Ioannis Politopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ioannis Politopoulos has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Hoan Khac Pham
DEN/DANS/DM2S, CEA Saclay
2 shared publications- Sette Diop
SUPELEC, Laboratory of Signals and Systems (L2S), F 91192 Gif sur Yvette cedex, France
2 shared publications Cyril Feau
1 shared publicationDuc Chuan Vu
CEA, DEN, DM2S, SEMT, EMSI Gif‐sur‐Yvette France
1 shared publication- Duc Chuan Vu
CEA, DEN, DM2S, SEMT, EMSI; Gif-sur-Yvette F-91191 France
1 shared publication Jean‐Marc Martinez
Commissariat à l'énergie Atomique, DEN, DANS, DM2S Université Paris‐Saclay Gif‐sur‐Yvette France
1 shared publication
Latest Publications
- 17 August 2017
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 47 (1) , 219-235
Sensitivity analysis of pounding between adjacent structures
Summary: This article deals with sensitivity of the response of pounding buildings with respect to structural and earthquake excitation parameters. A comprehensive sensitivity analysis is carried out by means of Monte Carlo simulations of adjacent single degree of freedom impacting oscillators. This sensitivity analysis, based on Sobol's method, computes sensitivity indexes which provide a consistent measure of the relative importance of parameters such as the dimensionless main excitation frequency, the mass and frequency ratios of the structures, and the coefficient of restitution. Moreover, the influence of nonlinear behavior of the impacting structures is also considered. The consequences of pounding on the structures themselves are analyzed in terms of maximum force and nonlinear demand amplification compared with the case without pounding. As for the influence of pounding on the floor response spectra, the quantity of interest is the maximum impact impulse. The overall conclusions of this analysis are that the frequency ratio is the most important parameter as far as the maximum force and nonlinear demand are concerned. Regarding the maximum impact impulse, the mass and frequency ratios are, in general, the most influential parameters, the mass ratio being predominant for low frequencies of the oscillator of interest.
- 17 August 2017
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 47 (1) , 219-235
Sensitivity analysis of pounding between adjacent structures
Summary: This article deals with sensitivity of the response of pounding buildings with respect to structural and earthquake excitation parameters. A comprehensive sensitivity analysis is carried out by means of Monte Carlo simulations of adjacent single degree of freedom impacting oscillators. This sensitivity analysis, based on Sobol's method, computes sensitivity indexes which provide a consistent measure of the relative importance of parameters such as the dimensionless main excitation frequency, the mass and frequency ratios of the structures, and the coefficient of restitution. Moreover, the influence of nonlinear behavior of the impacting structures is also considered. The consequences of pounding on the structures themselves are analyzed in terms of maximum force and nonlinear demand amplification compared with the case without pounding. As for the influence of pounding on the floor response spectra, the quantity of interest is the maximum impact impulse. The overall conclusions of this analysis are that the frequency ratio is the most important parameter as far as the maximum force and nonlinear demand are concerned. Regarding the maximum impact impulse, the mass and frequency ratios are, in general, the most influential parameters, the mass ratio being predominant for low frequencies of the oscillator of interest.
- 30 May 2017
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 25 (1) , e2032
A new semi-active control based on nonlinear inhomogeneous optimal control for mixed base isolation
- 30 May 2017
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 25 (1) , e2032
A new semi-active control based on nonlinear inhomogeneous optimal control for mixed base isolation
- 21 April 2016
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 45 (12) , 2027-2037
Relaxation base seismic isolator
Summary: This paper deals with the use, for seismic applications, of a Maxwell element in parallel with a low damping isolator. The study of the properties of the frequency response function shows that this isolator is capable to reduce the base displacement of isolated structures with no considerable amplification of the non‐isolated modes. This is, also, confirmed by the floor response spectra under earthquake excitations. Hence, the previously mentioned isolator does not present the drawbacks met when base displacement is reduced by increasing damping. Moreover, it seems that its performance is comparable with that of more elaborated and expensive techniques combining passive and semi‐active devices. Copyright © 2016 John Wiley & Sons, Ltd.
- 21 April 2016
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 45 (12) , 2027-2037
Relaxation base seismic isolator
Summary: This paper deals with the use, for seismic applications, of a Maxwell element in parallel with a low damping isolator. The study of the properties of the frequency response function shows that this isolator is capable to reduce the base displacement of isolated structures with no considerable amplification of the non‐isolated modes. This is, also, confirmed by the floor response spectra under earthquake excitations. Hence, the previously mentioned isolator does not present the drawbacks met when base displacement is reduced by increasing damping. Moreover, it seems that its performance is comparable with that of more elaborated and expensive techniques combining passive and semi‐active devices. Copyright © 2016 John Wiley & Sons, Ltd.
- 23 February 2012
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 41 (3) , 587-592
Horizontal floor response spectra of base‐isolated buildings due to vertical excitation
SUMMARY: A mechanism of horizontal floor response spectra amplification in the vicinity of higher modes' frequencies is investigated. It is demonstrated, by means of a simple two‐degrees‐of‐freedom model, that in the case of unsymmetrical superstructure, such amplification may occur because of the coupling between vertical excitation and horizontal response of the non‐isolated modes. This phenomenon is further illustrated by the results of analyses of a model of a nuclear plant. Copyright © 2011 John Wiley & Sons, Ltd.
- 23 February 2012
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 41 (3) , 587-592
Horizontal floor response spectra of base‐isolated buildings due to vertical excitation
SUMMARY: A mechanism of horizontal floor response spectra amplification in the vicinity of higher modes' frequencies is investigated. It is demonstrated, by means of a simple two‐degrees‐of‐freedom model, that in the case of unsymmetrical superstructure, such amplification may occur because of the coupling between vertical excitation and horizontal response of the non‐isolated modes. This phenomenon is further illustrated by the results of analyses of a model of a nuclear plant. Copyright © 2011 John Wiley & Sons, Ltd.
- 31 December 2010
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 9 (4) , 1115-1135
Floor spectra of mixed base isolated structures
- 31 December 2010
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 9 (4) , 1115-1135
Floor spectra of mixed base isolated structures
- 5 October 2009
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 39 (3) , 325-342
Response of seismically isolated structures to rocking‐type excitations
In this paper, the origin of rocking‐type excitations and their effects on the response of base isolated structures are studied. In particular, the role of kinematic interaction in the determination of the rocking excitation is highlighted. The cases of surface foundations subjected to horizontally propagating waves, as well as of embedded foundations under vertically incident shear waves are examined. The validity of the kinematic interaction based on the rigid base mat assumption is discussed. It is shown that, in the case of classical horizontal isolation, rocking input may amplify significantly the response of the lower non‐isolated modes. The examination of full three‐dimensional isolation and active and semi‐active control methods demonstrates the efficacy of these methods to improve the performance of seismically isolated structures subjected to rocking excitations. Copyright © 2009 John Wiley & Sons, Ltd.
- 5 October 2009
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 39 (3) , 325-342
Response of seismically isolated structures to rocking‐type excitations
In this paper, the origin of rocking‐type excitations and their effects on the response of base isolated structures are studied. In particular, the role of kinematic interaction in the determination of the rocking excitation is highlighted. The cases of surface foundations subjected to horizontally propagating waves, as well as of embedded foundations under vertically incident shear waves are examined. The validity of the kinematic interaction based on the rigid base mat assumption is discussed. It is shown that, in the case of classical horizontal isolation, rocking input may amplify significantly the response of the lower non‐isolated modes. The examination of full three‐dimensional isolation and active and semi‐active control methods demonstrates the efficacy of these methods to improve the performance of seismically isolated structures subjected to rocking excitations. Copyright © 2009 John Wiley & Sons, Ltd.
- 11 December 2008
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 38 (8) , 989-1007
Sensitivity of seismically isolated structures
- 11 December 2008
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 38 (8) , 989-1007
Sensitivity of seismically isolated structures
- 1 October 2007
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 37 (3) , 447-465
A review of adverse effects of damping in seismic isolation
In this paper the question of possible adverse effects of damping in seismic isolation because of higher mode response is investigated by means of simple models with a few degrees of freedom (DOF). In particular the second mode response of a 2 DOF system is examined in detail for both viscous and hysteretic (e.g. friction or elastoplastic) damping devices. Qualitative and approximate quantitative estimates are obtained by neglecting the influence of the modal coupling terms, due to viscous damping or friction forces, on the first mode response. It is shown that additional viscous damping has a diminishing effect on base displacement, storey shear force and floor spectra values in the vicinity of the first mode resonance. However, a significant amplification of the floor spectra values near the higher mode frequencies may occur. In accordance with the results of previous works, compared with the viscous damping case, hysteretic damping amplifies moderately the first storey shear force and significantly the upper storeys shear force. It also results, in a much more pronounced amplification of the floor spectral values than viscous damping, in the vicinity of the higher eigenfrequencies. However, the higher modes' response is milder if a realistic velocity dependence of the friction coefficient is taken into account. Copyright © 2007 John Wiley & Sons, Ltd.
- 1 October 2007
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 37 (3) , 447-465
A review of adverse effects of damping in seismic isolation
In this paper the question of possible adverse effects of damping in seismic isolation because of higher mode response is investigated by means of simple models with a few degrees of freedom (DOF). In particular the second mode response of a 2 DOF system is examined in detail for both viscous and hysteretic (e.g. friction or elastoplastic) damping devices. Qualitative and approximate quantitative estimates are obtained by neglecting the influence of the modal coupling terms, due to viscous damping or friction forces, on the first mode response. It is shown that additional viscous damping has a diminishing effect on base displacement, storey shear force and floor spectra values in the vicinity of the first mode resonance. However, a significant amplification of the floor spectra values near the higher mode frequencies may occur. In accordance with the results of previous works, compared with the viscous damping case, hysteretic damping amplifies moderately the first storey shear force and significantly the upper storeys shear force. It also results, in a much more pronounced amplification of the floor spectral values than viscous damping, in the vicinity of the higher eigenfrequencies. However, the higher modes' response is milder if a realistic velocity dependence of the friction coefficient is taken into account. Copyright © 2007 John Wiley & Sons, Ltd.
- 2 January 2007
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 36 (8) , 975-993
Some aspects of floor spectra of 1DOF nonlinear primary structures
In this paper the influence of the nonlinear behaviour of the primary structure on floor spectra is investigated by means of simple models. The general trends of floor spectra for different types of nonlinear behaviour of one degree of freedom (1DOF) primary structure are shown and we point out their common futures and their differences. A special attention is given to the cases of elastoplastic and nonlinear elastic behaviours and methods to determine an equivalent linear oscillator are proposed. The properties (frequency and damping) of this equivalent linear oscillator are quite different from the properties of equivalent linear oscillators commonly considered in practice. In particular, in the case of elastoplastic behaviour, there is no frequency shift and damping is smaller than assumed by other methods commonly used. In the case of nonlinear elastic behaviour, the concept of an equivalent frequency which is a random variable is used. Finally, a design floor spectrum of primary structures, exhibiting energy dissipating nonlinear behaviour is proposed. Copyright © 2006 John Wiley & Sons, Ltd.
- 2 January 2007
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 36 (8) , 975-993
Some aspects of floor spectra of 1DOF nonlinear primary structures
In this paper the influence of the nonlinear behaviour of the primary structure on floor spectra is investigated by means of simple models. The general trends of floor spectra for different types of nonlinear behaviour of one degree of freedom (1DOF) primary structure are shown and we point out their common futures and their differences. A special attention is given to the cases of elastoplastic and nonlinear elastic behaviours and methods to determine an equivalent linear oscillator are proposed. The properties (frequency and damping) of this equivalent linear oscillator are quite different from the properties of equivalent linear oscillators commonly considered in practice. In particular, in the case of elastoplastic behaviour, there is no frequency shift and damping is smaller than assumed by other methods commonly used. In the case of nonlinear elastic behaviour, the concept of an equivalent frequency which is a random variable is used. Finally, a design floor spectrum of primary structures, exhibiting energy dissipating nonlinear behaviour is proposed. Copyright © 2006 John Wiley & Sons, Ltd.