Ratna Tantra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ratna Tantra has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Dipak Gohil
Advanced Engineered Materials Group, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK
3 shared publicationsMartin J. T. Milton
National Physical Laboratory, Analytical Sciences, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
2 shared publications- Richard James Christopher Brown
National Physical Laboratory
2 shared publications A. D. Jones
Institute of Occupational Medicine
1 shared publicationAlex Cackett
Nanoanalysis Group, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK
1 shared publication- Alex E. Knight
Analytical Science Division, National Physical Laboratory, Teddington, Middlesex, TW11 0LW, UK
1 shared publication
Latest Publications
- 4 September 2014
- Published by Taylor & Francis in Nanotoxicology
- Vol. 9 (5) , 636-642
Nano(Q)SAR: Challenges, pitfalls and perspectives
Regulation for nanomaterials is urgently needed, and the drive to adopt an intelligent testing strategy is evident. Such a strategy will not only provide economic benefits but will also reduce moral and ethical concerns arising from animal testing. For regulatory purposes, such an approach is promoted by REACH, particularly the use of quantitative structure–activity relationships [(Q)SAR] as a tool for the categorisation of compounds according to their physicochemical and toxicological properties. In addition to compounds, (Q)SAR has also been applied to nanomaterials in the form of nano(Q)SAR. Although (Q)SAR in chemicals is well established, nano(Q)SAR is still in early stages of development and its successful uptake is far from reality. This article aims to identify some of the pitfalls and challenges associated with nano-(Q)SARs in relation to the categorisation of nanomaterials. Our findings show clear gaps in the research framework that must be addressed if we are to have reliable predictions from such models. Three major barriers were identified: the need to improve quality of experimental data in which the models are developed from, the need to have practical guidelines for the development of the nano(Q)SAR models and the need to standardise and harmonise activities for the purpose of regulation. Of these three, the first, i.e. the need to improve data quality requires immediate attention, as it underpins activities associated with the latter two. It should be noted that the usefulness of data in the context of nano-(Q)SAR modelling is not only about the quantity of data but also about the quality, consistency and accessibility of those data.
- 4 September 2014
- Published by Taylor & Francis in Nanotoxicology
- Vol. 9 (5) , 636-642
Nano(Q)SAR: Challenges, pitfalls and perspectives
Regulation for nanomaterials is urgently needed, and the drive to adopt an intelligent testing strategy is evident. Such a strategy will not only provide economic benefits but will also reduce moral and ethical concerns arising from animal testing. For regulatory purposes, such an approach is promoted by REACH, particularly the use of quantitative structure–activity relationships [(Q)SAR] as a tool for the categorisation of compounds according to their physicochemical and toxicological properties. In addition to compounds, (Q)SAR has also been applied to nanomaterials in the form of nano(Q)SAR. Although (Q)SAR in chemicals is well established, nano(Q)SAR is still in early stages of development and its successful uptake is far from reality. This article aims to identify some of the pitfalls and challenges associated with nano-(Q)SARs in relation to the categorisation of nanomaterials. Our findings show clear gaps in the research framework that must be addressed if we are to have reliable predictions from such models. Three major barriers were identified: the need to improve quality of experimental data in which the models are developed from, the need to have practical guidelines for the development of the nano(Q)SAR models and the need to standardise and harmonise activities for the purpose of regulation. Of these three, the first, i.e. the need to improve data quality requires immediate attention, as it underpins activities associated with the latter two. It should be noted that the usefulness of data in the context of nano-(Q)SAR modelling is not only about the quantity of data but also about the quality, consistency and accessibility of those data.
- 15 July 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (2-3) , 263-270
Variability of microchip capillary electrophoresis with conductivity detection
- 15 July 2013
- Published by Wiley in Electrophoresis
- Vol. 35 (2-3) , 263-270
Variability of microchip capillary electrophoresis with conductivity detection
- 9 April 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 13 (12) , 2199-2201
Product qualification: a barrier to point-of-care microfluidic-based diagnostics?
One of the most exciting applications of microfluidics-based diagnostics is its potential use in next generation point-of-care (POC) devices. Many prototypes are already in existence, but, as of yet, few have achieved commercialisation. In this article, we consider the issue surrounding product qualification as a potential barrier to market success. The study discusses, in the context of POC microfluidics-based diagnostics, what the generic issues are and potential solutions. Our findings underline the need for a community-based effort that is necessary to speed up the product qualification process.
- 9 April 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 13 (12) , 2199-2201
Product qualification: a barrier to point-of-care microfluidic-based diagnostics?
One of the most exciting applications of microfluidics-based diagnostics is its potential use in next generation point-of-care (POC) devices. Many prototypes are already in existence, but, as of yet, few have achieved commercialisation. In this article, we consider the issue surrounding product qualification as a potential barrier to market success. The study discusses, in the context of POC microfluidics-based diagnostics, what the generic issues are and potential solutions. Our findings underline the need for a community-based effort that is necessary to speed up the product qualification process.
- Open Access
- 31 October 2011
- Published by Hindawi Limited in Journal of Toxicology
- Vol. 2012, 1-7
Measurement of Redox Potential in Nanoecotoxicological Investigations
Redox potential has been identified by the Organisation for Economic Co-operation and Development (OECD) as one of the parameters that should be investigated for the testing of manufactured nanomaterials. There is still some ambiguity concerning this parameter, i.e., as to what and how to measure, particularly when in a nanoecotoxicological context. In this study the redox potentials of six nanomaterials (either zinc oxide (ZnO) or cerium oxide (CeO2)) dispersions were measured using an oxidation-reduction potential (ORP) electrode probe. The particles under testing differed in terms of their particle size and dispersion stability in deionised water and in various ecotox media. The ORP values of the various dispersions and how they fluctuate relative to each other are discussed. Results show that the ORP values are mainly governed by the type of liquid media employed, with little contributions from the nanoparticles. Seawater was shown to have reduced the ORP value, which was attributed to an increase in the concentration of reducing agents such as sulphites or the reduction of dissolved oxygen concentration. The lack of redox potential value contribution from the particles themselves is thought to be due to insufficient interaction of the particles at the Pt electrode of the ORP probe.
- 31 October 2011
- Published by Hindawi Limited in Journal of Toxicology
- Vol. 2012, 1-7
Open AccessMeasurement of Redox Potential in Nanoecotoxicological Investigations
Redox potential has been identified by the Organisation for Economic Co-operation and Development (OECD) as one of the parameters that should be investigated for the testing of manufactured nanomaterials. There is still some ambiguity concerning this parameter, i.e., as to what and how to measure, particularly when in a nanoecotoxicological context. In this study the redox potentials of six nanomaterials (either zinc oxide (ZnO) or cerium oxide (CeO2)) dispersions were measured using an oxidation-reduction potential (ORP) electrode probe. The particles under testing differed in terms of their particle size and dispersion stability in deionised water and in various ecotox media. The ORP values of the various dispersions and how they fluctuate relative to each other are discussed. Results show that the ORP values are mainly governed by the type of liquid media employed, with little contributions from the nanoparticles. Seawater was shown to have reduced the ORP value, which was attributed to an increase in the concentration of reducing agents such as sulphites or the reduction of dissolved oxygen concentration. The lack of redox potential value contribution from the particles themselves is thought to be due to insufficient interaction of the particles at the Pt electrode of the ORP probe.
- 27 September 2011
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 13 (12) , 6683-6698
A hypothetical model for predicting the toxicity of high aspect ratio nanoparticles (HARN)
- 27 September 2011
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 13 (12) , 6683-6698
A hypothetical model for predicting the toxicity of high aspect ratio nanoparticles (HARN)
- 26 February 2011
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 13 (9) , 3765-3780
Dispersion stability of nanoparticles in ecotoxicological investigations: the need for adequate measurement tools
- 26 February 2011
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 13 (9) , 3765-3780
Dispersion stability of nanoparticles in ecotoxicological investigations: the need for adequate measurement tools
- 16 September 2010
- Published by Taylor & Francis in Nanotoxicology
- Vol. 5 (3) , 381-392
Cellular uptake and intracellular fate of engineered nanoparticles: A review on the application of imaging techniques
The use of imaging tools to probe nanoparticle-cell interactions will be crucial to elucidating the mechanisms of nanoparticle-induced toxicity. Of particular interest are mechanisms associated with cell penetration, translocation and subsequent accumulation inside the cell, or in cellular compartments. The objective of the present paper is to review imaging techniques that have been previously used in order to assess such interactions, and new techniques with the potential to be useful in this area. In order to identify the most suitable techniques, they were evaluated and matched against a list of evaluation criteria. We conclude that limitations exist with all of the techniques and the ultimate choice will thus depend on the needs of end users, and their particular application. The state-of-the-art techniques appear to have the least limitations, despite the fact that they are not so well established and still far from being routine. For example, super-resolution microscopy techniques appear to have many advantages for understanding the details of the interactions between nanoparticles and cells. Future research should concentrate on further developing or improving such novel techniques, to include the development of standardized methods and appropriate reference materials.
- 16 September 2010
- Published by Taylor & Francis in Nanotoxicology
- Vol. 5 (3) , 381-392
Cellular uptake and intracellular fate of engineered nanoparticles: A review on the application of imaging techniques
The use of imaging tools to probe nanoparticle-cell interactions will be crucial to elucidating the mechanisms of nanoparticle-induced toxicity. Of particular interest are mechanisms associated with cell penetration, translocation and subsequent accumulation inside the cell, or in cellular compartments. The objective of the present paper is to review imaging techniques that have been previously used in order to assess such interactions, and new techniques with the potential to be useful in this area. In order to identify the most suitable techniques, they were evaluated and matched against a list of evaluation criteria. We conclude that limitations exist with all of the techniques and the ultimate choice will thus depend on the needs of end users, and their particular application. The state-of-the-art techniques appear to have the least limitations, despite the fact that they are not so well established and still far from being routine. For example, super-resolution microscopy techniques appear to have many advantages for understanding the details of the interactions between nanoparticles and cells. Future research should concentrate on further developing or improving such novel techniques, to include the development of standardized methods and appropriate reference materials.
- 1 January 2010
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 75 (1) , 275-281
Characterisation of the de-agglomeration effects of bovine serum albumin on nanoparticles in aqueous suspension
- 1 January 2010
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 75 (1) , 275-281
Characterisation of the de-agglomeration effects of bovine serum albumin on nanoparticles in aqueous suspension
- 14 October 2009
- Published by Elsevier in Particuology
- Vol. 7 (6) , 471-476
Effective platform for the generation of aerosol droplets and application in evaluating the effectiveness of a MEMS-based nanoparticle trapping device
- 14 October 2009
- Published by Elsevier in Particuology
- Vol. 7 (6) , 471-476
Effective platform for the generation of aerosol droplets and application in evaluating the effectiveness of a MEMS-based nanoparticle trapping device
- 1 September 2008
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 62 (9) , 992-1000
A Practical Method to Fabricate Gold Substrates for Surface-Enhanced Raman Spectroscopy
We describe a practical method of fabricating surface-enhanced Raman spectroscopy (SERS) substrates based on dip-coating poly-l-lysine derivatized microscope slides in a gold colloidal suspension. The use of only commercially available starting materials in this preparation is particularly advantageous, aimed at both reducing time and the inconsistency associated with surface modification of substrates. The success of colloid deposition has been demonstrated by scanning electron microscopy (SEM) and the corresponding SERS response (giving performance comparable to the corresponding traditional colloidal SERS substrates). Reproducibility was evaluated by conducting replicate measurements across six different locations on the substrate and assessing the extent of the variability (standard deviation values of spectral parameters: peak width and height), in response to either Rhodamine 6G or Isoniazid. Of particular interest is the observation of how some peaks in a given spectrum are more susceptible to data variability than others. For example, in a Rhodamine 6G SERS spectrum, spectral parameters of the peak at 775 cm−1 were shown to have a relative standard deviation (RSD) % of −1 has a RSD of ≥10%. This observation is best explained by taking into account spectral variations that arise from the effect of a chemisorption process and the local nature of chemical enhancement mechanisms, which affects the enhancement of some spectral peaks but not others (analogous to resonant Raman phenomenon).
- 1 September 2008
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 62 (9) , 992-1000
A Practical Method to Fabricate Gold Substrates for Surface-Enhanced Raman Spectroscopy
We describe a practical method of fabricating surface-enhanced Raman spectroscopy (SERS) substrates based on dip-coating poly-l-lysine derivatized microscope slides in a gold colloidal suspension. The use of only commercially available starting materials in this preparation is particularly advantageous, aimed at both reducing time and the inconsistency associated with surface modification of substrates. The success of colloid deposition has been demonstrated by scanning electron microscopy (SEM) and the corresponding SERS response (giving performance comparable to the corresponding traditional colloidal SERS substrates). Reproducibility was evaluated by conducting replicate measurements across six different locations on the substrate and assessing the extent of the variability (standard deviation values of spectral parameters: peak width and height), in response to either Rhodamine 6G or Isoniazid. Of particular interest is the observation of how some peaks in a given spectrum are more susceptible to data variability than others. For example, in a Rhodamine 6G SERS spectrum, spectral parameters of the peak at 775 cm−1 were shown to have a relative standard deviation (RSD) % of −1 has a RSD of ≥10%. This observation is best explained by taking into account spectral variations that arise from the effect of a chemisorption process and the local nature of chemical enhancement mechanisms, which affects the enhancement of some spectral peaks but not others (analogous to resonant Raman phenomenon).