Mohamed H. Harajli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohamed H. Harajli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Elie G. Hantouche
Department of Civil and Environmental Engineering, American University of Beirut, Beirut, Lebanon
2 shared publications Amer M. ElSouri
Ph.D. Student, Dept. of Civil and Environmental Engineering, American Univ. of Beirut (AUB), Beirut, Lebanon
1 shared publicationAmer M. Elsouri
Department of Civil and Environmental Engineering, American University of Beirut (AUB), Beirut, Lebanon
1 shared publicationF. El Meski
Ph.D. Candidate, Dept. of Civil and Environmental Engineering, American Univ. of Beirut, Beirut 1107 2020, Lebanon
1 shared publicationH. ElKhatib
Professor, Dept. of Civil and Environmental Engineering, American Univ. of Beirut, Lebanon
1 shared publication- Jose Tomás San Jose
UPV/EHU
1 shared publication
Latest Publications
- 1 February 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 21 (1)
Generalized Axial Stress-Strain Response of Rectangular Columns Confined Using CFRP Jackets and Anchors
The results of an experimental study of the cyclic axial stress-strain response of rectangular concrete columns confined with a combination carbon-fiber-reinforced polymer (CFRP) jacket and CFRP anchors are presented and discussed. The test variables include aspect ratio of the column section, area of CFRP wraps, and area and configuration of the CFRP anchors. It was found that adding CFRP anchors improves the confinement effectiveness of the CFRP jackets, leading to substantially enhanced envelope stress-strain response and ductility of axial failure. Furthermore, changing the anchor configuration while maintaining the total anchors’ cross-sectional area does not produce a noticeable effect on the envelope stress-strain curve. The cyclic part of the stress-strain response of the CFRP-anchored specimens is similar to that of the companion specimens confined with CFRP sheets without anchors. Based on the results of this study, analytical expressions are derived for predicting the stress-strain curve, taking into account the effect of CFRP anchors. The proposed model is able to predict the envelope and cyclic responses of concrete columns confined with CFRP sheets only and columns confined with a combination of CFRP sheets and anchors.
- 1 February 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 21 (1)
Generalized Axial Stress-Strain Response of Rectangular Columns Confined Using CFRP Jackets and Anchors
The results of an experimental study of the cyclic axial stress-strain response of rectangular concrete columns confined with a combination carbon-fiber-reinforced polymer (CFRP) jacket and CFRP anchors are presented and discussed. The test variables include aspect ratio of the column section, area of CFRP wraps, and area and configuration of the CFRP anchors. It was found that adding CFRP anchors improves the confinement effectiveness of the CFRP jackets, leading to substantially enhanced envelope stress-strain response and ductility of axial failure. Furthermore, changing the anchor configuration while maintaining the total anchors’ cross-sectional area does not produce a noticeable effect on the envelope stress-strain curve. The cyclic part of the stress-strain response of the CFRP-anchored specimens is similar to that of the companion specimens confined with CFRP sheets without anchors. Based on the results of this study, analytical expressions are derived for predicting the stress-strain curve, taking into account the effect of CFRP anchors. The proposed model is able to predict the envelope and cyclic responses of concrete columns confined with CFRP sheets only and columns confined with a combination of CFRP sheets and anchors.
- 1 February 2015
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 18 (2) , 237-249
Repair and FRP Strengthening of Earthquake-Damaged RC Shallow Beam-Column Joints
Three earthquake-resistant wide beam-column joint specimens (one interior, and two exterior) which developed beam plastic hinging mechanism and beam flexural failure under large drift reversals were repaired and FRP strengthened for restoring their structural function. The repair and strengthening technique consisted of: (i) sealing the major flexural cracks that developed within the beam plastic hinge region using epoxy injection; (ii) adding carbon fiber-reinforced polymer (CFRP) reinforcement at the top and bottom faces of the beam to control the growth of the flexural cracks, boost up the beam negative and positive flexural capacities and at the same time compensate in part for the loss in the joint lateral stiffness; and (iii) providing CFRP jacket at the potential hinging regions of the columns for confining the concrete and enhancing the bond capacity of the spliced reinforcement. The effectiveness of the upgrading technique is demonstrated by comparing the performance of the upgraded joints when subjected to lateral cyclic loading against the performance of the same joints before damage. With its simplicity in application, the upgrading technique succeeded in bringing the damaged joints back into service conditions and in restoring their flexural stiffness under lateral load which degraded due to large drift reversals.
- 1 February 2015
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 18 (2) , 237-249
Repair and FRP Strengthening of Earthquake-Damaged RC Shallow Beam-Column Joints
Three earthquake-resistant wide beam-column joint specimens (one interior, and two exterior) which developed beam plastic hinging mechanism and beam flexural failure under large drift reversals were repaired and FRP strengthened for restoring their structural function. The repair and strengthening technique consisted of: (i) sealing the major flexural cracks that developed within the beam plastic hinge region using epoxy injection; (ii) adding carbon fiber-reinforced polymer (CFRP) reinforcement at the top and bottom faces of the beam to control the growth of the flexural cracks, boost up the beam negative and positive flexural capacities and at the same time compensate in part for the loss in the joint lateral stiffness; and (iii) providing CFRP jacket at the potential hinging regions of the columns for confining the concrete and enhancing the bond capacity of the spliced reinforcement. The effectiveness of the upgrading technique is demonstrated by comparing the performance of the upgraded joints when subjected to lateral cyclic loading against the performance of the same joints before damage. With its simplicity in application, the upgrading technique succeeded in bringing the damaged joints back into service conditions and in restoring their flexural stiffness under lateral load which degraded due to large drift reversals.
- 30 April 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 2068-2079
Seismic FRP Bond Strengthening of the Critical Splice Region in Wide Reinforced Concrete Columns
This paper presents preliminary results of a broader ongoing experimental study on the seismic bond strengthening of the critical reinforcement splice region in wide reinforced concrete (RC) columns or bridge piers confined with carbon fiber reinforced polymer (FRP) laminates and having bending about their minor axis. Large lateral drifts induced by strong earthquakes may result in splitting bond failure of the spliced bars, or rapid bond degradation at the splice location, leading to possible structural failure of the columns or piers. Previous research has verified the effectiveness of external confinement using FRP composites for improving bond performance of the spliced reinforcement of columns or piers having circular cross section, or rectangular cross section subjected to cyclic loading about their major axis. The preliminary experimental program reported in this paper consists of testing two full-scale wide column specimens under extreme substandard splice detailing associated with relatively short splice length, small concrete covers, small transverse spacing between the spliced bars, and complete absence of internal steel ties within the splice region. The test results showed that, despite extreme substandard splice detailing, the use of external FRP confinement improved the bond strength of the spliced bars, delayed the bond stiffness degradation under cyclic loading, and increased the energy dissipation capacity of the wide columns. However, the corresponding improvements were not as effective as anticipated. Consequently, before a final conclusion is drawn, more tests will be carried out on similar specimens but using instead more realistic and practical splice details as well as internal transverse steel ties for satisfying the minimum detailing requirements of the ACI 318-11 for gravity load designed axial members.
- 30 April 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 2068-2079
Seismic FRP Bond Strengthening of the Critical Splice Region in Wide Reinforced Concrete Columns
This paper presents preliminary results of a broader ongoing experimental study on the seismic bond strengthening of the critical reinforcement splice region in wide reinforced concrete (RC) columns or bridge piers confined with carbon fiber reinforced polymer (FRP) laminates and having bending about their minor axis. Large lateral drifts induced by strong earthquakes may result in splitting bond failure of the spliced bars, or rapid bond degradation at the splice location, leading to possible structural failure of the columns or piers. Previous research has verified the effectiveness of external confinement using FRP composites for improving bond performance of the spliced reinforcement of columns or piers having circular cross section, or rectangular cross section subjected to cyclic loading about their major axis. The preliminary experimental program reported in this paper consists of testing two full-scale wide column specimens under extreme substandard splice detailing associated with relatively short splice length, small concrete covers, small transverse spacing between the spliced bars, and complete absence of internal steel ties within the splice region. The test results showed that, despite extreme substandard splice detailing, the use of external FRP confinement improved the bond strength of the spliced bars, delayed the bond stiffness degradation under cyclic loading, and increased the energy dissipation capacity of the wide columns. However, the corresponding improvements were not as effective as anticipated. Consequently, before a final conclusion is drawn, more tests will be carried out on similar specimens but using instead more realistic and practical splice details as well as internal transverse steel ties for satisfying the minimum detailing requirements of the ACI 318-11 for gravity load designed axial members.
- 1 April 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (2) , 197-207
Flexural Behavior of Unbonded Posttensioned Concrete Members Strengthened Using External FRP Composites
This paper presents the results of an experimental study for evaluating the use of external fiber-reinforced polymer (FRP) laminates for strengthening unbonded posttensioned concrete members. Twenty-four full-scale simply supported beam and slab specimens reinforced with an internal unbonded tendon system and strengthened using external FRP composites were tested. An additional 12 companion bonded prestressed concrete (PC) and reinforced concrete (RC) specimens were also tested for comparison. The test parameters included area of internal tension reinforcement, area of external FRP reinforcement, span-to-depth ratio of the member (slab, beam), and profile of the unbonded tendons. It was found that the use of FRP laminates increases the load capacity and postcracking stiffness of unbonded members. The increase in load capacity was accompanied by a reduction in the deformation capacity. Failure of the specimens occurred either by concrete crushing or by FRP debonding or FRP fracture. No distinct dif...
- 1 April 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (2) , 197-207
Flexural Behavior of Unbonded Posttensioned Concrete Members Strengthened Using External FRP Composites
This paper presents the results of an experimental study for evaluating the use of external fiber-reinforced polymer (FRP) laminates for strengthening unbonded posttensioned concrete members. Twenty-four full-scale simply supported beam and slab specimens reinforced with an internal unbonded tendon system and strengthened using external FRP composites were tested. An additional 12 companion bonded prestressed concrete (PC) and reinforced concrete (RC) specimens were also tested for comparison. The test parameters included area of internal tension reinforcement, area of external FRP reinforcement, span-to-depth ratio of the member (slab, beam), and profile of the unbonded tendons. It was found that the use of FRP laminates increases the load capacity and postcracking stiffness of unbonded members. The increase in load capacity was accompanied by a reduction in the deformation capacity. Failure of the specimens occurred either by concrete crushing or by FRP debonding or FRP fracture. No distinct dif...
- 1 November 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 16 (6) , 828-838
Proposed Modification of AASHTO-LRFD for Computing Stress in Unbonded Tendons at Ultimate
In 1998, AASHTO-LRFD adopted a new equation for evaluating the stress fps in unbonded tendons at ultimate. In explaining the development and applicability of the new AASHTO-LRFD equation, some investigators concluded that the new equation is conservative and more rational when compared with the ACI building code approach for computing fps. However, in a comprehensive study carried out by the writer, it was found that while the AASHTO-LRFD equation is indeed more rational than the ACI building code approach because it accounts for continuous members, it still encounters significant scatter in predicting test data. Also, using conservative collapse mechanisms that involve loading a single span in a multispan member for all loading cases as proposed in AASHTO-LRFD leads to design inconsistencies. Based on the results of this assessment, supported by a large body of test data, an expression for evaluating the equivalent plastic-hinge length in unbonded members at ultimate was developed. The corresponding expr...
- 1 November 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 16 (6) , 828-838
Proposed Modification of AASHTO-LRFD for Computing Stress in Unbonded Tendons at Ultimate
In 1998, AASHTO-LRFD adopted a new equation for evaluating the stress fps in unbonded tendons at ultimate. In explaining the development and applicability of the new AASHTO-LRFD equation, some investigators concluded that the new equation is conservative and more rational when compared with the ACI building code approach for computing fps. However, in a comprehensive study carried out by the writer, it was found that while the AASHTO-LRFD equation is indeed more rational than the ACI building code approach because it accounts for continuous members, it still encounters significant scatter in predicting test data. Also, using conservative collapse mechanisms that involve loading a single span in a multispan member for all loading cases as proposed in AASHTO-LRFD leads to design inconsistencies. Based on the results of this assessment, supported by a large body of test data, an expression for evaluating the equivalent plastic-hinge length in unbonded members at ultimate was developed. The corresponding expr...
- 1 October 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (5) , 721-731
Seismic Repair and Strengthening of Lap Splices in RC Columns: Carbon Fiber–Reinforced Polymer versus Steel Confinement
A design approach, developed specifically for seismic bond strengthening of the critical splice region of reinforced concrete columns or bridge piers, is presented and discussed. The approach is based on providing adequate concrete confinement within the splice zone for allowing the spliced bars to theoretically develop enough postelastic tension strains demanded by large earthquakes before experiencing splitting bond failure. The accuracy of the approach was validated experimentally by evaluating the seismic behavior of full-scale gravity load-designed (as-built) rectangular columns that were strengthened or repaired in accordance with the proposed approach. Three types of confinement were used and compared, namely, internal steel ties, external fiber polymer reinforced jackets, and a combination of both. The repaired/strengthened columns developed sizable postyield strains of the spliced bars, considerable increases in the lateral load and drift capacities, and much less concrete damage within the splic...
- 1 October 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (5) , 721-731
Seismic Repair and Strengthening of Lap Splices in RC Columns: Carbon Fiber–Reinforced Polymer versus Steel Confinement
A design approach, developed specifically for seismic bond strengthening of the critical splice region of reinforced concrete columns or bridge piers, is presented and discussed. The approach is based on providing adequate concrete confinement within the splice zone for allowing the spliced bars to theoretically develop enough postelastic tension strains demanded by large earthquakes before experiencing splitting bond failure. The accuracy of the approach was validated experimentally by evaluating the seismic behavior of full-scale gravity load-designed (as-built) rectangular columns that were strengthened or repaired in accordance with the proposed approach. Three types of confinement were used and compared, namely, internal steel ties, external fiber polymer reinforced jackets, and a combination of both. The repaired/strengthened columns developed sizable postyield strains of the spliced bars, considerable increases in the lateral load and drift capacities, and much less concrete damage within the splic...
- 1 November 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (11) , 1171-1180
Static and Cyclic Out-of-Plane Response of Masonry Walls Strengthened Using Textile-Mortar System
The work presented in this paper is a part of a comprehensive research project aimed at developing and testing a system for strengthening historical buildings. The system is composed of a combination of textile mesh and mortar. Representative wall specimens were tested for their out-of-plane flexural behavior under static and cyclic loadings. The parameters investigated include the types of masonry wall (concrete block, sandstone, and brick), mortar (natural lime and cement-based), and textile (bitumen coated E-glass, basalt, or coated basalt fibers). Companion specimens, strengthened using a steel wire mesh, were also tested for comparison. All textile-mortar reinforced masonry (TRM) wall specimens failed in a combination of transverse detachment of the textile-mortar matrix due to the transverse displacement of the blocks relative to each other, and combined transverse shear-tension fracturing of the textile fibers. Regardless of the mode of failure, the TRM specimens developed a substantial increase in...
- 1 November 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (11) , 1171-1180
Static and Cyclic Out-of-Plane Response of Masonry Walls Strengthened Using Textile-Mortar System
The work presented in this paper is a part of a comprehensive research project aimed at developing and testing a system for strengthening historical buildings. The system is composed of a combination of textile mesh and mortar. Representative wall specimens were tested for their out-of-plane flexural behavior under static and cyclic loadings. The parameters investigated include the types of masonry wall (concrete block, sandstone, and brick), mortar (natural lime and cement-based), and textile (bitumen coated E-glass, basalt, or coated basalt fibers). Companion specimens, strengthened using a steel wire mesh, were also tested for comparison. All textile-mortar reinforced masonry (TRM) wall specimens failed in a combination of transverse detachment of the textile-mortar matrix due to the transverse displacement of the blocks relative to each other, and combined transverse shear-tension fracturing of the textile fibers. Regardless of the mode of failure, the TRM specimens developed a substantial increase in...
- 1 July 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (7) , 674-686
Bond Behavior in Steel Fiber-Reinforced Concrete Zones under Static and Cyclic Loading: Experimental Evaluations and Analytical Modeling
There is a renewed interest in using steel fiber reinforcement within the critical hinging regions of reinforced concrete (RC) members as a means for improving their seismic response. Examples include beam-column joints, structural walls, and shear walls coupling beams. The presence of steel fiber reinforcement in these regions confines the concrete, improves the bond strength of the steel bars, and reduces the bond degradation, leading to reduced damage and increased energy absorption and dissipation capacities under cyclic loading. This paper presents a synthesis of the results of a series of experimental and analytical investigations undertaken by the writer on the use of steel fiber reinforcement for improving the bond capacity and bond stress-slip response of steel bars under static and cyclic loading and its implication on the static and seismic response of RC members. The experimental results are discussed, a design expression for evaluating the effect of fiber reinforcement on the bond or developm...
- 1 July 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 22 (7) , 674-686
Bond Behavior in Steel Fiber-Reinforced Concrete Zones under Static and Cyclic Loading: Experimental Evaluations and Analytical Modeling
There is a renewed interest in using steel fiber reinforcement within the critical hinging regions of reinforced concrete (RC) members as a means for improving their seismic response. Examples include beam-column joints, structural walls, and shear walls coupling beams. The presence of steel fiber reinforcement in these regions confines the concrete, improves the bond strength of the steel bars, and reduces the bond degradation, leading to reduced damage and increased energy absorption and dissipation capacities under cyclic loading. This paper presents a synthesis of the results of a series of experimental and analytical investigations undertaken by the writer on the use of steel fiber reinforcement for improving the bond capacity and bond stress-slip response of steel bars under static and cyclic loading and its implication on the static and seismic response of RC members. The experimental results are discussed, a design expression for evaluating the effect of fiber reinforcement on the bond or developm...
- 1 May 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (5) , 509-518
Bond Stress–Slip Model for Steel Bars in Unconfined or Steel, FRC, or FRP Confined Concrete under Cyclic Loading
An experimentally based relationship of the cyclic local bond stress–slip response of steel bars corresponding to splitting mode of bond failure is developed. The relationship is composed of a monotonic envelope response and cyclic bond degrading response. The model accounts for both unconfined and moderately confined concrete and incorporates the effect of several critical bond parameters such as the diameter of steel bars, the ratio of concrete cover to bar diameter, the concrete compressive strength, the type of confinement such as steel ties, fiber-reinforced concrete (FRC), and fiber-reinforced polymer jackets, and the area or content of confining reinforcement. Results predicted by the model showed very good agreement with the test data. The bond–slip relationship can be utilized for evaluating the seismic behavior and bond degradation response of bond-critical regions in reinforced concrete members when confined internally with steel ties or fiber reinforced concrete or retrofitted using external F...
- 1 May 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (5) , 509-518
Bond Stress–Slip Model for Steel Bars in Unconfined or Steel, FRC, or FRP Confined Concrete under Cyclic Loading
An experimentally based relationship of the cyclic local bond stress–slip response of steel bars corresponding to splitting mode of bond failure is developed. The relationship is composed of a monotonic envelope response and cyclic bond degrading response. The model accounts for both unconfined and moderately confined concrete and incorporates the effect of several critical bond parameters such as the diameter of steel bars, the ratio of concrete cover to bar diameter, the concrete compressive strength, the type of confinement such as steel ties, fiber-reinforced concrete (FRC), and fiber-reinforced polymer jackets, and the area or content of confining reinforcement. Results predicted by the model showed very good agreement with the test data. The bond–slip relationship can be utilized for evaluating the seismic behavior and bond degradation response of bond-critical regions in reinforced concrete members when confined internally with steel ties or fiber reinforced concrete or retrofitted using external F...
- 1 February 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 12 (1) , 69-79
Seismic Behavior of RC Columns with Bond-Critical Regions: Criteria for Bond Strengthening Using External FRP Jackets
In 2003, an experimental research program was initiated at the American University of Beirut with the objectives of (1) evaluating the effectiveness of external fiber-reinforced polymer (FRP) confinement in improving the bond strength of spliced reinforcement in reinforced-concrete (RC) columns and its implications on the lateral load capacity and ductility of the columns under seismic loading; and (2) establishing rational design criteria for bond strengthening of spliced reinforcement using external FRP jackets. This paper presents a discussion of recent experimental results dealing with rectangular columns and the results of a pilot study conducted on circular columns with particular emphasis on aspects related to the bond strength of the spliced column reinforcement. A nonlinear analysis model is developed for predicting the envelope load–drift response, taking into account the effect of FRP confinement on the stress–strain behavior of concrete in compression. Results predicted by the model showed excellent agreement with the test results. Design expressions of the bond strength of spliced bars in FRP-confined concrete were assessed against the current experimental data, and a criterion for seismic FRP strengthening of bond-critical regions in RC members is proposed.
- 1 February 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 12 (1) , 69-79
Seismic Behavior of RC Columns with Bond-Critical Regions: Criteria for Bond Strengthening Using External FRP Jackets
In 2003, an experimental research program was initiated at the American University of Beirut with the objectives of (1) evaluating the effectiveness of external fiber-reinforced polymer (FRP) confinement in improving the bond strength of spliced reinforcement in reinforced-concrete (RC) columns and its implications on the lateral load capacity and ductility of the columns under seismic loading; and (2) establishing rational design criteria for bond strengthening of spliced reinforcement using external FRP jackets. This paper presents a discussion of recent experimental results dealing with rectangular columns and the results of a pilot study conducted on circular columns with particular emphasis on aspects related to the bond strength of the spliced column reinforcement. A nonlinear analysis model is developed for predicting the envelope load–drift response, taking into account the effect of FRP confinement on the stress–strain behavior of concrete in compression. Results predicted by the model showed excellent agreement with the test results. Design expressions of the bond strength of spliced bars in FRP-confined concrete were assessed against the current experimental data, and a criterion for seismic FRP strengthening of bond-critical regions in RC members is proposed.