GPG. Piskoty

G. Piskoty

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


G. Piskoty has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • B. Weisse

    Swiss Federal Laboratories for Materials Testing and Research (EMPA), Dübendorf, Switzerland

    2 shared publications
  • Giovanni Pietro Terrasi

    Empa, Swiss Federal Laboratories for Materials Science and Technology

    2 shared publications
  • M. Zgraggen

    Empa, Swiss Federal Laboratories for Materials Testing and Research, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland

    2 shared publications
  • Silvain Michel

    Mechanical Systems Engineering Laboratory, Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf, Switzerland

    2 shared publications
  • A. Fürst

    Vetsuisse Faculty of the University of Zurich, Zürich, Switzerland

    1 shared publication
  • Ch. Affolter

    Empa, Swiss Federal Laboratories for Materials Testing and Research, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland

    1 shared publication

Latest Publications

  • Scheme of the Failure Analysis Taking the Example of Profile Wire Breaks in the Support Cable of a Cable Car System

    by R. E. Koller, G. Piskoty, M. Zgraggen

    Cable car systems are predominantly used in the Alpine Region for the transportation of passengers and goods. During operation, their components are subjected to environmental influences as well as to static and dynamic loads. Even if standards, measurements, experimental tests, periodic inspections, and maintenance are considered, a component failure can not be entirely excluded. It is for that reason that cases of damage in the cable car industry are clarified based on systematic analyses aiming at prevention and an increase in security. The approach for the identification of the underlying causes of a case of failure is presented using the example of a spectacular incident in 2004 where all external profile wires of a support cable of a 100 passenger aerial tramway broke during operation. A precautionary and thorough preservation of evidence, detailed examinations of the subject components, clarifications of the operating history of the system, as well as an eventual identification of a probable damage process supported by examination findings are essential steps of this approach. The findings of such evaluations are the basis for recommendations regarding testing and construction of further systems, their operation, maintenance, and inspections with a focus on damage prevention.


  • Resistance of equine tibiae and radii to side impact loads

    by G. Piskoty, S. Jäggin, S. A. Michel, B. Weisse, G. P. Terrasi, A. Fürst

    Summary: Reasons for performing study: There are no detailed studies describing the resistance of equine tibiae and radii to side impact loads, such as a horse kick and a better understanding of the general long bone impact behavioural model is required. Objectives: To quantify the typical impact energy required to fracture or fissure an equine long bone, as well as to determine the range and time course of the impact force under conditions similar to that of a horse kick. Methods: Seventy‐two equine tibiae and radii were investigated using a drop impact tester. The prepared bones were preloaded with an axial force of 2.5 kN and were then hit in the middle of the medial side. The impact velocity of the metal impactor, weighting 2 kg, was varied within the range of 6–11 m/s. The impact process was captured with a high‐speed camera from the craniomedial side of the bone. The videos were used both for slow‐motion observation of the process and for quantifying physical parameters, such as peak force via offline video tracking and subsequent numerical derivation of the ‘position vs. time’ function for the impactor. Results: The macroscopic appearance of the resultant bone injuries was found to be similar to those produced by authentic horse kicks, indicating a successful simulation of the real load case. The impact behaviours of tibiae and radii do not differ considerably in terms of the investigated general characteristics. Peak force occurred between 0.15–0.30 ms after the start of the impact. The maximum contact force correlated with the 1.45‐power of the impact velocity if no fracture occurred ( F max ≅ 0.926 ·v i 1.45 ). Peak force scatter was considerably larger within the fractured sub‐group compared with fissured bones. The peak force for fracture tended to lie below the aforementioned function, within the range of F max = 11–23 kN (‘fracture load’). The impact energy required to fracture a bone varied from 40–90 J. Conclusions: The video‐based measuring method allowed quantifying of the most relevant physical parameters, such as contact force and energy balance. Potential relevance: The results obtained should help with the development of bone implants and guards, supporting theoretical studies, and in the evaluation of bone injuries.


  • Structural failures of rope-based systems

    by G. Piskoty, M. Zgraggen, B. Weisse, Ch. Affolter, G. Terrasi