Janusz Podliński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Janusz Podliński has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
J. Mizeraczyk
Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid Flow Machinery, Polish Academy of Sciences
3 shared publicationsJerzy Mizeraczyk
Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid Flow Machinery, Polish Academy of Sciences
3 shared publications- Anna Niewulis
Polish Academy of Sciences
2 shared publications Marek Kocik
Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid Flow Machinery, Polish Academy of Sciences
2 shared publications- Mirosław Dors
Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdansk, Poland
2 shared publications A. Mizuno
Toyohashi University of Technology, Tempaku-cho
1 shared publication
Latest Publications
- Open Access
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11596
Imaging and Optical Emission Spectroscopy of Surface Dielectric Barrier Discharge (SDBD) Plasma Generated Using Reactors with Planar and Cylindrical Electrodes
We characterized non-thermal plasma generated in two types of Surface Dielectric Barrier Discharge (SDBD) reactors, one with a planar and the other with a cylindrical electrode. Plasma was examined using the time-resolved imaging and Optical Emission Spectroscopy (OES) methods. We observed that the cylindrical electrode suppresses plasma formation during both discharge modes: positive streamers and pseudo-Trichel microdischarges. The propagation velocity of the plasma front was estimated to be in the range 12–15 m/s, regardless of the discharge mode and electrode type. Spectral analysis showed that the plasma emission spectrum consisted mainly of the first and second positive nitrogen bands. Using Specair software, we calculated the plasma thermodynamic parameters and found that, despite morphological differences, the plasma generated in both reactors had similar thermodynamic properties. Finally, we discussed the temporal evolution of the discharge and attributed the plasma suppression caused by the cylindrical electrode to the characteristic uniformity of the electric field around and along this electrode.
- 12 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11596
Open AccessImaging and Optical Emission Spectroscopy of Surface Dielectric Barrier Discharge (SDBD) Plasma Generated Using Reactors with Planar and Cylindrical Electrodes
We characterized non-thermal plasma generated in two types of Surface Dielectric Barrier Discharge (SDBD) reactors, one with a planar and the other with a cylindrical electrode. Plasma was examined using the time-resolved imaging and Optical Emission Spectroscopy (OES) methods. We observed that the cylindrical electrode suppresses plasma formation during both discharge modes: positive streamers and pseudo-Trichel microdischarges. The propagation velocity of the plasma front was estimated to be in the range 12–15 m/s, regardless of the discharge mode and electrode type. Spectral analysis showed that the plasma emission spectrum consisted mainly of the first and second positive nitrogen bands. Using Specair software, we calculated the plasma thermodynamic parameters and found that, despite morphological differences, the plasma generated in both reactors had similar thermodynamic properties. Finally, we discussed the temporal evolution of the discharge and attributed the plasma suppression caused by the cylindrical electrode to the characteristic uniformity of the electric field around and along this electrode.
- 16 August 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (1)
Electrohydrodynamic Pump Supplied by Unipolar Direct Current Voltage With Both Positive and Negative Corona Discharge
Strong electric field applied between the two electrodes initiates a corona discharge, which results in ionization of gas molecules and induces ionic wind, also known as the electrohydrodynamic (EHD) flow. If an electric field is asymmetric, then a unidirectional gas flow can be formed causing so-called EHD gas pumping. In spite of many experiments with different electrode shapes and configurations such as needle-to-mesh, needle-to-ring, wire-to-rod, wire-to-non-parallel plates, etc., aimed at production of intensive gas pumping, the investigated EHD pumps were most often unsatisfactory. In our research, we proposed a new configuration of electrodes for the EHD pump, where all electrodes (excluding the first one and the last one) are simultaneously the discharge (on one side) and the collecting (on the other side) electrodes. Our electrodes configuration can be easily multiplied without additional space between consecutive electrodes. In such a case, a high ratio of pumping efficiency to pump size can be obtained. The Time-Resolved Particle Image Velocimetry technique was used to investigate the EHD flow generated by our EHD pump.
- 16 August 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (1)
Electrohydrodynamic Pump Supplied by Unipolar Direct Current Voltage With Both Positive and Negative Corona Discharge
Strong electric field applied between the two electrodes initiates a corona discharge, which results in ionization of gas molecules and induces ionic wind, also known as the electrohydrodynamic (EHD) flow. If an electric field is asymmetric, then a unidirectional gas flow can be formed causing so-called EHD gas pumping. In spite of many experiments with different electrode shapes and configurations such as needle-to-mesh, needle-to-ring, wire-to-rod, wire-to-non-parallel plates, etc., aimed at production of intensive gas pumping, the investigated EHD pumps were most often unsatisfactory. In our research, we proposed a new configuration of electrodes for the EHD pump, where all electrodes (excluding the first one and the last one) are simultaneously the discharge (on one side) and the collecting (on the other side) electrodes. Our electrodes configuration can be easily multiplied without additional space between consecutive electrodes. In such a case, a high ratio of pumping efficiency to pump size can be obtained. The Time-Resolved Particle Image Velocimetry technique was used to investigate the EHD flow generated by our EHD pump.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (3) , 601-607
Flow Distribution Measurement in Wire-nonparallel Plate Type Electrohydrodynamic Gas Pump by a Particle Image Velocimetry
2D Particle Image Velocimetry (PIV) measurements were performed in a wire-nonparallel plates type electrohydrodynamic (EHD) gas pump. The effect of electrode configuration and polarity of the active electrode on the flow pattern inside the pump was studied. One can deduce from the obtained flow patterns that the flow generated inside the EHD pump is three dimensional. The vortices formed inside the EHD gas pump have negative effect on pumping capabilities of the pump since the vortices may block and suppress the generated flow. The PIV results will be compared with a numerical modelling of the flow, based on k-E model.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (3) , 601-607
Flow Distribution Measurement in Wire-nonparallel Plate Type Electrohydrodynamic Gas Pump by a Particle Image Velocimetry
2D Particle Image Velocimetry (PIV) measurements were performed in a wire-nonparallel plates type electrohydrodynamic (EHD) gas pump. The effect of electrode configuration and polarity of the active electrode on the flow pattern inside the pump was studied. One can deduce from the obtained flow patterns that the flow generated inside the EHD pump is three dimensional. The vortices formed inside the EHD gas pump have negative effect on pumping capabilities of the pump since the vortices may block and suppress the generated flow. The PIV results will be compared with a numerical modelling of the flow, based on k-E model.
- 13 February 2009
- Published by Springer Nature in The European Physical Journal D
- Vol. 54 (2) , 153-158
Electrohydrodynamic flow in a wire-plate non-thermal plasma reactor measured by 3D PIV method
- 13 February 2009
- Published by Springer Nature in The European Physical Journal D
- Vol. 54 (2) , 153-158
Electrohydrodynamic flow in a wire-plate non-thermal plasma reactor measured by 3D PIV method
- 1 January 2009
- Published by Springer Nature
- p. 134-139
Electrohydrodynamic Turbulent Flow in a Wide Wire-Plate Electrostatic Precipitator Measured by 3D PIV Method
- 1 January 2009
- Published by Springer Nature
- p. 134-139
Electrohydrodynamic Turbulent Flow in a Wide Wire-Plate Electrostatic Precipitator Measured by 3D PIV Method
- 2 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6604, 660412
CuBr laser visulization of the bubbles flow in a pulsed discharge in water
In this work results of the laser visualization of the gas bubbles flow in a needle-to-cylinder pulsed discharge reactor filled with distilled water are presented. The experimental setup consisted of a pulsed discharge reactor, high voltage supply, CuBr laser, and Video camera. In the glass reactor bottom a stressed needle or a set of needles were placed. The grounded cylinder was set 45 mm above the needle electrode(s). The pulses of positive voltage (up to 31 kV) with a repetition rate of 50 Hz were used. A laser beam emitted from the CuBr laser was formed, using a telescope, into the laser sheet, which crossed the reactor in a selected vertical and horizontal plains. It was observed that during the positive pulsed discharge in water the bubbles production and the streamer size increased with increasing applied voltage. Large vortices generated during the discharge distributed bubbles in the whole reactor volume, providing good mixing and distribution of active species. The more needles were used, the larger number of bubbles were observed.
- 2 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6604, 660412
CuBr laser visulization of the bubbles flow in a pulsed discharge in water
In this work results of the laser visualization of the gas bubbles flow in a needle-to-cylinder pulsed discharge reactor filled with distilled water are presented. The experimental setup consisted of a pulsed discharge reactor, high voltage supply, CuBr laser, and Video camera. In the glass reactor bottom a stressed needle or a set of needles were placed. The grounded cylinder was set 45 mm above the needle electrode(s). The pulses of positive voltage (up to 31 kV) with a repetition rate of 50 Hz were used. A laser beam emitted from the CuBr laser was formed, using a telescope, into the laser sheet, which crossed the reactor in a selected vertical and horizontal plains. It was observed that during the positive pulsed discharge in water the bubbles production and the streamer size increased with increasing applied voltage. Large vortices generated during the discharge distributed bubbles in the whole reactor volume, providing good mixing and distribution of active species. The more needles were used, the larger number of bubbles were observed.
- 1 October 2006
- Published by Springer Nature in Czechoslovak Journal of Physics
- Vol. 56 (S2) , B1009-B1016
3D PIV measurements of the EHD flow patterns in a narrow lectrostatic precipitator with wire-plate or wire-flocking electrodes
- 1 October 2006
- Published by Springer Nature in Czechoslovak Journal of Physics
- Vol. 56 (S2) , B1009-B1016
3D PIV measurements of the EHD flow patterns in a narrow lectrostatic precipitator with wire-plate or wire-flocking electrodes
- 16 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6598, 65980W
Flow diagnostics using particle image velocimetry method
The Particle Image Velocimetry (PIV) technique for measuring of velocity flow fields was presented. The PIV measurement principle was described together with experimental techniques used for both 2D and 3D PIV. The application of PIV method in a hydrodynamic tunnel, towing tank, non-thermal plasma reactors and ESP were discussed.
- 16 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6598, 65980W
Flow diagnostics using particle image velocimetry method
The Particle Image Velocimetry (PIV) technique for measuring of velocity flow fields was presented. The PIV measurement principle was described together with experimental techniques used for both 2D and 3D PIV. The application of PIV method in a hydrodynamic tunnel, towing tank, non-thermal plasma reactors and ESP were discussed.