AKAbdul Khaliq

Abdul Khaliq

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdul Khaliq has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • R. Kumar

    Madhav Inst Technol & Sci Gwalior, Gwalior 474005, India

    3 shared publications
  • I. Dincer

    Faculty of Engineering and Applied Science, University of Ontario Institute of Technology, 2000 Simcoe Street, North Oshawa, ON, LIH 7K4, Canada

    2 shared publications
  • K. Choudhary

    Mechanical Engineering DepartmentO P Jindal Institute of Technology, Raigarh 496 001, India

    2 shared publications
  • R Kumar

    Madhav Institute of Technology and Science Gwalior 474005, India

    1 shared publication
  • Rajesh Kumar

    Mechanical and Automation Engineering Department, Amity School of Engineering and Technology, GGSIPU, New Delhi 110 061, India

    1 shared publication

Latest Publications

  • Exergy analysis of industrial waste heat recovery based ejector vapour compression refrigeration system

    by R. Kumar, R Kumar, A Khaliq

    This communication employed a thermodynamic analysis through energy and exergy for the performance evaluation of waste heat recovery based ejector compression refrigeration in which internal heat exchanger and cooler are used to enhance the performance of the cycle. The system is an integration of the Rankine power cycle and the compression refrigeration cycle. A comprehensive parametric study is performed to investigate the effects of exhaust gas inlet temperature, pinch point (PP) and evaporator temperature on the energetic and exergetic coefficient of performance (COP) of the system as well on the exergy destruction in each component. It is shown that the exergetic COP of the system decreases significantly with the increase in exhaust gas temperature and PP, while the energetic COP increases slightly. The effect of evaporator temperature also shows a similar behaviour. It is further shown that the exergetic coefficient of performance of the system is ∼75% lower than the COP of the same system. It was also observed that the exergy destruction in the heat recovery steam generator increases with the increase in exhaust gas temperature and PP. Exergy analysis indicates that maximum exergy is destroyed during steam generation and condensation process, i.e. ∼65% of the total exergy destruction in the system. The least exergy destruction was found in the separator of 0·3%. The present analysis contributes further information on the role of exhaust gas temperature, PP of heat recovery steam generator and evaporator temperature on the performance of waste heat recovery based compression refrigeration from the exergy point of view.


  • Exergy analysis of the regenerative gas turbine cycle using absorption inlet cooling and evaporative aftercooling

    by A. Khaliq, K. Choudhary

    This paper provides an exergy analysis to investigate the effects of pressure ratio, turbine inlet temperature, compressor inlet temperature and ambient relative humidity on the thermodynamic performance of a regenerative gas turbine cycle using absorption inlet cooling and evaporative aftercooling. Combined first and second law analysis indicates that the exergy destruction in various components of the gas turbine cycle is significantly affected by compressor pressure ratio and turbine inlet temperature, and slightly varies with the compressor inlet temperature and ambient relative humidity. It also indicates that the maximum exergy destroyed in the combustion chamber; which represents over 60% of the total exergy destruction in the overall system. The net work output, first law efficiency, and second law efficiency of the cycle significantly varies with the change in the pressure ratio, turbine inlet temperature, compressor inlet temperature and ambient relative humidity.


  • Exergy Analysis of an Industrial Waste Heat Recovery Based Cogeneration Cycle for Combined Production of Power and Refrigeration

    by A. Khaliq, R. Kumar, I. Dincer

    In this paper, a novel industrial waste heat recovery based cogeneration is proposed for the combined production of power and refrigeration. The system is an integration of Rankine power cycle and absorption refrigeration cycle. A thermodynamic analysis through energy and exergy is employed, and a comprehensive parametric study is performed to investigate the effects of exhaust gas inlet temperature, pinch-point, and gas composition on energy efficiency, power-to-cold ratio, and exergy efficiency of the cogeneration cycle and exergy destruction in each component. The variation in specific heat with exhaust gas composition and temperature is accounted in the analysis for further discussion. The first-law efficiency decreases while power-to-cold ratio and exergy efficiency increase with increasing exhaust gas inlet temperature. The parameters, such as power-to-cold ratio and second-law efficiency, decrease while first-law efficiency increases with increasing pinch-point. Exergy efficiency significantly varies with gas composition and oxygen content of the exhaust gas. Approximating the exhaust gas as air, and the air standard analysis leads to either underestimation or overestimation of cogeneration cycle performance on exergy point of view. Exergy analysis indicates that maximum exergy is destroyed during the steam generation process; which represents around 40% of the total exergy destruction in the overall system. The exergy destruction in each component of the system varies significantly with exhaust gas inlet temperature and pinch-point. The present analysis contributes further information on the role of composition, exhaust gas temperature, and pinch-point influence on the performance of a waste heat recovery based cogeneration system from an exergy point of view.


  • Performance analysis of an industrial waste heat-based trigeneration system

    by A. Khaliq, R. Kumar, I. Dincer

    The thermodynamic performance of an industrial waste heat recovery‐based trigeneration system is studied through energy and exergy efficiency parameters. The effects of exhaust gas inlet temperature, process heat pressure, and ambient temperature on both energy and exergy efficiencies, and electrical to thermal energy ratio of the system are investigated. The energy efficiency increases while electrical to thermal energy ratio and exergy efficiency decrease with increasing exhaust gas inlet temperature. On the other hand, with the increase in process heat pressure, energy efficiency decreases but exergy efficiency and electrical to thermal energy ratio increase. The effect of ambient temperature is also observed due to the fact that with an increase in ambient temperature, energy and exergy efficiencies, and electrical to thermal energy ratio decrease slightly. These results clearly show that performance evaluation of trigeneration system based on energy analysis is not adequate and hence more meaningful evaluation must include exergy analysis. The present analysis contributes to further information on the role of exhaust gas inlet temperature, process heat pressure, ambient temperature influence on the performance of waste heat recovery‐based trigeneration from a thermodynamic point of view. Copyright © 2009 John Wiley & Sons, Ltd.


  • Exergy analysis of double effect vapor absorption refrigeration system

    by Abdul Khaliq, Rajesh Kumar

    Energy and exergy analyses previously performed by the authors for a single effect absorption refrigeration system have been extended to double effect vapor absorption refrigeration system with the expectation of reducing energy supply as well as an interest in the diversification of the motive power employed by HVAC technologies. The total exergy destruction in the system as a percentage of the exergy input from a generator heating water over a range of operating temperatures is examined for a system operating on LiBr–H2O solution. The exergy destruction in each component, the coefficient of performance (COP) and the exergetic COP of the system are determined. It is shown that exergy destructions occur significantly in generators, absorbers, evaporator2 and heat exchangers while the exergy destructions in condenser1, evaporator1, throttling valves, and expansion valves are relatively smaller within the range of 1–5%. The results further indicate that with an increase in the generator1 temperature the COP and ECOP increase, but there is a significant reduction in total exergy destruction of the system for the same. On the other hand, the COP and ECOP decrease with an increase in the absorber1 temperature while the total exergy destruction of the system increases significantly with a small increase in the absorber1 temperature. The results show that the exergy method can be used as an effective criterion in designing an irreversible double effect absorption refrigeration system and may be a good tool for the determination of the optimum working conditions of such systems. Copyright © 2007 John Wiley & Sons, Ltd.


  • Finite-Thermal Reservoir Effects on Ecologically Optimized Closed Regenerative Joule-Brayton Power Cycles

    by A Khaliq

    A finite-time thermodynamic analysis based on a new kind of optimization criterion has been carried out for an endoreversible and regenerative Joule-Brayton power cycle coupled with variable temperature thermal reservoirs. The optimal performance and design parameters that maximize the ecological function are investigated. In this context, the optimal temperatures of the working fluid, the optimum power output, the optimum thermal efficiency, and the optimum second-law efficiency are determined in terms of technical parameters. Results are reported for the effect of regeneration, hot-cold temperature ratio, and the number of heat transfer units in hot and cold exchangers on the optimal performance parameters. The power and efficiency at maximum ecological function are found to be less than the maximum power and Curzon-Ahlborn efficiency. Power output increases significantly with increasing hot-cold side temperature ratio. However, it slightly increased as the number of heat transfer units in the regenerator increases. The optimization of ecological function leads to the improvement in exergetic efficiency and thermal efficiency, especially for low hot-cold side temperature ratios. Moreover, the thermal efficiency at maximum ecological function is less than the average of the finite time or maximum power efficiency and reversible Carnot efficiency.