CLChristina Lindh

Christina Lindh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christina Lindh has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Craniofacial height in relation to cross-sectional maxillary and mandibular morphology

    by Anna Klinge, Karin Becktor, Christina Lindh, Jonas P Becktor

    In order to gain a better understanding of how growth of the alveolar bone is linked to the vertical development of the face, the purpose of this study was to investigate if there is an association between the cross-sectional morphology of the maxillary and mandibular bodies with the craniofacial height, using images from cone beam computed tomography (CBCT). From 450 pre-treatment CBCT scans, 180 were selected to be included in the study. Lateral head images were generated from the CBCT scans and were used to categorise subjects into three groups based on their vertical craniofacial height. Cross-sectional images from CBCT volumes were reformatted of the maxillary and mandibular bodies at five locations in the maxilla and five in the mandible. Each image was measured at one height and two width measurements. Statistical analysis performed was the one-way analysis of variance with a Tukey post hoc test. A significance level of 5% was used in all comparisons. Patients with large vertical craniofacial height had a significantly higher cross-sectional area both in the maxilla and in the mandible. In the same group, the cross-sectional area was significantly thinner in the mandible compared with the other two groups, especially in the anterior region. This study further highlights the close relationship between craniofacial height and alveolar bone dimensions and contributes with important knowledge for planning and follow-up of comprehensive dental- and orthodontic treatments.


  • Dose optimization for assessment of periodontal structures in cone beam CT examinations

    by Ayman Al-Okshi, Chrysoula Theodorakou, Christina Lindh

    Objective:To investigate the relationship between dose and image quality for a dedicated dental Cone Beam CT (CBCT) scanner using different scanning protocols and to set up an optimal imaging protocol for assessment of periodontal structures.Methods:Radiation dose and image quality measurements were made using the 3D Accuitomo 170 dental CBCT scanner. The SedentexCT IQ phantom was used to investigate the relationship between contrast-to-noise ratio (CNR) and dose-area product (DAP). Subjective image quality assessment was achieved using a small adult skull phantom for the same range of exposure settings. Five independent observers assessed the images for three anatomical landmarks using a three-point visual grade analysis.Results:When correlating the CNR of each scanning protocol to the exposure parameters used to obtain it, CNR decreased as these parameters decreased, especially current–exposure time product. When correlating to subjective image quality, the CNR level remained acceptable when 5mA and 17....


  • Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review

    by A Al-Okshi, C Lindh, H Salé, M Gunnarsson, M Rohlin

    To estimate effective dose of cone beam CT (CBCT) of the facial skeleton with focus on measurement methods and scanning protocols. A systematic review, which adhered to the preferred reporting items for systematic reviews (PRISMA) Statement, of the literature up to April 2014 was conducted. Data sources included MEDLINE®, The Cochrane Library and Web of Science. A model was developed to underpin data extraction from 38 included studies. Technical specifications of the CBCT units were insufficiently described. Heterogeneity in measurement methods and scanning protocols between studies made comparisons of effective doses of different CBCT units and scanning protocols difficult. Few studies related doses to image quality. Reported effective dose varied across studies, ranging between 9.7 and 197.0 μSv for field of views (FOVs) with height ≤5 cm, between 3.9 and 674.0 μSv for FOVs of heights 5.1-10.0 cm and between 8.8 and 1073.0 μSv for FOVs >10 cm. There was an inconsistency regarding reported effective dose of studies of the same CBCT unit with the same FOV dimensions. The review reveals a need for studies on radiation dosages related to image quality. Reporting quality of future studies has to be improved to facilitate comparison of effective doses obtained from examinations with different CBCT units and scanning protocols. A model with minimum data set on important parameters based on this observation is proposed. Data important when estimating effective dose were insufficiently reported in most studies. A model with minimum data based on this observation is proposed. Few studies related effective dose to image quality.


  • A predictive model for alternative admission to dental education

    by C. Christersson, D. Bengmark, H. Bengtsson, C. Lindh, M. Rohlin

    Aim: To compare academic progress and performance of students admitted through two admission systems and to analyse the predictive power of different components in an alternative admission.Sample and Methods: The subjects were students admitted to the dental programme at Malmö University, Sweden. The grade admission group was admitted on grades from secondary school (n = 126) and the alternative admission group via an alternative admission procedure (n = 157). The alternative admission procedure consisted of the following components: problem‐solving matrices, spatial capacity tested with folding and tin models, manual dexterity, capacity for empathy and interview. Comparisons were made for academic progress (dropouts from the programme and study rate) and academic performance (examinations failed and outcomes of a comprehensive clinical examination). Spearman correlation was calculated for each component of the alternative admission procedure and academic progress as well as academic performance. Multivariate analyses were also carried out.Results: Compared to the grade admission group, the alternative admission group presented lower rate of dropsouts (3% vs. 20%, P < 0.001) and a larger proportion graduated within the expected time (88% vs. 60%, P < 0.01). There was no difference between the groups concerning academic performance. Capacity of empathy was correlated with study rate and outcomes of the clinical examination. The matrices predicted low proportion failed examinations and high students' self‐assessments in the clinical examination. Predictive power of folding was limited and so was that of the interview. Manual dexterity was not correlated with academic progress or performance.Conclusions: Results support further development of admission selection criteria, particularly emphatic capacity that predicts important student academic achievements.


  • Bone quality assessment in routine dental implant treatment amongBrazilian andSwedish specialists

    by Christina Lindh, Guilherme Henrique C. Oliveira, Cláudio R. Leles, Maria Do Carmo Matias Freire, Rejane F. Ribeiro‐Rotta

    Objectives: To investigate the interpretation and assessment of bone quality amongBrazilian andSwedish specialist performing implant treatment.Material and methods: A questionnaire was developed containing open and closed questions on attitudes, knowledge, and understanding of diagnostic methods for bone quality assessment. The questionnaire was sent by mail to dental implant specialists inBrazil while theSwedish version wasWeb‐based and sent to specialists in periodontology and maxillofacial surgery. The response rate in theBrazilian group was 15.4% and in theSwedish group 36.5%.Results: Most respondents in both groups considered bone quality to be an important parameter for implant treatment outcome. Among Swedish specialists, bone quality, however, was considered to be of low relevance. The most popular method for assessing bone quality among Swedish specialists was the hand‐felt perception of drilling resistance followed by radiography. TheBrazilian specialists more often used peak insertion torque. Most respondents classified bone quality, and both groups used the classification proposed by Lekholm & Zarb (Tissue‐Integratedprosthesis: Osseointegration in Clinical Dentistry, 1985, Quintessence, Chicago) most frequently.Conclusion: Specialists in both countries considered bone quality to be an important parameter for implant treatment outcome, but there was no consensus neither on what bone quality means nor on how to assess bone quality.


  • Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography

    by A Al-Okshi, M Nilsson, A Petersson, M Wiese, C Lindh

    Objectives:To demonstrate the feasibility of GafChromic® XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units.Methods:The CBCT units used were Veraviewepocs 3De® (J Morita MFG Corp., Kyoto, Japan), ProMax® 3D (Planmeca, Helsinki, Finland) and NewTom VGi® (Quantitative Radiology, Verona, Italy). GafChromic XR-QA2 films were placed between the selected layers of the head and neck of a tissue-equivalent human skull (RANDO® phantom; The Phantom Laboratory, Salem, NY). The exposure parameters were set using the automatic exposure control function of the units. Depending on the availability, medium and smaller field of view (FOV) scanning modes were used. The effective dose was estimated using the 2007 International Commission on Rad...


  • Variation in costs of cone beam CT examinations among healthcare systems

    by H Christell, S Birch, M Hedesiu, K Horner, D Ivanauskaité, O Nackaerts, M Rohlin, C Lindh, The SEDENTEXCT consortium

    Objectives To analyse the costs of cone beam CT (CBCT) in different healthcare systems for patients with different clinical conditions. Methods Costs were calculated for CBCT performed in Cluj (Romania), Leuven (Belgium), Malmö (Sweden) and Vilnius (Lithuania) on patients with (i) a maxillary canine with eruption disturbance, (ii) an area with tooth loss prior to implant treatment or (iii) a lower wisdom tooth planned for removal. The costs were calculated using an approach based on the identification, measurement and valuation of all resources used in the delivery of the service that combined direct costs (capital equipment, accommodation, labour) with indirect costs (patients' and accompanying persons' time, “out of pocket” costs for examination fee and visits). Results The estimates for direct and indirect costs varied among the healthcare systems, being highest in Malmö and lowest in Leuven. Variation in direct costs was mainly owing to different capital costs for the CBCT equipment arising from diffe...


  • Open Access

    The use of visual assessment of dental radiographs for identifying women at risk of having osteoporosis: the OSTEODENT project

    by Christina Lindh, Keith Horner, Grethe Jonasson, Peter Olsson, Madeleine Rohlin, Reinhilde Jacobs, Kety Karayianni, Paul van der Stelt, Judith Adams, Elizabeth Marjanovic, et al.


    • 1 January 2008
      • Vol. 10  (1) , 36-43

    Observer performance based on marginal bone tissue visibility in Scanora panoramic radiography and posterior bitewing radiography.

    by Deimante Ivanauskaite, Christina Lindh, Madeleine Rohlin

    To evaluate image quality for marginal bone tissue assessment on panoramic radiographs taken with the Scanora dental programme and on posterior bitewing radiographs. Panoramic and bitewing radiographs were taken of 96 patients. Six observers rated marginal bone level visibility as excellent, acceptable, or unacceptable. Five observers assessed image quality for detection of vertical bone defects and furcation involvements as acceptable or unacceptable. Observer agreement was calculated as overall agreement and kappa values. Image quality of 36% of the panoramic and 6% of the bitewing sites was rated unacceptable for marginal bone loss assessment in the maxillae while 8% of the panoramic and bitewing sites in the mandible were unacceptable. For detecting vertical bone defects, image quality was unacceptable at one-third of the maxillary sites and 5% of the mandibular sites on the panoramic radiographs. Detection of furcation involvement was acceptable at most sites on both types of radiographs. Kappa values for intra- and inter-observer agreement were higher for panoramic than for bitewing radiographs. The kappa value for marginal bone loss assessment by several observers was moderate (0.45) for panorama and fair (0.28) for bitewing radiography. Corresponding kappa values for detection of vertical bone defects were substantial (0.62) and fair (0.25). Image quality as evaluated by visual grading analysis is adequate for marginal bone tissue assessment in mandibular molar and premolar regions and unacceptable in maxillary molar and premolar regions on panoramic radiographs taken with the Scanora technique compared to bitewing radiography.


    • 1 May 2007
      • Vol. 22  (2) , 289-300

    Efficacy of clinical methods to assess jawbone tissue prior to and during endosseous dental implant placement: a systematic literature review.

    by Rejane Faria Ribeiro-Rotta, Christina Lindh, Madeleine Rohlin

    To evaluate the evidence for the diagnostic accuracy of clinical methods to assess bone density, quantity, or quality prior to and during dental implant placement. A PubMed literature search with specific indexing terms and a hand search were made. From the retrieved titles and abstracts, 3 reviewers selected publications on the basis of predetermined inclusion and exclusion criteria. Data were extracted from the selected publications using a protocol. Original studies were interpreted with the aid of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. The literature search yielded 145 titles and abstracts, of which 71 were selected and read in full text. Seven studies were judged relevant. In 1 study, no method was presented as the test method. In 6 studies, the results of the test method were compared to those of a reference method. However, only 1 study presented the results in terms of percentage of correct diagnoses. In that study, the use of periapical radiography together with reference images yielded correct assessment of the trabecular pattern of the mandible in 3 categories in 58% of the sites. The kappa index of interobserver agreement was 0.35 and intraobserver agreement was 0.67. Corresponding kappa values for 4 classes of bone quality presented by Lekholm and Zarb were 0.33 and 0.43, respectively. No study examined the accuracy of the method originally described by Lekholm and Zarb. The evidence for the efficacy of clinical methods to assess jawbone tissue prior to and during endosseous dental implant placement is sparse. This emphasizes the need for studies that incorporate accepted methodologic criteria for diagnostic efficacy.