Yu-Kang Lo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu-Kang Lo has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Huang-Jen Chiu
National Taiwan University of Science and Technology, Taipei, Taiwan
7 shared publications Jing‐Yuan Lin
Department of Electronic Engineering National Taiwan University of Science and Technology No. 43, Sec.4, Keelung Rd. Taipei 10607 Taiwan R.O.C.
6 shared publicationsChung‐Yi Lin
Department of Electronic Engineering National Taiwan University of Science and Technology Taipei 10607 Taiwan R.O.C.
4 shared publicationsHuang‐Jen Chiu
Department of Electronic Engineering National Taiwan University of Science and Technology Taipei 10607 Taiwan R.O.C.
4 shared publications- Hung-Chun Chien
Department of Electronic Engineering, Ming Chuan University, No. 5, Deming Road, Guishan District, Taoyuan City 333, Taiwan
4 shared publications Shih-Jen Cheng
3 shared publications
Latest Publications
- 21 October 2015
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 39 (2) , 1-10
Systematic analysis and design of dual-switch Flyback converter
This paper presents the circuit analysis and design considerations for the dual-switch Flyback converter. The operation modes are individually analyzed and the corresponding state equations are presented accordingly. Also, the design equations for key components are derived. Good agreement can be obtained among the Pspice simulation, the experimental results and the theoretical analysis. The analytic equations are valid not only for full load and continuous conduction-mode condition, but also for critical-mode operation, which meets the design specifications.
- 21 October 2015
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 39 (2) , 1-10
Systematic analysis and design of dual-switch Flyback converter
This paper presents the circuit analysis and design considerations for the dual-switch Flyback converter. The operation modes are individually analyzed and the corresponding state equations are presented accordingly. Also, the design equations for key components are derived. Good agreement can be obtained among the Pspice simulation, the experimental results and the theoretical analysis. The analytic equations are valid not only for full load and continuous conduction-mode condition, but also for critical-mode operation, which meets the design specifications.
- 5 August 2015
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 38 (8) , 1-13
A cascode-circuit configuration for grid-tied solar micro-inverters
This study proposes a solar micro-inverter that is connected to the AC grid through a cascode circuit configuration. Low system complexity and high circuit efficiency can be achieved through the concept of single-stage power conversion. A laboratory prototype is designed and implemented with DSP control to realize the maximum power point tracking function. The operating principles and design-related considerations of the proposed cascode micro-inverter are discussed in detail. The simulation and experimental results for the prototype circuit are shown to verify the feasibility of the proposed configuration.
- 5 August 2015
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 38 (8) , 1-13
A cascode-circuit configuration for grid-tied solar micro-inverters
This study proposes a solar micro-inverter that is connected to the AC grid through a cascode circuit configuration. Low system complexity and high circuit efficiency can be achieved through the concept of single-stage power conversion. A laboratory prototype is designed and implemented with DSP control to realize the maximum power point tracking function. The operating principles and design-related considerations of the proposed cascode micro-inverter are discussed in detail. The simulation and experimental results for the prototype circuit are shown to verify the feasibility of the proposed configuration.
- 8 September 2012
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 42 (2) , 111-126
Analysis and design of a two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter
SUMMARY: This paper presents a two‐transformer active‐clamping zero‐voltage‐switching (ZVS) isolated inverse‐SEPIC converter, which is mainly composed of two active‐clamping ZVS isolated inverse‐SEPIC converters. The proposed converter allows a low‐profile design for liquid crystal display TVs and servers. The presented two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter can equally share the total load current between two secondaries. Therefore, the output inductor copper loss and the output diode conduction loss can be decreased. Detailed analysis and design of this new two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter are described. Experimental results are recorded for a prototype converter with an AC input voltage ranging from 85 to 135 V, an output voltage of 12 V and a rated output current of 13.5A, operating at a switching frequency of 65 kHz. Copyright © 2012 John Wiley & Sons, Ltd.
- 8 September 2012
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 42 (2) , 111-126
Analysis and design of a two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter
SUMMARY: This paper presents a two‐transformer active‐clamping zero‐voltage‐switching (ZVS) isolated inverse‐SEPIC converter, which is mainly composed of two active‐clamping ZVS isolated inverse‐SEPIC converters. The proposed converter allows a low‐profile design for liquid crystal display TVs and servers. The presented two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter can equally share the total load current between two secondaries. Therefore, the output inductor copper loss and the output diode conduction loss can be decreased. Detailed analysis and design of this new two‐transformer active‐clamping ZVS isolated inverse‐SEPIC converter are described. Experimental results are recorded for a prototype converter with an AC input voltage ranging from 85 to 135 V, an output voltage of 12 V and a rated output current of 13.5A, operating at a switching frequency of 65 kHz. Copyright © 2012 John Wiley & Sons, Ltd.
- 18 January 2012
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 41 (7) , 772-778
Analysis and design of a dual‐mode control flyback converter
SUMMARY: This letter presents a dual‐mode control scheme to improve the efficiency of a flyback converter in a wide load range. The proposed flyback converter features a novel dual‐mode operation. The valley‐switching technique is adopted to reduce the switching loss at light load. On the other hand, the fixed off‐time (FOT) controls with continuous conduction mode operations decrease the conduction losses at heavy load. The principles and design procedures of the proposed dual‐mode controller are discussed and analyzed. Finally, a 140‐W dual‐mode flyback converter with an output voltage of 19 V is implemented. Experimental results agree with the theoretical analysis. Copyright © 2012 John Wiley & Sons, Ltd.
- 18 January 2012
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 41 (7) , 772-778
Analysis and design of a dual‐mode control flyback converter
SUMMARY: This letter presents a dual‐mode control scheme to improve the efficiency of a flyback converter in a wide load range. The proposed flyback converter features a novel dual‐mode operation. The valley‐switching technique is adopted to reduce the switching loss at light load. On the other hand, the fixed off‐time (FOT) controls with continuous conduction mode operations decrease the conduction losses at heavy load. The principles and design procedures of the proposed dual‐mode controller are discussed and analyzed. Finally, a 140‐W dual‐mode flyback converter with an output voltage of 19 V is implemented. Experimental results agree with the theoretical analysis. Copyright © 2012 John Wiley & Sons, Ltd.
- 13 December 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (12) , 1199-1213
Design of a two‐output forward converter with an output voltage objective function
A new method is proposed in this paper to distribute the steady‐state output voltage errors in a two‐output forward converter. The cross regulation between the two output voltages are described in terms of the circuit parameters. An objective function is formed for each of the two outputs to track its reference within the specified error. The legitimate duty cycle range is located through the transfer characteristics between the duty cycle and the load currents. The weighting feedback gains of the two output voltages can be determined by the presented control scheme which optimizes the objective function. The proposed method is suitable for a two‐output system without a dominant load. Experiments on a prototype are conducted to show that there exist a duty cycle range and a set of weighted feedback gains minimizing the defined objective function. Copyright © 2010 John Wiley & Sons, Ltd.
- 13 December 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (12) , 1199-1213
Design of a two‐output forward converter with an output voltage objective function
A new method is proposed in this paper to distribute the steady‐state output voltage errors in a two‐output forward converter. The cross regulation between the two output voltages are described in terms of the circuit parameters. An objective function is formed for each of the two outputs to track its reference within the specified error. The legitimate duty cycle range is located through the transfer characteristics between the duty cycle and the load currents. The weighting feedback gains of the two output voltages can be determined by the presented control scheme which optimizes the objective function. The proposed method is suitable for a two‐output system without a dominant load. Experiments on a prototype are conducted to show that there exist a duty cycle range and a set of weighted feedback gains minimizing the defined objective function. Copyright © 2010 John Wiley & Sons, Ltd.
- 3 November 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 41 (4) , 410-423
Analysis and design of a push–pull DCM boost power factor corrector
SUMMARY: A novel power factor corrector (PFC) composed of two‐phase discontinuous conduction mode (DCM) boost PFCs and a coupled inductor is proposed in this paper. By coupling the two‐phase boost inductors into the same magnetic core, both the circuit volume and the input ripple current are reduced. Therefore, the power factor (PF) value and the power density are improved. In addition, the output capacitor size can be smaller. The proposed topology distributes the input current and output current equally for the two phase modules. A cut‐in‐half duty cycle can decrease the conduction losses of the switches, and both the turns and diameters of the inductor windings, which help more in the reduction of the circuit volume. The advantages of a DCM boost PFC, such as natural zero‐current‐switching (ZCS) of the output diode, a natural PFC function and the simplified EMI filter design, are maintained. Detailed analysis and design of the proposed topology and the experimental results on a prototype with a 380‐V output voltage and a 200‐W output power are provided. Copyright © 2011 John Wiley & Sons, Ltd.
- 3 November 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 41 (4) , 410-423
Analysis and design of a push–pull DCM boost power factor corrector
SUMMARY: A novel power factor corrector (PFC) composed of two‐phase discontinuous conduction mode (DCM) boost PFCs and a coupled inductor is proposed in this paper. By coupling the two‐phase boost inductors into the same magnetic core, both the circuit volume and the input ripple current are reduced. Therefore, the power factor (PF) value and the power density are improved. In addition, the output capacitor size can be smaller. The proposed topology distributes the input current and output current equally for the two phase modules. A cut‐in‐half duty cycle can decrease the conduction losses of the switches, and both the turns and diameters of the inductor windings, which help more in the reduction of the circuit volume. The advantages of a DCM boost PFC, such as natural zero‐current‐switching (ZCS) of the output diode, a natural PFC function and the simplified EMI filter design, are maintained. Detailed analysis and design of the proposed topology and the experimental results on a prototype with a 380‐V output voltage and a 200‐W output power are provided. Copyright © 2011 John Wiley & Sons, Ltd.
- 11 May 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (5) , 501-514
Analysis and design of a two‐transformer active‐clamping forward converter with parallel‐connected current doubler rectifiers
A new two‐transformer active‐clamping forward converter with parallel‐connected current doubler rectifiers (CDRs) is proposed in this paper. The presented DC–DC converter is mainly composed of two active‐clamping forward converters with secondary CDRs. Only two switches are required and each one is the auxiliary switch for the other. The circuit complexity and cost are thus reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve zero‐voltage‐switching (ZVS) during the dead times. Two CDRs at the secondary side are connected in parallel to reduce the current stresses of the secondary windings and the ripple current at the output side. Accordingly, the smaller output chokes and capacitors decrease the converter volume and increase the power density. Detailed analysis and design of the presented two‐transformer active‐clamping forward converter are described. Experimental results are recorded for a prototype converter with a DC input voltage of 130−−180V, an output voltage of 5 V and an output current of 40 A, operating at a switching frequency of 100 kHz. Copyright © 2010 John Wiley & Sons, Ltd.
- 11 May 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (5) , 501-514
Analysis and design of a two‐transformer active‐clamping forward converter with parallel‐connected current doubler rectifiers
A new two‐transformer active‐clamping forward converter with parallel‐connected current doubler rectifiers (CDRs) is proposed in this paper. The presented DC–DC converter is mainly composed of two active‐clamping forward converters with secondary CDRs. Only two switches are required and each one is the auxiliary switch for the other. The circuit complexity and cost are thus reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve zero‐voltage‐switching (ZVS) during the dead times. Two CDRs at the secondary side are connected in parallel to reduce the current stresses of the secondary windings and the ripple current at the output side. Accordingly, the smaller output chokes and capacitors decrease the converter volume and increase the power density. Detailed analysis and design of the presented two‐transformer active‐clamping forward converter are described. Experimental results are recorded for a prototype converter with a DC input voltage of 130−−180V, an output voltage of 5 V and an output current of 40 A, operating at a switching frequency of 100 kHz. Copyright © 2010 John Wiley & Sons, Ltd.
- 11 May 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (5) , 533-542
A high‐input‐voltage backlight module driver for multi‐lamp LCD panels
A half‐bridge (HB) resonant inverter for driving a backlight module with multiple cold cathode fluorescent lamps (CCFLs) is proposed. Conventionally, a backlight module driving inverter is designed to operate with a low‐input DC voltage. Therefore, a buck converter is required to step down the high‐output DC voltage of a power factor correction (PFC) pre‐regulator. The circuit cost is high and the conversion efficiency is low. In this letter, a high‐input‐voltage HB resonant inverter with only one transformer is used to drive multiple lamps. Analysis and design considerations are discussed in detail. Simulations and experimental results are close to the theoretical prediction. Copyright © 2010 John Wiley & Sons, Ltd.
- 11 May 2011
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 39 (5) , 533-542
A high‐input‐voltage backlight module driver for multi‐lamp LCD panels
A half‐bridge (HB) resonant inverter for driving a backlight module with multiple cold cathode fluorescent lamps (CCFLs) is proposed. Conventionally, a backlight module driving inverter is designed to operate with a low‐input DC voltage. Therefore, a buck converter is required to step down the high‐output DC voltage of a power factor correction (PFC) pre‐regulator. The circuit cost is high and the conversion efficiency is low. In this letter, a high‐input‐voltage HB resonant inverter with only one transformer is used to drive multiple lamps. Analysis and design considerations are discussed in detail. Simulations and experimental results are close to the theoretical prediction. Copyright © 2010 John Wiley & Sons, Ltd.