ZSZdenka Stojanovska

Zdenka Stojanovska

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zdenka Stojanovska has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Blazo Boev

    Faculty of Natural and Technical Sciences, Goce Delcev University, Krste Misirkov No.10-A, P. O. 201, 2000, Stip, Republic of Macedonia

    2 shared publications
  • Carmela Carpentieri

    Italian National Institute of Health, Rome, Italy

    2 shared publications
  • Mimoza Ristova

    Faculty of Natural Sciences and Mathematic, Institute of Physics, University in Ss. Cyril and Methodius, Arhimedova 3, 1000, Skopje, Republic of Macedonia

    2 shared publications
  • Peter Bossew

    German Federal Office for Radiation Protection, div. SW 1.1, 120-130 Köpenicker Allee, 10318, Berlin, Germany

    2 shared publications
  • Zora S. Zunic

    Institute of Nuclear Sciences "Vinča", University of Belgrade, P. O. Box 522, Belgrade, 11000, Serbia

    2 shared publications
  • A. Cuco -Dinu

    Environmental Radioactivity and Nuclear Dating Center, Babeş-Bolyai University, Cluj-Napoca, Romania

    1 shared publication

Latest Publications

  • The relation between radon in schools and in dwellings: A case study in a rural region of Southern Serbia

    by Z.S. Žunić, P. Bossew, F. Bochicchio, N. Veselinovic, C. Carpentieri, G. Venoso, S. Antignani, R. Simovic, Z. Ćurguz, V. Udovicic, et al.


  • Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    by Zdenka Stojanovska, Blazo Boev, Zora S. Zunic, Kremena Ivanova, Mimoza Ristova, Martina Tsenova, Sorsa Ajka, Emilija Janevik, Vaso Taleski, Peter Bossew

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m3 for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.


  • Results from time integrated measurements of indoor radon, thoron and their decay product concentrations in schools in the Republic of Macedonia

    by Zdenka Stojanovska, Zora S. Zunic, Peter Bossew, Francesco Bochicchio, Carmela Carpentieri, Gennaro Venoso, Rosaline Mishra, R. P. Rout, B. K. Sapra, Bety D. Burghele, et al.

    As part of a survey on concentrations of radon, thoron and their decay products in different indoor environments of the Balkan region involving international collaboration, measurements were performed in 43 schools from 5 municipalities of the Republic of Macedonia. The time-integrated radon and thoron gas concentrations (CRn and CTn) were measured by CR-39 (placed in chambers with different diffusion barriers), whereas the equilibrium equivalent radon and thoron concentrations (EERC and EETC) were measured using direct radon–thoron progeny sensors consisting of LR-115 nuclear track detectors. The detectors were deployed at a distance of at least 0.5 m from the walls as well as far away from the windows and doors in order to obtain more representative samples of air from the breathing zone; detectors were exposed over a 3-month period (March–May 2012). The geometric mean (GM) values [and geometric standard deviations (GSDs)] of CRn, CTn, EERC and EETC were 76 (1.7), 12 (2.3), 27 (1.4) and 0.75 Bq m−3 (2.5), respectively. The equilibrium factors between radon and its decay products (FRn) and thoron and its decay products (FTn>0.5 m) were evaluated: FRn ranged between 0.10 and 0.84 and FTn>0.5 m ranged between 0.003 and 0.998 with GMs (and GSDs) equal to 0.36 (1.7) and 0.07 (3.4), respectively.


  • Indoor exposure of population to radon in the FYR of Macedonia

    by Zdenka Stojanovska, Jovan Januseski, Blazo Boev, Mimoza Ristova

    The authors present the results of a year-long survey of the indoor radon concentration levels in the FYR of Macedonia. A total number of 437 dwellings in eight statistical regions were subject to radon concentration measurements by using CR-39 track detectors. The annual mean indoor radon concentration in each measuring site was estimated from the four individual measurements with 3 months duration. The measuring period was from December 2008 to December 2009. The distribution of the results was nearly log–normal. The arithmetic and geometric mean values of the annual mean value of radon concentration were estimated to be 105±84 and 84*/1.9 Bq m−3, respectively. The annual effective dose due to indoor exposure to radon in the dwellings was estimated to be 2.1*/1.9 mSv y−1.