Sead Berberovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sead Berberovic has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Z. Haznadar
University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000 Zagreb, Croatia
3 shared publicationsFranjo Kelemen
Končar Power Transformers Ltd., a Joint Venture of Siemens AG and Končar d.d., Josipa Mokrovića 6, HR-10090 Zagreb, Croatia
2 shared publicationsHalid Matoruga
2 shared publicationsLeonardo Strac
Končar Power Transformers Ltd., a Joint Venture of Siemens AG and Končar d.d., Josipa Mokrovića 6, HR-10090 Zagreb, Croatia
2 shared publications- Mirza Batalovic
University of Sarajevo,Faculty of Electrical Engineering,Herzegovina,Bosna and Herzegovina
2 shared publications Mirza Matoruga
2 shared publications
Latest Publications
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Electric field and Temperature Distribution along the Polymer Rod Type Suspension Insulator in Polluted Environment
This paper presents a study of the electric field and temperature distribution along the surface of the polymer insulator operating in polluted environment. The study was carried out through the simulations for clean and non-uniformly contaminated insulator surface using finite element tool Comsol Multiphysics software. It has been shown, through the simulation results, that the pollution conductivity significantly affects the heat and electric field propagation along the insulator surface. Area of the insulator surface with lower conductivity value, experiences higher temperatures along with higher electrical field stresses. This indicates that the regions with lower conductivity value become critically over stressed and they contribute to a non-uniform drying process leading to a formation of dry band areas with possible flashover as an epilogue. The main goal is to point out those critical regions resulting as a consequence from different value of the electrical conductivity of the pollution layer.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Electric field and Temperature Distribution along the Polymer Rod Type Suspension Insulator in Polluted Environment
This paper presents a study of the electric field and temperature distribution along the surface of the polymer insulator operating in polluted environment. The study was carried out through the simulations for clean and non-uniformly contaminated insulator surface using finite element tool Comsol Multiphysics software. It has been shown, through the simulation results, that the pollution conductivity significantly affects the heat and electric field propagation along the insulator surface. Area of the insulator surface with lower conductivity value, experiences higher temperatures along with higher electrical field stresses. This indicates that the regions with lower conductivity value become critically over stressed and they contribute to a non-uniform drying process leading to a formation of dry band areas with possible flashover as an epilogue. The main goal is to point out those critical regions resulting as a consequence from different value of the electrical conductivity of the pollution layer.
- 1 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Influence of a delta-connected winding on magnetizing currents of a five-limb core power transformer
Power transformers in their normal lifetime span often encounter unbalanced loads or even DC bias currents that shift the normal operational point of the unit. The influence of a delta connected winding on the magnetizing current waveform of a power transformer will be presented here in more detail. The behavior of an active part is modeled using the system of nonlinear equations solved iteratively, and the results are compared to the ones obtained using three-dimensional nonlinear transient finite element method (FEM).
- 1 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Influence of a delta-connected winding on magnetizing currents of a five-limb core power transformer
Power transformers in their normal lifetime span often encounter unbalanced loads or even DC bias currents that shift the normal operational point of the unit. The influence of a delta connected winding on the magnetizing current waveform of a power transformer will be presented here in more detail. The behavior of an active part is modeled using the system of nonlinear equations solved iteratively, and the results are compared to the ones obtained using three-dimensional nonlinear transient finite element method (FEM).
- 30 April 2009
- Published by Cultech Publishing Sdn. Bhd. in Renewable Energy and Power Quality Journal
- Vol. 7 (1)
Two-speed Synchronous Generator for Special Purposes
This paper deals with basic performances of a design of a two-pole three-phase 40MVA synchronous generator. The generator is designed to test three-phase and single-phase high power transformers aimed to work within 50 Hz and 60 Hz network frequency. This means that the generator will operate at two nominal speeds, at 3000 rpm and 3600 rpm, with nominal power of 40 Mvar induction load when rating with symmetrical three-phase load. The additional requirements relate to constant operation with two-phase 25 MVA load and single-phase 13.5 MVA load, since for testing single-phase and special transformers phase connection you like will be used. In the course of designing, special attention was paid to correct dimensioning of the damper rotor winding as well as to the geometry of stator windings, rotor and air gap, which in the end will produce minimum voltage wave distortion, i.e. generator voltage wave shape with harmonious content less than 1% (as it was demanded).
- 30 April 2009
- Published by Cultech Publishing Sdn. Bhd. in Renewable Energy and Power Quality Journal
- Vol. 7 (1)
Two-speed Synchronous Generator for Special Purposes
This paper deals with basic performances of a design of a two-pole three-phase 40MVA synchronous generator. The generator is designed to test three-phase and single-phase high power transformers aimed to work within 50 Hz and 60 Hz network frequency. This means that the generator will operate at two nominal speeds, at 3000 rpm and 3600 rpm, with nominal power of 40 Mvar induction load when rating with symmetrical three-phase load. The additional requirements relate to constant operation with two-phase 25 MVA load and single-phase 13.5 MVA load, since for testing single-phase and special transformers phase connection you like will be used. In the course of designing, special attention was paid to correct dimensioning of the damper rotor winding as well as to the geometry of stator windings, rotor and air gap, which in the end will produce minimum voltage wave distortion, i.e. generator voltage wave shape with harmonious content less than 1% (as it was demanded).
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Estimation of Stray Losses Outside of Windings in Power Transformers Using Three Dimensional Static Magnetic Field Solution and Statistics
Stray losses outside of windings are a subject of numerous different analyses in the power transformer production industry. The purpose of this paper is to illustrate an approach that combines 3D finite element static magnetic field calculation and nonlinear mathematical programming in a single method derived to increase accuracy of stray losses estimation.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Estimation of Stray Losses Outside of Windings in Power Transformers Using Three Dimensional Static Magnetic Field Solution and Statistics
Stray losses outside of windings are a subject of numerous different analyses in the power transformer production industry. The purpose of this paper is to illustrate an approach that combines 3D finite element static magnetic field calculation and nonlinear mathematical programming in a single method derived to increase accuracy of stray losses estimation.
- 7 September 2007
- Published by Wiley in European Transactions on Electrical Power
- Vol. 10 (2) , 105-111
Correction of resistance measurement of large grounding systems
- 7 September 2007
- Published by Wiley in European Transactions on Electrical Power
- Vol. 10 (2) , 105-111
Correction of resistance measurement of large grounding systems
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1003-1007
Turbogenerator refurbishment with up-rating based on embedding stator damper winding and modern electromagnetic materials
40 MVA two-pole air cooled turbogenerator has been up-graded with stator refurbishment only. Generator active power has been increased from 32 MW to 42 MW with reference to 31% and apparent power has been increased for 23.5%, from 40 MVA to 49.4 MVA. It was necessary to redesign stator core and winding, to embed the stator damper winding and implement new magnetic and insulating materials in order to reach new higher power. Redesigned stator core needs to be of the same outside dimensions as the original one, and to be placed in the old stator casing. Refurbishment requirements with remaining the original machine parameters (but higher output) such as synchronous reactance, audible noise level, voltage and frequency regulation, reactive power and temperature rise in insulation class B have been achieved. Impact of embedding the stator damper winding has been determined by finite-element analysis since the other parameters of refurbished generator have been calculated using analytical and finite element modeling.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1003-1007
Turbogenerator refurbishment with up-rating based on embedding stator damper winding and modern electromagnetic materials
40 MVA two-pole air cooled turbogenerator has been up-graded with stator refurbishment only. Generator active power has been increased from 32 MW to 42 MW with reference to 31% and apparent power has been increased for 23.5%, from 40 MVA to 49.4 MVA. It was necessary to redesign stator core and winding, to embed the stator damper winding and implement new magnetic and insulating materials in order to reach new higher power. Redesigned stator core needs to be of the same outside dimensions as the original one, and to be placed in the old stator casing. Refurbishment requirements with remaining the original machine parameters (but higher output) such as synchronous reactance, audible noise level, voltage and frequency regulation, reactive power and temperature rise in insulation class B have been achieved. Impact of embedding the stator damper winding has been determined by finite-element analysis since the other parameters of refurbished generator have been calculated using analytical and finite element modeling.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1467-1472
Modeling of ship's shaft generator
Shaft generators, which are inserted in the shafting between the main propulsion engine and propeller, are important source of power on ships. Detailed knowledge of electromagnetic characteristics of shaft generator is necessary for design complex ship's power system. Such knowledge is obtainable only by numerical simulations. In this paper we simulate no-load and rated load electromagnetic state in low-speed ship's generator and present methodology for calculation of reactances from field solutions. Another important problem in design of shaft generator is dimensioning of cooling system because of limited space for the generator. Therefore, we present results of numerical fluid-flow analysis of ventilator as well
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1467-1472
Modeling of ship's shaft generator
Shaft generators, which are inserted in the shafting between the main propulsion engine and propeller, are important source of power on ships. Detailed knowledge of electromagnetic characteristics of shaft generator is necessary for design complex ship's power system. Such knowledge is obtainable only by numerical simulations. In this paper we simulate no-load and rated load electromagnetic state in low-speed ship's generator and present methodology for calculation of reactances from field solutions. Another important problem in design of shaft generator is dimensioning of cooling system because of limited space for the generator. Therefore, we present results of numerical fluid-flow analysis of ventilator as well
- 1 April 2003
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 27 (4) , 351-360
Method of moments in analysis of grounding systems
- 1 April 2003
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 27 (4) , 351-360
Method of moments in analysis of grounding systems
- 1 September 2001
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 15 (1-4) , 207-212
The least square deviations criterion and inverse-source magnetostatic problems
A procedure for the determination of the distribution of magnetization in an object of interest using measured disturbances of external magnetic field is described in the paper. The object is divided into a finite number of brick-shaped elements and we prescribe uniform distribution of magnetization within each element. The contribution of each element to the total magnetic field may be calculated analytically in terms of unknown coefficients of magnetization distribution. These coefficients are determined from a set of measured magnetic field values by application of the least square deviations criterion. Such an approach enables a priori analysis of stability of computation. The application of the procedure is illustrated by an example.
- 1 September 2001
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 15 (1-4) , 207-212
The least square deviations criterion and inverse-source magnetostatic problems
A procedure for the determination of the distribution of magnetization in an object of interest using measured disturbances of external magnetic field is described in the paper. The object is divided into a finite number of brick-shaped elements and we prescribe uniform distribution of magnetization within each element. The contribution of each element to the total magnetic field may be calculated analytically in terms of unknown coefficients of magnetization distribution. These coefficients are determined from a set of measured magnetic field values by application of the least square deviations criterion. Such an approach enables a priori analysis of stability of computation. The application of the procedure is illustrated by an example.