    The thumb carpometacarpal joint: curvature morphology of the articulating surfaces, mathematical description and mechanical functioning.

    by Henning Dathe, Clemens Dumont, Rainer Perplies, Jochen Fanghänel, Dietmar Kubein-Meesenburg, Hans Nägerl, Martin M Wachowski

    The purpose is to present a mathematical model of the function of the thumb carpometacarpal joint (TCMCJ) based on measurements of human joints. In the TCMCJ both articulating surfaces are saddle-shaped. The aim was to geometrically survey the shapes of the articulating surfaces using precise replicas of 28 TCMCJs. None of these 56 articulating surfaces did mathematically extend the differential geometrical neighbourhood around the main saddle point so that each surface could be characterised by three main parameters: the two extreme radii of curvature in the main saddle point and the angle between the saddles' asymptotics (straight lines). The articulating surfaces, when contacting at the respective main saddle points, are incongruent. Hence, the TCMCJ has functionally five kinematical degrees of freedom (DOF); two DOF belong to flexion/extension, two to ab-/adduction. These four DOF are controlled by the muscular apparatus. The fifth DOF, axial rotation, cannot be adjusted but stabilized by the muscular apparatus so that physiologically under compressive load axial rotation does not exceed an angle of approximately ±3°. The TCMCJ can be stimulated by the muscular apparatus to circumduct. The mechanisms are traced back to the curvature incongruity of the saddle surfaces. Hence we mathematically proved that none of the individual saddle surfaces can be described by a quadratic saddle surface as is often assumed in literature. We derived an algebraic formula with which the articulating surfaces in the TCMCJ can be quantitatively described. This formula can be used to shape the articulating surfaces in physiologically equivalent TCMCJ-prostheses.

    • 1 January 2015
      • Vol. 17  (1) , 75-86

    Characteristic points and cycles in planar kinematics with application to the human gait.

    by Henning Dathe, Riccardo Gezzi, Dietmar Kubein-Meesenburg, Hans Nägerl

    We present a novel method to process kinematical data typically coming from measurements of joints. This method will be illustrated through two examples. We adopt theoretical kinematics together with the principle of least action. We use motion and inverse motion for describing the whole experimental situation theoretically. By using the principle of least action, the data contain information about inherent reference points, which we call characteristic points. These points are unique for direct and inverse motion. They may be viewed as centers of the fixed and moving reference systems. The respective actions of these characteristic points are analytically calculated. The sum of these actions defines the kinematical action. This sum is by design independent of the choice of reference system. The minimality of the kinematical action can be used again to select numerically one representative cycle in empirically given, approximately periodic motions. Finally, we illustrate the theoretical approach making use of two examples worked out, hinge movement and the sagittal component of the movement of a human leg during gait. This approach enables automatic cycle choices for evaluating large databases in order to compare and to distinguish empirically given movements. The procedure can be extended to three dimensional movements.


    • 1 January 2015
      • Vol. 17  (2) , 45-53

    The morphology of the articular surfaces of biological knee joints provides essential guidance for the construction of functional knee endoprostheses.

    by Hans Nägerl, Henning Dathe, Christoph Fiedler, Luiko Gowers, Stephanie Kirsch, Dietmar Kubein-Meesenburg, Clemens Dumont, Martin M Wachowski

    In comparative examinations of kinematics of the knees of humans and pigs in flexional/extensional motion under compressive loads, the significant differential geometric essentials of articular guidance are elaborated to criticise the shaping of the articular surfaces of conventional knee-endoprostheses and to suggest constructional outlines that allow the endoprosthesis to adopt natural knee kinematics. Implantation is discussed with regard to the remaining ligamentous apparatus. Twelve fresh pig knee joints and 19 preserved human knee joints were moved into several flexional/extensional positions. In each joint, the tibia and femur were repeatably caught by metal plates. After removing all ligaments, the tibia and femur were again caught in these positions, and their points of contact were marked on both articular surfaces. Along the marker points, a thin lead wire was glued onto each surface. The positions and shapes of the four contact lines were mapped by teleradiography. All contact lines were found to be plane curves. The medial and lateral planes were parallel, thus defining the joint's sagittal plane. In the human knee, as compared to the lateral, the medial femoral contact line was always shifted anteriorly by several millimetres. The tibial contact curve was laterally convex and medially concave. In the pig knees, the lateral and medial contact lines were asymmetrically placed. Both tibial curves were convex. Both knees represent cam mechanisms (with one degree of freedom) that produce rolling of the articular surfaces during the stance phase. Implantation requires preservation of the anterior cruciate ligament, and ligamentous balancing is disadvantageous.


  • Functional states of mandibular movements and synovial pumps of the temporomandibular joint. Is it possible to provide a biomechanically correct replacement for the TMJ?

    by D. Kubein-Meesenburg, H. Nägerl, J. Fialka-Fricke, W. Hahn, S. Weber, J. Hönig, C. Hansen, J. Fanghänel, K.M. Thieme, D. Ihlow


  • Biomechanics of the mandible and growth extension

    by D. Ihlow, H. Dathe, J. Fanghänel, P. Proff, H. Nägerl, W. Hahn, D. Kubein-Meesenburg, K.M. Thieme

    • 1 January 2011
      • Vol. 13  (3) , 35-42

    Construction-conditioned rollback in total knee replacement: fluoroscopic results.

    by Martin Michael Wachowski, Christoph Fiedler, Tim Alexander Walde, Peter Balcarek, Jan Philipp Schüttrumpf, Stephan Frosch, Karl-Heinz Frosch, Jochen Fanghänel, Riccardo Gezzi, Dietmar Kubein-Meesenburg, et al.

    Firstly, the way of implementing approximatively the initial rollback of the natural tibiofemoral joint (TFJ) in a total knee replacement (AEQUOS G1 TKR) is discussed. By configuration of the curvatures of the medial and lateral articulating surfaces a cam gear mechanism with positive drive can be installed, which works under force closure of the femoral and tibial surfaces. Briefly the geometric design features in flexion/extension are described and construction-conditioned kinematical and functional properties that arise are discussed. Due to a positive drive of the cam gear under the force closure during the stance phase of gait the articulating surfaces predominantly roll. As a result of rolling, a sliding friction is avoided, thus the resistance to motion is reduced during the stance phase. Secondly, in vivo fluoroscopic measurements of the patella tendon angle during flexion/extension are presented. The patella tendon angle/ knee flexion angle characteristic and the kinematic profile in trend were similar to those observed in the native knee during gait (0°-60°).


    • 1 January 2011
      • Vol. 13  (4) , 38-49

    Mathematical study on the guidance of the tibiofemoral joint as theoretical background for total knee replacements.

    by Christoph Fiedler, Riccardo Gezzi, Karl-Heinz Frosch, Martin Michael Wachowski, Dietmar Kubein-Meesenburg, Jochen Dörner, Jochen Fanghänel, Hans Nägerl

    The mathematical approach presented allows main features of kinematics and force transfer in the loaded natural tibiofemoral joint (TFJ) or in loaded knee endoprostheses with asymmetric condyles to be deduced from the spatial curvature morphology of the articulating surfaces. The mathematical considerations provide the theoretical background for the development of total knee replacements (TKR) which closely reproduce biomechanical features of the natural TFJ. The model demonstrates that in flexion/extension such kinematic features as centrodes or slip ratios can be implemented in distinct curvature designs of the contact trajectories in such a way that they conform to the kinematics of the natural TFJ in close approximation. Especially the natural roll back in the stance phase during gait can be reproduced. Any external compressive force system, applied to the TFJ or the TKR, produces two joint reaction forces which--when applying screw theory--represent a force wrench. It consists of a force featuring a distinct spatial location of its line and a torque parallel to it. The dependence of the geometrical configuration of the force wrench on flexion angle, lateral/medial distribution of the joint forces, and design of the slopes of the tuberculum intercondylare is calculated. The mathematical considerations give strong hints about TKR design and show how main biomechanical features of the natural TFJ can be reproduced.

    • 1 January 2010
      • Vol. 12  (4) , 39-47

    Migration of the instantaneous axis of motion during axial rotation in lumbar segments and role of the zygapophysial joints.

    by Martin Michael Wachowski, Thelonius Hawellek, Jan Hubert, Andrea Lehmann, Michael Mansour, Clemens Dumont, Jochen Dörner, Björn Werner Raab, Dietmar Kubein-Meesenburg, Hans Nägerl

    The biomechanical role of the zygapophysial joints was investigated for axial rotations of lumbar segments by recording the positions of the instantaneous helical axis (IHA) against the axial rotational angle and by relating these IHA-positions to anatomical landmarks. Cyclically varying pure axial moments were applied to 3 L1/L2, 7 L3/L4 and 3 L4/L5 segments. There were 800 segment positions per cycle taken by a custom-made high precision 3D-position measuring system. In intact segments IHA-migration reached from one zygapophysial joint to the other IHA-paths came up to 10-60 mm within small angular intervals (±1 deg). After removing the right joints, IHA-migration remained comparable with that of intact segments only for segment positions rotated to the right. Rotation to the left, however, approximately yielded stationary IHA-positions as found after resection of both joints. Hence, IHA-migration is determined by the joints already for small rotational angles. Each type of segment showed a typical pattern of IHA-migration.


    • 1 January 2009
      • Vol. 11  (4) , 3-8

    Non-linearity of flexion-extension characteristics in spinal segments.

    by Hans Nägerl, Thelonius Hawellek, Andrea Lehmann, Jan Hubert, Julia Saptschak, Jochen Dörner, Björn Werner Raab, Jochen Fanghänel, Dietmar Kubein-Meesenburg, Martin Michael Wachowski

    Spinal biomechanics is still known just fragmentary since the only description by angle-torque characteristics without simultaneous recording of migration of the instantaneous helical axis (IHA) is not sufficient. Time-dependent flexion/extension following a cyclic laterally directed torque was measured at all six degrees of freedom by a highly precise custom-made 6D apparatus. In order to enhance the localizing resolution of IHA migration as the function of the flexional/extensional angle, small ranges of motion (ROM) were used at several degrees of pre-extension. 4 L3/L4, 3 L4/L5 and 2 T2/T3 human segments were investigated. In extensional motion, wide dorsal IHA-migrations were measured in lumbar segments and correlated with the distinct asymmetric shapes of the characteristics in extensional motion. The respective increase of differential stiffness could mainly be traced back to the enlarging geometrical moment of inertia of the segments by the dorsally migrating IHA. Both thoracic segments showed a predominant IHA-migration in cranial/caudal direction. A simple model makes it evident that the opposite curvature morphology of lumbar and thoracic joint facets conditions the different directions of IHA migration.


    • 1 November 2008
      • p. 75-80

    Mandible, maxilla and cervical spine--a functional unit?

    by D Kubein-Meesenburg, K M Thieme, S Weber, J Fanghanel, C Dumont, A Spassov, W Hahn, D Ihlow, H Nagerl

    The motion patterns of mandibular points were recorded in vivo in closed, free movements of the mandible parallel to the sagittal-vertical plane. The points ran along loops which were valued by their area and length. All points whose loops included the same area under regarding the sense of circulation formed a straight line. Lines belonging to different areas were parallel. When the absolute areas of the oops were plotted for particular points a hollow depression with two minima resulted. The point that showed the lowest minimum in the depression corresponded to the position of the neuromuscular mandibular axis of rotation. The points running along equal loop lengths formed elliptical lines with a minimum below the condyle. The lines of constant loop area and loop length were overlaid with lateral radiographs, to match the patterns of motion with anatomical structures. The mandibular axis of rotation lay mostly cranial anterior of the condyle whereas the point with the shortest path lay mainly below this axis point, inside the bony structures. The row of teeth in the maxilla was found to be located below the line of minimal loop lengths. The cervical spine was arranged along the depression of the minimal absolute areas.