Fabrice Sergent
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fabrice Sergent has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
L. Marpeau
Clinique gynécologique et obstétricale, CHU de Rouen et université de Rouen, 1, rue de Germont, 76031 Rouen, France
13 shared publications- L. Marpeau
Service de gynécologie-obstétrique, CHU Charles-Nicolle, 1, rue de Germont, 76000 Rouen, France
9 shared publications Loïc Marpeau
Department of Obstetrics and Gynecology, Rouen University Hospital, 1, rue de Germont-76031 Rouen Cedex, France
8 shared publications- Eric Verspyck
Professeur des universités- Praticien hospitalier: Service de Gynécologie- Obstétrique, CHU Hôpital Charles Nicolle, 1 rue Germont, 76000 Rouen, France
7 shared publications E. Verspyck
6 shared publicationsBenoît Resch
Department of Obstetrics and Gynecology, Rouen University Hospital, 1, rue de Germont-76031 Rouen Cedex, France
4 shared publications
Latest Publications
- 1 March 2014
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 42 (3) , 182-184
Décidualisation ectopique géante du péritoine et de l’épiploon mimant une carcinose péritonéale
- 1 March 2014
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 42 (3) , 182-184
Décidualisation ectopique géante du péritoine et de l’épiploon mimant une carcinose péritonéale
- 30 September 2010
- Published by Elsevier in The American Journal of Surgery
- Vol. 200 (3) , 406-412
Biomechanical analysis of polypropylene prosthetic implants for hernia repair: an experimental study
- 30 September 2010
- Published by Elsevier in The American Journal of Surgery
- Vol. 200 (3) , 406-412
Biomechanical analysis of polypropylene prosthetic implants for hernia repair: an experimental study
- Open Access
- 1 February 2010
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 89 (2) , 223-229
Treatment of concomitant prolapse and stress urinary incontinence via a transobturator subvesical mesh without independent suburethral tape
Objective. Evaluate the efficacy of a transobturator subvesical mesh for cystocele in concomitant stress urinary incontinence (SUI). Design. Longitudinal observational study. Setting. Tertiary referral urogynecology center. Population. One hundred and five women with at least an anterior vaginal wall prolapse and concomitant SUI who underwent surgery. Methods. After reduction of prolapse elements, the intervention consisted of a non-absorbable monoprosthesis placement with two transobturator expansions and, if necessary, associated hysterectomy or infraccocygeal sacropexy. No specific procedure was performed for SUI. Main outcome measures. All patients had a physical examination and a subjective symptoms assessment via questionnaire in the preoperative period and at one-year or more after surgery. The pelvic organ prolapse quantification system was used for anatomical results. For SUI, Ingelman-Sundberg classification and cough test were used. Loss of urine was measured by a one-hour pad test. Functional results were evaluated by visual analog scale, quality-of-life questionnaires, including the pelvic floor distress inventory and the pelvic floor impact questionnaire. Results. Median follow-up was 45 months (range: 12–72). A total of 102 women (97%) were cured of their prolapse, of whom 72 (69%) were cured of their SUI and 13 (12%) showed improvement. Pad test, visual analogic scale and quality-of-life questionnaires were all improved (p < 0.05). Complications consisted of one rectal injury, one transitory urinary retention, and two hematomas. Of the erosions 6% was observed for monofilament polypropylene prostheses. Conclusion. Transvaginal monoprosthesis for the simultaneous correction of prolapse and SUI represents an effective treatment for bulky or recurrent prolapse as well as posthysterectomy vaginal vault prolapse.
- 1 February 2010
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 89 (2) , 223-229
Open AccessTreatment of concomitant prolapse and stress urinary incontinence via a transobturator subvesical mesh without independent suburethral tape
Objective. Evaluate the efficacy of a transobturator subvesical mesh for cystocele in concomitant stress urinary incontinence (SUI). Design. Longitudinal observational study. Setting. Tertiary referral urogynecology center. Population. One hundred and five women with at least an anterior vaginal wall prolapse and concomitant SUI who underwent surgery. Methods. After reduction of prolapse elements, the intervention consisted of a non-absorbable monoprosthesis placement with two transobturator expansions and, if necessary, associated hysterectomy or infraccocygeal sacropexy. No specific procedure was performed for SUI. Main outcome measures. All patients had a physical examination and a subjective symptoms assessment via questionnaire in the preoperative period and at one-year or more after surgery. The pelvic organ prolapse quantification system was used for anatomical results. For SUI, Ingelman-Sundberg classification and cough test were used. Loss of urine was measured by a one-hour pad test. Functional results were evaluated by visual analog scale, quality-of-life questionnaires, including the pelvic floor distress inventory and the pelvic floor impact questionnaire. Results. Median follow-up was 45 months (range: 12–72). A total of 102 women (97%) were cured of their prolapse, of whom 72 (69%) were cured of their SUI and 13 (12%) showed improvement. Pad test, visual analogic scale and quality-of-life questionnaires were all improved (p < 0.05). Complications consisted of one rectal injury, one transitory urinary retention, and two hematomas. Of the erosions 6% was observed for monofilament polypropylene prostheses. Conclusion. Transvaginal monoprosthesis for the simultaneous correction of prolapse and SUI represents an effective treatment for bulky or recurrent prolapse as well as posthysterectomy vaginal vault prolapse.
- 22 January 2010
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 109 (2) , 131-135
Perioperative course and medium‐term outcome of the transobturator and infracoccygeal hammock for posthysterectomy vaginal vault prolapse
Objective: To describe the perioperative course and medium‐term anatomic and functional outcomes of the transobturator–infracoccygeal hammock for posthysterectomy vaginal vault prolapse repair.Methods: A prospective consecutive series of 52 women with a stage 2 vaginal vault prolapse or higher that occurred after total hysterectomy who underwent surgery between 2003 and 2007. Principal outcome measures were anatomic cure (stage 1 or lower) and impact on quality of life measured using the pelvic floor distress inventory (PFDI) and pelvic floor impact self‐reported questionnaire (PFIQ). Anatomical results were analyzed using χ2 and Fisher exact tests, and PFDI and PFIQ scores were analyzed using the Wilcoxon test.Results: With a median follow‐up of 36 months, the anatomic cure rate was 96%. Significant improvements were noted in POPQ‐S scores after surgery (P < 0.05). Stress urinary incontinence was cured in 73% of patients and improved in 15% of patients. The PFDI and PFIQ scores were improved (P < 0.05). One mesh extrusion was observed. The rates of mesh contraction and new cases of dyspareunia were 31% and 13%, respectively.Conclusion: The transvaginal mesh hammock represents a useful treatment for recurrent and major vaginal vault prolapse, and has few complications.
- 22 January 2010
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 109 (2) , 131-135
Perioperative course and medium‐term outcome of the transobturator and infracoccygeal hammock for posthysterectomy vaginal vault prolapse
Objective: To describe the perioperative course and medium‐term anatomic and functional outcomes of the transobturator–infracoccygeal hammock for posthysterectomy vaginal vault prolapse repair.Methods: A prospective consecutive series of 52 women with a stage 2 vaginal vault prolapse or higher that occurred after total hysterectomy who underwent surgery between 2003 and 2007. Principal outcome measures were anatomic cure (stage 1 or lower) and impact on quality of life measured using the pelvic floor distress inventory (PFDI) and pelvic floor impact self‐reported questionnaire (PFIQ). Anatomical results were analyzed using χ2 and Fisher exact tests, and PFDI and PFIQ scores were analyzed using the Wilcoxon test.Results: With a median follow‐up of 36 months, the anatomic cure rate was 96%. Significant improvements were noted in POPQ‐S scores after surgery (P < 0.05). Stress urinary incontinence was cured in 73% of patients and improved in 15% of patients. The PFDI and PFIQ scores were improved (P < 0.05). One mesh extrusion was observed. The rates of mesh contraction and new cases of dyspareunia were 31% and 13%, respectively.Conclusion: The transvaginal mesh hammock represents a useful treatment for recurrent and major vaginal vault prolapse, and has few complications.
- 1 November 2009
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 147 (1) , 106-110
Mechanical evaluation of synthetic biomaterials used in the correction of pelvic floor disorders—Experimental study in rabbits
- 1 November 2009
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 147 (1) , 106-110
Mechanical evaluation of synthetic biomaterials used in the correction of pelvic floor disorders—Experimental study in rabbits
- 1 April 2009
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 37 (4) , 353-357
Bandelettes sous-urétrales et incontinence urinaire d’effort
- 1 April 2009
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 37 (4) , 353-357
Bandelettes sous-urétrales et incontinence urinaire d’effort
- 17 February 2009
- Published by Springer Nature in International Urogynecology Journal
- Vol. 20 (5) , 597-604
Experimental biomechanical evaluation of polypropylene prostheses used in pelvic organ prolapse surgery
Introduction and hypothesis Although polypropylene (PP) is the most common biomaterial used to repair genital prolapse via vaginal route, its mechanical properties however remain obscure. Methods An abdominal hernia rabbit model was used to evaluate retraction, solidity, and elasticity of the principal types of PP prostheses currently available, i.e., three large pore size monofilament prostheses, one heavy weight (HWPP), a second low weight (LWPP), and a third coated with atelocollagen (CPP). A small pore size multifilament PP (MPP) implant was also tested. Results In comparison with HWPP (12%), LWPP (15%), and MPP (30%), CPP had less retraction (8% of the original size). Unlike pore size, weight prosthesis is not an influencing factor for retraction. Atelocollagen coating reduced retraction. HWPP and MPP were the most solid prostheses. MPP supported the greatest elastic force. Conclusions When the biomechanical parameters were comparatively assessed, HWPP was considered to have the most advantageous properties for prolapse surgery.
- 17 February 2009
- Published by Springer Nature in International Urogynecology Journal
- Vol. 20 (5) , 597-604
Experimental biomechanical evaluation of polypropylene prostheses used in pelvic organ prolapse surgery
Introduction and hypothesis Although polypropylene (PP) is the most common biomaterial used to repair genital prolapse via vaginal route, its mechanical properties however remain obscure. Methods An abdominal hernia rabbit model was used to evaluate retraction, solidity, and elasticity of the principal types of PP prostheses currently available, i.e., three large pore size monofilament prostheses, one heavy weight (HWPP), a second low weight (LWPP), and a third coated with atelocollagen (CPP). A small pore size multifilament PP (MPP) implant was also tested. Results In comparison with HWPP (12%), LWPP (15%), and MPP (30%), CPP had less retraction (8% of the original size). Unlike pore size, weight prosthesis is not an influencing factor for retraction. Atelocollagen coating reduced retraction. HWPP and MPP were the most solid prostheses. MPP supported the greatest elastic force. Conclusions When the biomechanical parameters were comparatively assessed, HWPP was considered to have the most advantageous properties for prolapse surgery.
- 1 December 2007
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 35 (12) , 1239-1241
Récidive d’incontinence urinaire d’effort après bandelette sous-urétrale et accouchement
- 1 December 2007
- Published by Elsevier in Gynécologie Obstétrique & Fertilité
- Vol. 35 (12) , 1239-1241
Récidive d’incontinence urinaire d’effort après bandelette sous-urétrale et accouchement
- 1 September 2007
- Published by Elsevier in Journal de Gynécologie Obstétrique et Biologie de la Reproduction
- Vol. 36 (5) , 459-467
Correction prothétique des prolapsus génito-urinaires selon la technique du hamac transobturateur infracoccygien: résultats à moyen terme
- 1 September 2007
- Published by Elsevier in Journal de Gynécologie Obstétrique et Biologie de la Reproduction
- Vol. 36 (5) , 459-467
Correction prothétique des prolapsus génito-urinaires selon la technique du hamac transobturateur infracoccygien: résultats à moyen terme