Jean-Pierre Guigay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean-Pierre Guigay has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
C. Ferrero
ESRF, CS40220, Grenoble, 38043, France
3 shared publications- Peter Cloetens
European Synchrotron Radiation Facility
2 shared publications - Vito Mocella
Istituto per la Microelettronica e Microsistemi, CNR (Italy)
2 shared publications Ch. Morawe
ESRF, BP 220, 6, rue Jules Horowitz, F-38043 Grenoble cedex, France
1 shared publicationChristian David
Paul Scherrer Institut, CH-5232 Villigen, Switzerland
1 shared publication- Claudio Ferrero
European Synchrotron Radiation Facility, 38000 Grenoble, France
1 shared publication
Latest Publications
- 29 June 2016
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 72 (4) , 489-499
Dynamical focusing by bent, asymmetrically cut perfect crystals in Laue geometry
A semi-analytical approach based on the influence functions of a point source located on the crystal surface has been adopted to show that the focusing ability of cylindrically bent Laue crystals may be strongly enhanced by replacing symmetrically cut crystals with asymmetrically cut crystals. This approach is generally applicable to any distance between the X-ray source and the focusing bent crystal. A mathematically straightforward method to simplify the derivation of the already known expression of the influence functions in the case of deformed crystals with a constant strain gradient (e.g.cylindrically bent crystals) is also presented.
- 29 June 2016
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 72 (4) , 489-499
Dynamical focusing by bent, asymmetrically cut perfect crystals in Laue geometry
A semi-analytical approach based on the influence functions of a point source located on the crystal surface has been adopted to show that the focusing ability of cylindrically bent Laue crystals may be strongly enhanced by replacing symmetrically cut crystals with asymmetrically cut crystals. This approach is generally applicable to any distance between the X-ray source and the focusing bent crystal. A mathematically straightforward method to simplify the derivation of the already known expression of the influence functions in the case of deformed crystals with a constant strain gradient (e.g.cylindrically bent crystals) is also presented.
- 12 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9510, 95100
Dynamical diffraction approach of deformed crystals using finite element method
- 12 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9510, 95100
Dynamical diffraction approach of deformed crystals using finite element method
- 30 November 2012
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 69 (1) , 91-97
Bent perfect crystals as X-ray focusing polychromators in symmetric Laue geometry
The focusing properties of cylindrically bent crystals in symmetric Laue geometry are discussed using the formalism of Fresnel diffraction and the analytical solution of the Takagi-Taupin equations for a point source on the entrance surface. The existence of a focal shift in the dynamical focusing effect is pointed out and discussed. The present theoretical framework is applied to experiments performed at the energy-dispersive X-ray absorption spectroscopy beamline of the European Synchrotron Radiation Facility concerning the position and the size of the focal spot obtained from a polychromatic source at a large distance from the bent crystal.
- 30 November 2012
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 69 (1) , 91-97
Bent perfect crystals as X-ray focusing polychromators in symmetric Laue geometry
The focusing properties of cylindrically bent crystals in symmetric Laue geometry are discussed using the formalism of Fresnel diffraction and the analytical solution of the Takagi-Taupin equations for a point source on the entrance surface. The existence of a focal shift in the dynamical focusing effect is pointed out and discussed. The present theoretical framework is applied to experiments performed at the energy-dispersive X-ray absorption spectroscopy beamline of the European Synchrotron Radiation Facility concerning the position and the size of the focal spot obtained from a polychromatic source at a large distance from the bent crystal.
- 28 July 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (16) , 12050-12059
An analytical approach to estimating aberrations in curved multilayer optics for hard x-rays: 1. Derivation of caustic shapes
An analytical approach has been developed to derive aberration effects in parabolic and elliptic multilayer optics with weak interaction between photons and matter. The method is based on geometrical ray tracing including refraction effects up to the first order of the refractive index decrement δ. In the parabolic case, the derivation leads to simple parametric equations for the caustic shape. In the elliptic case, the analytical results more involved, but can be well approximated by the parabolic solution. Both geometries are compared with regard to the fundamental impact on their focusing properties.
- 28 July 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (16) , 12050-12059
An analytical approach to estimating aberrations in curved multilayer optics for hard x-rays: 1. Derivation of caustic shapes
An analytical approach has been developed to derive aberration effects in parabolic and elliptic multilayer optics with weak interaction between photons and matter. The method is based on geometrical ray tracing including refraction effects up to the first order of the refractive index decrement δ. In the parabolic case, the derivation leads to simple parametric equations for the caustic shape. In the elliptic case, the analytical results more involved, but can be well approximated by the parabolic solution. Both geometries are compared with regard to the fundamental impact on their focusing properties.
- 15 February 2007
- Published by Elsevier in Optics Communications
- Vol. 270 (2) , 180-188
Fourier optics approach to X-ray analyser-based imaging
- 15 February 2007
- Published by Elsevier in Optics Communications
- Vol. 270 (2) , 180-188
Fourier optics approach to X-ray analyser-based imaging
- 1 October 2006
- Published by International Union of Crystallography (IUCr)
- p. 557-569
Dynamical theory of neutron diffraction
- 1 October 2006
- Published by International Union of Crystallography (IUCr)
- p. 557-569
Dynamical theory of neutron diffraction
- Open Access
- 22 October 2004
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 11 (6) , 476-482
The partial Talbot effect and its use in measuring the coherence of synchrotron X-rays
The Talbot effect is the self-imaging, at distances D multiple of D(R), of the intensity downstream of a periodic object. Earlier work with hard synchrotron radiation X-rays showed the variation with D of the fundamental Fourier component of intensity to be a good measurement of beam coherence. Any higher-order Fourier coefficients I (D, m > 1) would be periodic with a reduced period D(Rm) = D(R)/m for an ideally coherent incident beam (partial Talbot effect). The degree of coherence gamma(x) is sampled through the ratio of I (D, m) at D = 0 and multiples of D(Rm). This requires the Fourier coefficient for D = 0, which is not accessible for a phase object (no contrast at D = 0). However, the ratio of the slopes of I (D, m) at D = 0 and D = pD(Rm) also provides this information. Furthermore, a characterization of gamma(x) is possible, provided an assumption is made on its shape, using only the ratio of the Fourier coefficient I (D, m) of two images a distance pD(Rm) apart. Experiments with one- and two-dimensional phase gratings and a mixed (amplitude and phase) two-dimensional grating confirm that the partial Talbot effect approach is viable. It requires a reduced range of distances, and yields important results directly, obviating the need for computer fits. In particular, 8% of the beam intensity was found to have very low coherence in the vertical direction, probably due to monochromator imperfection.
- 22 October 2004
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 11 (6) , 476-482
Open AccessThe partial Talbot effect and its use in measuring the coherence of synchrotron X-rays
The Talbot effect is the self-imaging, at distances D multiple of D(R), of the intensity downstream of a periodic object. Earlier work with hard synchrotron radiation X-rays showed the variation with D of the fundamental Fourier component of intensity to be a good measurement of beam coherence. Any higher-order Fourier coefficients I (D, m > 1) would be periodic with a reduced period D(Rm) = D(R)/m for an ideally coherent incident beam (partial Talbot effect). The degree of coherence gamma(x) is sampled through the ratio of I (D, m) at D = 0 and multiples of D(Rm). This requires the Fourier coefficient for D = 0, which is not accessible for a phase object (no contrast at D = 0). However, the ratio of the slopes of I (D, m) at D = 0 and D = pD(Rm) also provides this information. Furthermore, a characterization of gamma(x) is possible, provided an assumption is made on its shape, using only the ratio of the Fourier coefficient I (D, m) of two images a distance pD(Rm) apart. Experiments with one- and two-dimensional phase gratings and a mixed (amplitude and phase) two-dimensional grating confirm that the partial Talbot effect approach is viable. It requires a reduced range of distances, and yields important results directly, obviating the need for computer fits. In particular, 8% of the beam intensity was found to have very low coherence in the vertical direction, probably due to monochromator imperfection.
- 1 May 1999
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 55 (3) , 561-563
A simple view of the spherical wave in dynamical theory
The results of the Kato spherical-wave approach to the dynamical theory for perfect crystals are obtained by a simple and straightforward method based on the multiple-scattering expansion.
- 1 May 1999
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 55 (3) , 561-563
A simple view of the spherical wave in dynamical theory
The results of the Kato spherical-wave approach to the dynamical theory for perfect crystals are obtained by a simple and straightforward method based on the multiple-scattering expansion.