitute special problems for biometry and IOL calculations. Ultrasound measurements on these eyes, which often have altered geometries, are frequently more difficult than in normal eyes. This holds especially for long eyes, which significantly benefit from optical biometry. Measurement errors, IOL manufacturing tolerances and uncertainties regarding the effective lens position affect short eyes much more than normal eyes. The selection of a suitable IOL formula is of special importance for the refractive outcome. For short eyes, Holladay-2, HofferQ and Haigis are recommended, for long eyes Holladay-1, Holladay-2 and Haigis. In each case, optimized IOL constants must be used. If minus lenses for extremely long eyes are calculated with the same constants as plus lenses, a hyperopic refractive error is created, which can be avoided by a separate set of constants for minus lenses. For extremely short eyes the commonly used approximation of thinner lenses fails necessitating a thick lens calculation or raytracing.
- 9 November 2008
- Published by Springer Nature in Der Ophthalmologe
- Vol. 105 (11) , 999-1004
IOL-Kalkulation bei hohen Ametropien
Die mit hohen Ametropien verbundenen langen und kurzen Augen stellen für Biometrie und Intraokularlinsen- (IOL-)Berechnung besondere Probleme dar. Wegen ihrer oft veränderten Geometrie sind diese Augen mit Ultraschall häufig schwieriger zu messen als Normalaugen. Dies gilt insbesondere für lange Augen, bei denen die optische Biometrie von deutlichem Vorteil ist. Messfehler, IOL-Fertigungstoleranzen und Unsicherheiten bei der Vorhersage der IOL-Position wirken sich bei kurzen Augen viel stärker aus als bei normalen. Von besonderer Bedeutung für das refraktive Ergebnis ist die Wahl einer geeigneten IOL-Formel. Für kurze Augen sind Holladay-2, HofferQ und Haigis, für lange Augen Holladay-1, Holladay-2 und Haigis geeignet. In jedem Fall müssen optimierte IOL-Konstanten verwendet werden. Werden Minuslinsen bei extrem langen Augen mit denselben Konstanten wie Pluslinsen berechnet, so resultiert ein hyperoper Refraktionsfehler, der durch einen eigenen Konstantensatz für Minuslinsen vermieden werden kann. Bei extrem kurzen Augen versagt die übliche Näherung dünner Linsen, sodass hier auf Dicke-Linsen-Rechnungen oder „raytracing“ zurückgegriffen werden muss. Long and short eyes are connected with high ametropia and constitute special problems for biometry and IOL calculations. Ultrasound measurements on these eyes, which often have altered geometries, are frequently more difficult than in normal eyes. This holds especially for long eyes, which significantly benefit from optical biometry. Measurement errors, IOL manufacturing tolerances and uncertainties regarding the effective lens position affect short eyes much more than normal eyes. The selection of a suitable IOL formula is of special importance for the refractive outcome. For short eyes, Holladay-2, HofferQ and Haigis are recommended, for long eyes Holladay-1, Holladay-2 and Haigis. In each case, optimized IOL constants must be used. If minus lenses for extremely long eyes are calculated with the same constants as plus lenses, a hyperopic refractive error is created, which can be avoided by a separate set of constants for minus lenses. For extremely short eyes the commonly used approximation of thinner lenses fails necessitating a thick lens calculation or raytracing.
- 1 October 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (10) , 1658-1663
Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula
To describe the Haigis-L formula for the calculation of intraocular lenses (IOLs) after refractive laser surgery for myopia based on current biometry and keratometry and present clinical results. University Eye Hospital, Wuerzburg, Germany, and various clinics and private practices. The basic concepts of the new algorithm were described and summarized. The Haigis formula was analyzed with respect to its usability for eyes after laser surgery for myopia and modified accordingly. Correction curves for IOLMaster keratometry were derived from previous studies. The new formula was checked using the postoperative results of 187 cataract procedures in which 32 IOL types were implanted by 57 surgeons. Input data were current IOLMaster biometry as follows: axial length (AL), anterior chamber depth (ACD), and keratometry (corneal radii) measurements. Before IOL surgery, the mean spherical equivalent was -7.60 diopters (D)+/-3.90 (SD) (range -20.00 to -1.25 D); the mean AL, 27.02+/-2.01 mm (range 23.09 to 35.32 mm); the mean ACD, 3.52 +/- 0.36 mm (range 2.43 to 4.39 mm); and the mean of the measured corneal radii, 8.70+/-0.60 mm (range 7.28 to 10.96 mm). The mean arithmetic refractive prediction error was -0.04+/-0.70 D (range -2.30 to +2.40 D) and the median absolute error, 0.37 D (range +0.01 to +2.40 D). The percentages of correct refraction predictions within +/-2.00, +/-1.00, and +/-0.50 D were 98.4%, 84.0%, and 61.0%, respectively. The new formula would produce promising results in eyes without refractive history. Its refractive predictability fulfills the current criteria for normal eyes.
- 1 October 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (10) , 1658-1663
Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula
To describe the Haigis-L formula for the calculation of intraocular lenses (IOLs) after refractive laser surgery for myopia based on current biometry and keratometry and present clinical results. University Eye Hospital, Wuerzburg, Germany, and various clinics and private practices. The basic concepts of the new algorithm were described and summarized. The Haigis formula was analyzed with respect to its usability for eyes after laser surgery for myopia and modified accordingly. Correction curves for IOLMaster keratometry were derived from previous studies. The new formula was checked using the postoperative results of 187 cataract procedures in which 32 IOL types were implanted by 57 surgeons. Input data were current IOLMaster biometry as follows: axial length (AL), anterior chamber depth (ACD), and keratometry (corneal radii) measurements. Before IOL surgery, the mean spherical equivalent was -7.60 diopters (D)+/-3.90 (SD) (range -20.00 to -1.25 D); the mean AL, 27.02+/-2.01 mm (range 23.09 to 35.32 mm); the mean ACD, 3.52 +/- 0.36 mm (range 2.43 to 4.39 mm); and the mean of the measured corneal radii, 8.70+/-0.60 mm (range 7.28 to 10.96 mm). The mean arithmetic refractive prediction error was -0.04+/-0.70 D (range -2.30 to +2.40 D) and the median absolute error, 0.37 D (range +0.01 to +2.40 D). The percentages of correct refraction predictions within +/-2.00, +/-1.00, and +/-0.50 D were 98.4%, 84.0%, and 61.0%, respectively. The new formula would produce promising results in eyes without refractive history. Its refractive predictability fulfills the current criteria for normal eyes.
- 15 March 2007
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 17 (1) , 45-54
Präoperative Berechnung der Stärke intraokularer Linsen bei Problemaugen
- 15 March 2007
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 17 (1) , 45-54
Präoperative Berechnung der Stärke intraokularer Linsen bei Problemaugen