Laurent Barbé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Laurent Barbé has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bernard Bayle
University of Strasbourg, CNRS, INSERM
5 shared publications - Michel de Mathelin
University of Strasbourg, CNRS
4 shared publications A. Gangi
Radiology Department B, University Hospitals of Strasbourg, Strasbourg 67091, France
2 shared publications- Olivier Piccin
University of Strasbourg, Strasbourg, France
2 shared publications - Jacques Gangloff
LSIIT Laboratory, University of Strasbourg & CNRS , Pôle API, BP 10413, F 67412 , Illkirch Cedex , France
1 shared publication Michel De Mathelin
1 shared publication
Latest Publications
- 19 May 2009
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 28 (9) , 1154-1168
A Force Feedback Teleoperated Needle Insertion Device for Percutaneous Procedures
A novel robotized tool for percutaneous interventions under CT-scanner guidance is presented in this paper. This teleoperated compact robotic device can be used as an end-effector for an image-guided positioning robot. It is fully compatible with computed tomography constraints. In particular, it is able to manipulate needles that are longer than the overall height of its body. This novel device mimics the manual gesture performed by the physician by grasping and re-grasping the needle. This operating principle enables direct force measurement on the inserted surgical needle and allows efficient teleoperation with force feedback. In the paper, the specifications of this needle driver are presented and the proposed design is explained. Experiments conducted on swine under operating conditions were performed in order to validate both the concept and the design of the proposed insertion device in the context of teleoperated needle insertions with force feedback.
- 19 May 2009
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 28 (9) , 1154-1168
A Force Feedback Teleoperated Needle Insertion Device for Percutaneous Procedures
A novel robotized tool for percutaneous interventions under CT-scanner guidance is presented in this paper. This teleoperated compact robotic device can be used as an end-effector for an image-guided positioning robot. It is fully compatible with computed tomography constraints. In particular, it is able to manipulate needles that are longer than the overall height of its body. This novel device mimics the manual gesture performed by the physician by grasping and re-grasping the needle. This operating principle enables direct force measurement on the inserted surgical needle and allows efficient teleoperation with force feedback. In the paper, the specifications of this needle driver are presented and the proposed design is explained. Experiments conducted on swine under operating conditions were performed in order to validate both the concept and the design of the proposed insertion device in the context of teleoperated needle insertions with force feedback.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 485-490
Design and Evaluation of a Linear Haptic Device
The commercial development of haptic devices is very promising. Existing systems are often 6-degree-of-freedom mechanisms equipped with a stylus that acts as a tool. They exhibit force feedback for 3 or 6 degrees of freedom of their end-effector, depending on whether only forces or both forces and torques are rendered. Some planar devices are also used but oddly, one-degree-of-freedom linear haptic devices are quite rare. This lack can probably be explained by the necessary mechanical transformations that are required to achieve linear motions with rotary motors. In this paper, we review several possible structures and present the design of a new one-degree-of-freedom linear haptic device with a limited number of joints and a compact design, compatible with rotary actuation. We evaluate this device in the telemanipulation context.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 485-490
Design and Evaluation of a Linear Haptic Device
The commercial development of haptic devices is very promising. Existing systems are often 6-degree-of-freedom mechanisms equipped with a stylus that acts as a tool. They exhibit force feedback for 3 or 6 degrees of freedom of their end-effector, depending on whether only forces or both forces and torques are rendered. Some planar devices are also used but oddly, one-degree-of-freedom linear haptic devices are quite rare. This lack can probably be explained by the necessary mechanical transformations that are required to achieve linear motions with rotary motors. In this paper, we review several possible structures and present the design of a new one-degree-of-freedom linear haptic device with a limited number of joints and a compact design, compatible with rotary actuation. We evaluate this device in the telemanipulation context.
- 1 January 2006
- Vol. 119, 43-5
Online robust model estimation during in vivo needle insertions.
Soft tissue modeling is of key importance in medical robotics and simulation. In the case of percutaneous operations, a fine model of layers transitions and target tissues is required. However, the nature and the variety of these tissues is such that this problem is extremely complex. In this article, we propose a method to estimate the interaction between in vivo tissues and a surgical needle. The online robust estimation of a varying parameters model is achieved during an insertion in standard operating conditions.
- 1 January 2006
- Vol. 119, 43-5
Online robust model estimation during in vivo needle insertions.
Soft tissue modeling is of key importance in medical robotics and simulation. In the case of percutaneous operations, a fine model of layers transitions and target tissues is required. However, the nature and the variety of these tissues is such that this problem is extremely complex. In this article, we propose a method to estimate the interaction between in vivo tissues and a surgical needle. The online robust estimation of a varying parameters model is achieved during an insertion in standard operating conditions.
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (15) , 482-487
TOWARDS THE AUTOTUNING OF FORCE-FEEDBACK TELEOPERATORS
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (15) , 482-487
TOWARDS THE AUTOTUNING OF FORCE-FEEDBACK TELEOPERATORS
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (18) , 129-134
NEEDLE INSERTIONS MODELLING : IDENTIFIABILITY AND LIMITATIONS
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (18) , 129-134
NEEDLE INSERTIONS MODELLING : IDENTIFIABILITY AND LIMITATIONS