Kazuo Funaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazuo Funaki has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Masataka Iwakuma
Kyushu University, Fukuoka, Japan
7 shared publications K. Yamafuji
2 shared publications- Kazuhiro Kajikawa
Department of Electrical Engineering, Sanyo-Onoda City University, Yamaguchi, Japan
2 shared publications M. Iwakuma
Research Institute of Superconductor Science and Systems, Kyushu University, 744 Moto-oka, Nishi-ku, Fukuoka 819-0395, Japan
2 shared publicationsM. Takeo
2 shared publicationsS. Yoshida
2 shared publications
Latest Publications
- 4 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 4700804
Transport AC Loss Properties of a Bi-2223 Superconducting Coil From 0.1 Hz to 10 Hz
We propose a method to evaluate transport AC losses in Bi-2223 superconducting coils by integrating the local external-field losses of the stacked taped wires over the coil's windings. We measured the transport AC losses of a 16 double-pancake coil of twisted Bi-2223 Ag-sheathed tapes, in the frequency range from 0.1 to 10 Hz at liquid nitrogen temperature. We also measured the external-field losses of short specimens of 6-stack Bi-2223 wires both in perpendicular and parallel field configurations through a saddle-shaped pickup coil method. The external losses are mainly due to hysteresis losses in the superconducting filaments and coupling losses among the filaments. The local external-field loss in the test coil is approximately calculated as the sum of perpendicular- and parallel-field losses of the short specimen. In the calculation, geometrical effects because of the neighboring turns in the coil are also considered, in addition to the magnitude and direction distributions of the local magnetic field. We compared the numerically evaluated external-field losses to the measured transport AC losses, and discussed the applicability of the proposed method.
- 4 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 4700804
Transport AC Loss Properties of a Bi-2223 Superconducting Coil From 0.1 Hz to 10 Hz
We propose a method to evaluate transport AC losses in Bi-2223 superconducting coils by integrating the local external-field losses of the stacked taped wires over the coil's windings. We measured the transport AC losses of a 16 double-pancake coil of twisted Bi-2223 Ag-sheathed tapes, in the frequency range from 0.1 to 10 Hz at liquid nitrogen temperature. We also measured the external-field losses of short specimens of 6-stack Bi-2223 wires both in perpendicular and parallel field configurations through a saddle-shaped pickup coil method. The external losses are mainly due to hysteresis losses in the superconducting filaments and coupling losses among the filaments. The local external-field loss in the test coil is approximately calculated as the sum of perpendicular- and parallel-field losses of the short specimen. In the calculation, geometrical effects because of the neighboring turns in the coil are also considered, in addition to the magnitude and direction distributions of the local magnetic field. We compared the numerically evaluated external-field losses to the measured transport AC losses, and discussed the applicability of the proposed method.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 3053-3056
Development of Low-AC-Loss Bi-2223 Superconducting Multifilamentary Wires
We have been designing and developing advanced Ag-sheathed Bi-2223 multifilamentary wires for the future applications to superconducting transformers of electric rolling stocks. Trial wires were twisted without remarkable degradation in the transport property for suppressing AC losses in a perpendicular magnetic field configuration. The AC losses were measured by a saddle-shaped pickup coil in a wide range of frequency up to a commercial frequency. The experimental results show that the AC loss per cycle has linear frequency dependence in a region of the practical amplitude of AC magnetic field for the transformers, where the excess loss may come from an electromagnetic coupling between the filaments. The hysteresis loss evaluated as a low frequency limit of the AC loss was also reduced with the decrease in the twist pitch, which may be considered as a similar effect to the so-called ldquotwist effectrdquo observed in in-situ Nb3Sn wires.
- 30 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 3053-3056
Development of Low-AC-Loss Bi-2223 Superconducting Multifilamentary Wires
We have been designing and developing advanced Ag-sheathed Bi-2223 multifilamentary wires for the future applications to superconducting transformers of electric rolling stocks. Trial wires were twisted without remarkable degradation in the transport property for suppressing AC losses in a perpendicular magnetic field configuration. The AC losses were measured by a saddle-shaped pickup coil in a wide range of frequency up to a commercial frequency. The experimental results show that the AC loss per cycle has linear frequency dependence in a region of the practical amplitude of AC magnetic field for the transformers, where the excess loss may come from an electromagnetic coupling between the filaments. The hysteresis loss evaluated as a low frequency limit of the AC loss was also reduced with the decrease in the twist pitch, which may be considered as a similar effect to the so-called ldquotwist effectrdquo observed in in-situ Nb3Sn wires.
- 15 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1723-1726
Basic AC loss properties of IBAD/CVD-YBCO tapes for pancake-type coils
- 15 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1723-1726
Basic AC loss properties of IBAD/CVD-YBCO tapes for pancake-type coils
- 30 May 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1787-1791
A round robin test for pre-standardization of a saddle-shaped pickup coil method to measure AC losses in Bi-2223 Ag-sheathed tapes
- 30 May 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1787-1791
A round robin test for pre-standardization of a saddle-shaped pickup coil method to measure AC losses in Bi-2223 Ag-sheathed tapes
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1927-1930
Tests of Superconducting Traction Transformer for Railway Rolling Stock
We have been developing a lightweight and high-efficiency superconducting traction transformer for railway rolling stock. We designed and fabricated a prototype superconducting traction transformer of a floor-mount type for Shinkansen rolling stock. In this study, we present test results such as type test, system test and vibration test. We performed the type test in accordance with JIS, E5007. In this test, we measured the basic electrical characteristics. In the system test, we tested the transformer with a dynamic simulator for rolling stock, as a converter connected at secondary winding, and verified the operating characteristics. We performed vibration tests in accordance with JIS, E4031, vibrating the transformer on a shaking table with three-dimensional movement. As a result, we could verify that the transformer satisfied the requirement almost exactly as initially planned.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1927-1930
Tests of Superconducting Traction Transformer for Railway Rolling Stock
We have been developing a lightweight and high-efficiency superconducting traction transformer for railway rolling stock. We designed and fabricated a prototype superconducting traction transformer of a floor-mount type for Shinkansen rolling stock. In this study, we present test results such as type test, system test and vibration test. We performed the type test in accordance with JIS, E5007. In this test, we measured the basic electrical characteristics. In the system test, we tested the transformer with a dynamic simulator for rolling stock, as a converter connected at secondary winding, and verified the operating characteristics. We performed vibration tests in accordance with JIS, E4031, vibrating the transformer on a shaking table with three-dimensional movement. As a result, we could verify that the transformer satisfied the requirement almost exactly as initially planned.
- 15 May 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 613 (1) , 473
1 ATM subcooled liquid nitrogen cryogenic system with GM-refrigerator for a HTS power transformer
A subcooled liquid nitrogen cryogenic system with GM-refrigerators was developed. The system was operated successfully in a commercial distribution power grid for three consecutive weeks without additional liquid nitrogen supply. The system consists of two main units. One is a HTS transformer unit and the HTS transformer is installed in a G-FRP cryostat. The other one is a pump unit. The pump unit has a liquid nitrogen pump and two GM-refrigerators of 290 W at 64 K for 50 Hz operation in a stainless steel dewar. The refrigerator cold heads are immersed in liquid nitrogen and produce directly subcooled liquid nitrogen in the pump unit. Those two units are connected by transfer-tubes and 1 atmosphere (0.1 MPa) subcooled liquid nitrogen is circulated through the system. In the field test, the refrigerators were operated at 60 Hz and it took 12 hours to cool the transformer down to 70 K and 26 hours to 66 K. The refrigerator cold heads were controlled not to be below 64 K during operation. In spite of a heat generation by the HTS transformer, the subcooled liquid nitrogen temperature in the HTS transformer unit was kept lower than 68 K.
- 15 May 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 613 (1) , 473
1 ATM subcooled liquid nitrogen cryogenic system with GM-refrigerator for a HTS power transformer
A subcooled liquid nitrogen cryogenic system with GM-refrigerators was developed. The system was operated successfully in a commercial distribution power grid for three consecutive weeks without additional liquid nitrogen supply. The system consists of two main units. One is a HTS transformer unit and the HTS transformer is installed in a G-FRP cryostat. The other one is a pump unit. The pump unit has a liquid nitrogen pump and two GM-refrigerators of 290 W at 64 K for 50 Hz operation in a stainless steel dewar. The refrigerator cold heads are immersed in liquid nitrogen and produce directly subcooled liquid nitrogen in the pump unit. Those two units are connected by transfer-tubes and 1 atmosphere (0.1 MPa) subcooled liquid nitrogen is circulated through the system. In the field test, the refrigerators were operated at 60 Hz and it took 12 hours to cool the transformer down to 70 K and 26 hours to 66 K. The refrigerator cold heads were controlled not to be below 64 K during operation. In spite of a heat generation by the HTS transformer, the subcooled liquid nitrogen temperature in the HTS transformer unit was kept lower than 68 K.
- 1 June 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 9 (2) , 746-749
Influences of geometrical configuration on AC loss measurement with pickup-coil method
- 1 June 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 9 (2) , 746-749
Influences of geometrical configuration on AC loss measurement with pickup-coil method
- 1 July 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 32 (4) , 2671-2674
Development of 2 kA high-temperature-superconductor current lead system for AC applications
- 1 July 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 32 (4) , 2671-2674
Development of 2 kA high-temperature-superconductor current lead system for AC applications
- 1 March 1991
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 27 (2) , 2080-2083
Quench protection of superconducting transformers
- 1 March 1991
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 27 (2) , 2080-2083
Quench protection of superconducting transformers