TKTae-Soon Kwon

Tae-Soon Kwon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tae-Soon Kwon has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • B. J. Yun

    Korea Atomic Energy Research Institute, Daejeon, Korea

    1 shared publication
  • C.-H. Song

    Korea Atomic Energy Research Institute, Daejeon, Korea

    1 shared publication
  • Choengryul Choi

    Elsoltec Inc., Yongin, Republic of Korea

    1 shared publication
  • Dae Kyung Choi

    ELSOLTEC, 1401-2, 184 Jungbu-daero, Giheung-gu, Yougin-si 17095, Gyeonggi-do, Republic of Korea

    1 shared publication
  • Dong-Jin Euh

    Atomic Energy Research Institute, 111, Daedeok-daero 989 beon-gil, Yuseong-gu, Daejeon 34057, Republic of Korea

    1 shared publication
  • Dongjin Euh

    Thermal Hydraulic Safety Research Division, Korea Atomic Energy Research Institute, Daedeok-daero 1045, Yuseong, Daejeon 305-353, Korea; Advanced Nuclear System Engineering Department, University of Science and Technology, Gajungro 217, Yuseong-Gu, Daejeon 305-350, Republic of Korea

    1 shared publication

Latest Publications

  • Open Access

    Steam-Jet Evaluation for Predicting Leakage Behavior and Interpretation of Experimental Verification

    by Dae Kyung Choi, Won Man Park, Woo-Shik Kim, Dong-Jin Euh, Tae-Soon Kwon, Choengryul Choi

    Owing to pipe thinning, fatigue damage, and aging, pipes, valves, and devices installed in the primary and secondary systems of nuclear power plants may leak high-temperature/high-pressure reactor coolant. Thus, a system must be developed to determine if the leakage is exceeding the operating limit of the nuclear power plant, thereby mitigating any loss of life or economic loss in such cases. In this study, a validated numerical analysis method was established to initially simulate the leakage behavior and subsequently to evaluate the small amount of leakage in the compartment. For this purpose, a vapor-jet collision test in the compartment and a vapor-jet test in the pipe were performed; numerical analysis was conducted, and comparative analysis was performed to verify the validity of the established method. The evaluation results suggested that the proposed numerical analysis method could optimally simulate the flow characteristics of the steam jet. Notably, compared to the existing evaluation method, the proposed approach simulated a more detailed behavior of the jet formed at the leakage point. In future research, the results of this study (data) will be used to inform the design of the second phase of the leak-capture system and will be served as the foundation for a performance-optimization study on the capture system.


  • Experimental identification for flow distribution inside APR+ reactor vessel and direction of internal structure design improvement

    by Dongjin Euh, Kihwan Kim, Incheol Chu, Haeseob Choi, Taesoon Kwon

    A test program to quantify the reactor flow distribution has been performed using a test facility, named ACOP, having a 1/5 length scale referring to the APR+ reactor design. The flow characteristics of the prototype plant could be preserved by designing the test facility by adopting a linear reduced scaling principle. An Euler number is considered as a primary dimensionless parameter, which was preserved with a 1/41.0 Reynolds number scaling ratio based on the balanced flow conditions. The important measuring parameters are the core inlet flow, outlet pressure distribution, and sectional pressure drops along the major flow path inside the reactor vessel as well as static pressure and temperature at the vessel and boundary legs. The reactor flow distribution is identified by a series of three reactor flow balancing conditions: (1) balanced cold leg flow condition (2) 5% unbalanced cold leg flow condition, and (3) extreme unbalanced flow condition under the assumption of a single pump failure. This paper describes the design features for the test facility and the measuring method, and summarizes the reactor flow and pressure characteristics by ensemble averaging for each group of tests.


  • Scaling Methodology for the Direct ECC Bypass During LBLOCA Reflood Phase With Direct Vessel Injection System: Its Development and Validation

    by H. K. Cho, B. J. Yun, T. S. Kwon, C.-H. Song, G. C. Park

    From the two dimensional two-fluid model a new scaling methodology, named the “modified linear scaling”, is suggested for the scientific design of a scaled-down experimental facility and data analysis of the direct ECC bypass under LBLOCA reflood phase. The characteristics of the scaling law are its velocity is scaled by a Wallis-type parameter and the aspect ratio of experimental facility is preserved with that of prototype. For the experimental validation of the proposed scaling law, the air-water tests for direct ECC bypass were performed in the 1/4.0 and 1/7.3 scaled UPTF downcomer test section. The obtained data are compared with those of UPTF Test21-D. It is found that the modified linear scaling methodology is appropriate for the preservation of multi-dimensional flow phenomena in downcomer annulus, such as direct ECC bypass.