Henryk Madura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henryk Madura has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Tomasz Sosnowski
Institute of Optoelectronics, Military University of Technology, 00-908 Warsaw, Poland
20 shared publications - Grzegorz Bieszczad
Institute of Optoelectronics, Military University of Technology, 00-908 Warsaw, Poland
14 shared publications Mariusz Kastek
7 shared publicationsM. Kastek
6 shared publications- Tadeusz Piatkowski
Military Univ. of Technology (Poland)
6 shared publications - Sławomir Gogler
Wojskowa Akademia Techniczna
4 shared publications
Latest Publications
- 7 December 2021
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 25 (4) , 67-76
Radiation Model of a Housing of Cooled Infrared Detector Array
The infrared camera detects infrared radiation from the observed objects, Its main element is the array of infrared detectors, which converts the received radiation into an electrical signal. The radiation sources recorded by the detector can be divided as useful, received from the observed scene, and useless received from such objects as the detector housing and lens elements. These unusable radiation sources have a significant impact on the design of the detector itself. The article presents a model of the detector housing and a quantitative analysis of the influence of various radiation sources on the effectiveness of radiation detection from the observed scene.
- 7 December 2021
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 25 (4) , 67-76
Radiation Model of a Housing of Cooled Infrared Detector Array
The infrared camera detects infrared radiation from the observed objects, Its main element is the array of infrared detectors, which converts the received radiation into an electrical signal. The radiation sources recorded by the detector can be divided as useful, received from the observed scene, and useless received from such objects as the detector housing and lens elements. These unusable radiation sources have a significant impact on the design of the detector itself. The article presents a model of the detector housing and a quantitative analysis of the influence of various radiation sources on the effectiveness of radiation detection from the observed scene.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 48, 141-144
Thermovision system for flying objects detection
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 48, 141-144
Thermovision system for flying objects detection
- 13 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9481, 948113-948113-11
Non-uniformity correction with temperature influence compensation in microbolometer detector
- 13 May 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9481, 948113-948113-11
Non-uniformity correction with temperature influence compensation in microbolometer detector
- Open Access
- 1 December 2014
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 21 (4) , 709-718
Non-Uniformity Correction in Microbolometer Array with Temperature Influence Compensation
In the article a non-uniformity correction method is presented which allows to compensate for the influence of detector’s temperature drift. For this purpose, dependency between output signal value and the temperature of the detector array was investigated. Additionally the influence of the temperature on the Offset and Gain coefficients was measured. Presented method utilizes estimated dependency between output signal of detectors and their temperature. In the presented method, the shutter is used for establishing signal reference. Thermoelectric cooler is used for changing the temperature of the detector array.
- 1 December 2014
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 21 (4) , 709-718
Open AccessNon-Uniformity Correction in Microbolometer Array with Temperature Influence Compensation
In the article a non-uniformity correction method is presented which allows to compensate for the influence of detector’s temperature drift. For this purpose, dependency between output signal value and the temperature of the detector array was investigated. Additionally the influence of the temperature on the Offset and Gain coefficients was measured. Presented method utilizes estimated dependency between output signal of detectors and their temperature. In the presented method, the shutter is used for establishing signal reference. Thermoelectric cooler is used for changing the temperature of the detector array.
- 24 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8541, 85411J
Determining the responsivity of microbolometer FPA using variable optical aperture stop
Contemporary infrared detector arrays suffers from technological imprecision which causes that the response to uniform radiation results in nonuniform image with superimposed fixed pattern noise (FPN). In order to compensate this noise there is a need to evaluate detectors characteristics like responsivity and offset of every detector in array. In article the method of determining the responsivity of detectors in a microbolometer array is described. In the method geometrical and optical parameters of the detector array and the measurement system are taken into account. A special test bench was constructed and is consisting of: two precise surface black bodies, aperture limiter, an electronic interface for data acquisition and software for measurement and correction of results with optical parameters of the measuring stand taken into account. Constructed aperture limiter enables evaluation of optical paths in measurement stand with equivalent relative aperture F# from 0.5 to 16.1 In order to evaluate the impact of optical path to radiation distribution in the measurement system, special radiation model was elaborated and evaluated in Zemax software. Incident radiation intensity distribution on the detector surface was calculated using Monte-Carlo method for various parameters of the optical path in the measurement system. Calculated radiation maps were used to compensate radiation intensity nonuniformity of optical measurement system giving more precise responsivity evaluation of detector array parameters. The obtained values of voltage responsivity of the detectors in the array, can be used in algorithms like nonuniformity correction and radiometric calibration of the infrared camera. In article results of responsivity evaluation is presented for microbolometer infrared arrays from ULIS company (France).
- 24 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8541, 85411J
Determining the responsivity of microbolometer FPA using variable optical aperture stop
Contemporary infrared detector arrays suffers from technological imprecision which causes that the response to uniform radiation results in nonuniform image with superimposed fixed pattern noise (FPN). In order to compensate this noise there is a need to evaluate detectors characteristics like responsivity and offset of every detector in array. In article the method of determining the responsivity of detectors in a microbolometer array is described. In the method geometrical and optical parameters of the detector array and the measurement system are taken into account. A special test bench was constructed and is consisting of: two precise surface black bodies, aperture limiter, an electronic interface for data acquisition and software for measurement and correction of results with optical parameters of the measuring stand taken into account. Constructed aperture limiter enables evaluation of optical paths in measurement stand with equivalent relative aperture F# from 0.5 to 16.1 In order to evaluate the impact of optical path to radiation distribution in the measurement system, special radiation model was elaborated and evaluated in Zemax software. Incident radiation intensity distribution on the detector surface was calculated using Monte-Carlo method for various parameters of the optical path in the measurement system. Calculated radiation maps were used to compensate radiation intensity nonuniformity of optical measurement system giving more precise responsivity evaluation of detector array parameters. The obtained values of voltage responsivity of the detectors in the array, can be used in algorithms like nonuniformity correction and radiometric calibration of the infrared camera. In article results of responsivity evaluation is presented for microbolometer infrared arrays from ULIS company (France).
- 9 June 2011
- Published by SPIE-Intl Soc Optical Eng
- p. 81933W-81933W-10
Electro-optical system for gunshot detection: analysis, concept, and performance
The paper discusses technical possibilities to build an effective electro-optical sensor unit for sniper detection using infrared cameras. This unit, comprising of thermal and daylight cameras, can operate as a standalone device but its primary application is a multi-sensor sniper and shot detection system. At first, the analysis was presented of three distinguished phases of sniper activity: before, during and after the shot. On the basis of experimental data the parameters defining the relevant sniper signatures were determined which are essential in assessing the capability of infrared camera to detect sniper activity. A sniper body and muzzle flash were analyzed as targets and the descriptions of phenomena which make it possible to detect sniper activities in infrared spectra as well as analysis of physical limitations were performed. The analyzed infrared systems were simulated using NVTherm software. The calculations for several cameras, equipped with different lenses and detector types were performed. The simulation of detection ranges was performed for the selected scenarios of sniper detection tasks. After the analysis of simulation results, the technical specifications of infrared sniper detection system were discussed, required to provide assumed detection range. Finally the infrared camera setup was proposed which can detected sniper from 1000 meters range.
- 9 June 2011
- Published by SPIE-Intl Soc Optical Eng
- p. 81933W-81933W-10
Electro-optical system for gunshot detection: analysis, concept, and performance
The paper discusses technical possibilities to build an effective electro-optical sensor unit for sniper detection using infrared cameras. This unit, comprising of thermal and daylight cameras, can operate as a standalone device but its primary application is a multi-sensor sniper and shot detection system. At first, the analysis was presented of three distinguished phases of sniper activity: before, during and after the shot. On the basis of experimental data the parameters defining the relevant sniper signatures were determined which are essential in assessing the capability of infrared camera to detect sniper activity. A sniper body and muzzle flash were analyzed as targets and the descriptions of phenomena which make it possible to detect sniper activities in infrared spectra as well as analysis of physical limitations were performed. The analyzed infrared systems were simulated using NVTherm software. The calculations for several cameras, equipped with different lenses and detector types were performed. The simulation of detection ranges was performed for the selected scenarios of sniper detection tasks. After the analysis of simulation results, the technical specifications of infrared sniper detection system were discussed, required to provide assumed detection range. Finally the infrared camera setup was proposed which can detected sniper from 1000 meters range.