Philip R. Tiller
Philip R. Tiller has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Leslie A. Romanyshyn
Merck Research Laboratories
3 shared publicationsJose Castro‐Perez
Waters Corporation, Milford, MA 01757, USA
2 shared publicationsSean Yu
Merck Research Laboratories, West Point, PA 19486, USA
2 shared publicationsThomas A. Baillie
Merck Research Laboratories, West Point, PA 19486, USA
2 shared publicationsIan S. Mcintosh
Merck Research Laboratories, West Point, PA 19486, USA
1 shared publicationKerry L. Fillgrove
Drug Metabolism and Pharmacokinetics, Merck Research Laboratories, West Point, PA 19486, USA
1 shared publication
Latest Publications
- 13 October 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (22) , 3510-3516
Fractional mass filtering as a means to assess circulating metabolites in early human clinical studies
Recent changes in the regulatory environment have led to a need for new methods to assess circulating human drug metabolites in early clinical studies with respect to their potential toxicological impact. The specific goals of such studies are to determine if the metabolites present in human plasma following administration of a drug candidate also are observed in plasma from the animal studies employed for preclinical toxicological evaluation, and to estimate corresponding exposure margins (animal:human) for the major metabolites. Until recently, the accepted best practice for the characterization of circulating drug metabolites utilized liquid chromatography/tandem mass spectrometry (LC/MS/MS)‐based methodologies, in conjunction with authentic chemical standards, for the detection and quantitative analyses of metabolites predicted from both animal studies and experiments with human liver preparations in vitro . While this approach is satisfactory for anticipated biotransformation products, metabolites that were not expected to circulate in human plasma frequently escape detection. Current accurate mass instruments enable the use of the technique of fractional mass filtering to detect both expected and unexpected metabolites in a rapid, less resource‐intensive and more robust manner. Application of this technology to several clinical development programs at Merck Research Laboratories has demonstrated the value of fractional mass filtering in the assessment of circulating drug metabolites in early clinical trials. Copyright © 2008 John Wiley & Sons, Ltd.
- 13 October 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (22) , 3510-3516
Fractional mass filtering as a means to assess circulating metabolites in early human clinical studies
Recent changes in the regulatory environment have led to a need for new methods to assess circulating human drug metabolites in early clinical studies with respect to their potential toxicological impact. The specific goals of such studies are to determine if the metabolites present in human plasma following administration of a drug candidate also are observed in plasma from the animal studies employed for preclinical toxicological evaluation, and to estimate corresponding exposure margins (animal:human) for the major metabolites. Until recently, the accepted best practice for the characterization of circulating drug metabolites utilized liquid chromatography/tandem mass spectrometry (LC/MS/MS)‐based methodologies, in conjunction with authentic chemical standards, for the detection and quantitative analyses of metabolites predicted from both animal studies and experiments with human liver preparations in vitro . While this approach is satisfactory for anticipated biotransformation products, metabolites that were not expected to circulate in human plasma frequently escape detection. Current accurate mass instruments enable the use of the technique of fractional mass filtering to detect both expected and unexpected metabolites in a rapid, less resource‐intensive and more robust manner. Application of this technology to several clinical development programs at Merck Research Laboratories has demonstrated the value of fractional mass filtering in the assessment of circulating drug metabolites in early clinical trials. Copyright © 2008 John Wiley & Sons, Ltd.
- 26 March 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (7) , 1053-1061
High‐throughput, accurate mass liquid chromatography/tandem mass spectrometry on a quadrupole time‐of‐flight system as a ‘first‐line’ approach for metabolite identification studies
Throughput for drug metabolite identification studies has been increased significantly by the combined use of accurate mass liquid chromatography/tandem mass spectrometry (LC/MS/MS) data on a quadrupole time‐of‐flight (QTOF) system and targeted data analysis procedures. Employed in concert, these tools have led to the implementation of a semi‐automated high‐throughput metabolite identification strategy that has been incorporated successfully into lead optimization efforts in drug discovery. The availability of elemental composition data on precursor and all fragment ions in each spectrum has greatly enhanced confidence in ion structure assignments, while computer‐based algorithms for defining sites of biotransformation based upon mass shifts of diagnostic fragment ions have facilitated identification of positions of metabolic transformation in drug candidates. Adoption of this technology as the ‘first‐line’ approach for in vitro metabolite profiling has resulted in the analysis of as many as 21 new chemical entities on one day from diverse structural classes and therapeutic programs. Copyright © 2008 John Wiley & Sons, Ltd.
- 26 March 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (7) , 1053-1061
High‐throughput, accurate mass liquid chromatography/tandem mass spectrometry on a quadrupole time‐of‐flight system as a ‘first‐line’ approach for metabolite identification studies
Throughput for drug metabolite identification studies has been increased significantly by the combined use of accurate mass liquid chromatography/tandem mass spectrometry (LC/MS/MS) data on a quadrupole time‐of‐flight (QTOF) system and targeted data analysis procedures. Employed in concert, these tools have led to the implementation of a semi‐automated high‐throughput metabolite identification strategy that has been incorporated successfully into lead optimization efforts in drug discovery. The availability of elemental composition data on precursor and all fragment ions in each spectrum has greatly enhanced confidence in ion structure assignments, while computer‐based algorithms for defining sites of biotransformation based upon mass shifts of diagnostic fragment ions have facilitated identification of positions of metabolic transformation in drug candidates. Adoption of this technology as the ‘first‐line’ approach for in vitro metabolite profiling has resulted in the analysis of as many as 21 new chemical entities on one day from diverse structural classes and therapeutic programs. Copyright © 2008 John Wiley & Sons, Ltd.
- 1 November 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 377 (5) , 788-802
Fast LC/MS in the analysis of small molecules
Liquid chromatography-mass spectrometry (LC/MS) has become one of the most widely used analytical techniques in both qualitative and quantitative analysis of small molecules. Recently, with the increasing demand for ever-higher sample throughput, the use of faster chromatographic separations has become popular, along with other LC/MS methods that decrease analytical cycle-time. The burgeoning use of LC/MS has meant that the primary expertise of many practitioners today is not in the field of LC/MS, which has been facilitated by the ease-of-use of modern LC/MS systems. An examination of the current state of the literature, relating to "fast LC/MS", should serve well to those new to LC/MS, and should help them in the development of fast LC/MS methods that are effective in terms of both the chromatography and the utilization of the mass spectrometer. This review paper focuses on fast LC/MS analyses of small molecules that have been reported in peer-reviewed publications.
- 1 November 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 377 (5) , 788-802
Fast LC/MS in the analysis of small molecules
Liquid chromatography-mass spectrometry (LC/MS) has become one of the most widely used analytical techniques in both qualitative and quantitative analysis of small molecules. Recently, with the increasing demand for ever-higher sample throughput, the use of faster chromatographic separations has become popular, along with other LC/MS methods that decrease analytical cycle-time. The burgeoning use of LC/MS has meant that the primary expertise of many practitioners today is not in the field of LC/MS, which has been facilitated by the ease-of-use of modern LC/MS systems. An examination of the current state of the literature, relating to "fast LC/MS", should serve well to those new to LC/MS, and should help them in the development of fast LC/MS methods that are effective in terms of both the chromatography and the utilization of the mass spectrometer. This review paper focuses on fast LC/MS analyses of small molecules that have been reported in peer-reviewed publications.
- 16 May 2002
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (12) , 1225-1231
Liquid chromatography/tandem mass spectrometric quantification with metabolite screening as a strategy to enhance the early drug discovery process
Throughput for early discovery drug metabolism studies can be increased with the concomitant acquisition of metabolite screening information and quantitative analysis using ultra‐fast gradient chromatographic methods. Typical ultra‐fast high‐performance liquid chromatography (HPLC) parameters used during early discovery pharmacokinetic (PK) studies, for example, employ full‐linear gradients over 1–2 min at very high flow rates (1.5–2 mL/min) on very short HPLC columns (2 × 20 mm). These conditions increase sample throughput by reducing analytical run time without sacrificing chromatographic integrity and may be used to analyze samples generated from a variety of in vitro and in vivo studies. This approach allows acquisition of more information about a lead candidate while maintaining rapid analytical turn‐around time. Some examples of this approach are discussed in further detail. Copyright © 2002 John Wiley & Sons, Ltd.
- 16 May 2002
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (12) , 1225-1231
Liquid chromatography/tandem mass spectrometric quantification with metabolite screening as a strategy to enhance the early drug discovery process
Throughput for early discovery drug metabolism studies can be increased with the concomitant acquisition of metabolite screening information and quantitative analysis using ultra‐fast gradient chromatographic methods. Typical ultra‐fast high‐performance liquid chromatography (HPLC) parameters used during early discovery pharmacokinetic (PK) studies, for example, employ full‐linear gradients over 1–2 min at very high flow rates (1.5–2 mL/min) on very short HPLC columns (2 × 20 mm). These conditions increase sample throughput by reducing analytical run time without sacrificing chromatographic integrity and may be used to analyze samples generated from a variety of in vitro and in vivo studies. This approach allows acquisition of more information about a lead candidate while maintaining rapid analytical turn‐around time. Some examples of this approach are discussed in further detail. Copyright © 2002 John Wiley & Sons, Ltd.
- 13 December 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 92-98
Implications of matrix effects in ultra‐fast gradient or fast isocratic liquid chromatography with mass spectrometry in drug discovery
In the analysis of biological samples it is important to reduce the risk of interferences from the matrix itself, other analytes, the dosing vehicle (commonly PEG), and from the MS/MS transitions used for the analysis. Rapid analysis is essential for drug discovery, and even though the requirements for separation may be minimized for speed, the integrity of the analysis is still dependent on the separation. This paper focuses on the potential for interferences from various endogenous and exogenous matrix components commonly encountered in quantitation of analytes and their metabolites from biological matrices. We demonstrate that neither high organic isocratic nor ballistic gradient ultra‐fast HPLC show a clearly defined advantage in regards to complex biological matrices. The critical factor in the resolution of matrix interferences still remains in sample preparation. Copyright © 2001 John Wiley & Sons, Ltd.
- 13 December 2001
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 92-98
Implications of matrix effects in ultra‐fast gradient or fast isocratic liquid chromatography with mass spectrometry in drug discovery
In the analysis of biological samples it is important to reduce the risk of interferences from the matrix itself, other analytes, the dosing vehicle (commonly PEG), and from the MS/MS transitions used for the analysis. Rapid analysis is essential for drug discovery, and even though the requirements for separation may be minimized for speed, the integrity of the analysis is still dependent on the separation. This paper focuses on the potential for interferences from various endogenous and exogenous matrix components commonly encountered in quantitation of analytes and their metabolites from biological matrices. We demonstrate that neither high organic isocratic nor ballistic gradient ultra‐fast HPLC show a clearly defined advantage in regards to complex biological matrices. The critical factor in the resolution of matrix interferences still remains in sample preparation. Copyright © 2001 John Wiley & Sons, Ltd.