Ernest Beinrohr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ernest Beinrohr has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Frantisek Cacho
Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37, Bratislava, Slovakia
5 shared publications Alena Manova
Institute of Analytical Chemistry, Slovak University of Technology, Radlinského 9, 812 37 Bratislava, Slovakia
3 shared publicationsLukas Lauko
Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinskeho 9, 812 37 Bratislava, Slovakia
3 shared publicationsKatarina Lenghartova
Department of Chemistry, Faculty of Natural Sciences, University of SS. Cyril and Methodius in Trnava, J. Herdu 2, 917 01 Trnava, Slovakia
2 shared publicationsA. Manova
Slovak University of Technology, Institute of Analytical Chemistry, Radlinskeho 9, 812 37 Bratislava, Slovakia
1 shared publicationA. Manová
Slovak Technical University
1 shared publication
Latest Publications
- Open Access
- 15 March 2015
- Published by Slovenian Chemical Society in Acta Chimica Slovenica
- Vol. 62 (1) , 152-158-8
Determination of Nitrites in Water by In-electrode Coulometric Titration in Reticulated Vitreous Carbon Electrode
Determination of Nitrites in Water by In-electrode Coulometric Titration in Reticulated Vitreous Carbon Electrode
- 15 March 2015
- Published by Slovenian Chemical Society in Acta Chimica Slovenica
- Vol. 62 (1) , 152-158-8
Open AccessDetermination of Nitrites in Water by In-electrode Coulometric Titration in Reticulated Vitreous Carbon Electrode
Determination of Nitrites in Water by In-electrode Coulometric Titration in Reticulated Vitreous Carbon Electrode
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1473-1478
Determination of Nitrates in Water Samples by In-Electrode Coulometric Titration in Copper Coated Porous Vitreous Carbon Electrode
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1473-1478
Determination of Nitrates in Water Samples by In-Electrode Coulometric Titration in Copper Coated Porous Vitreous Carbon Electrode
- Open Access
- 12 January 2012
- Published by Hindawi Limited in Journal of Analytical Methods in Chemistry
- Vol. 2012, 1-6
Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation
Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm-3and 2.7 μg dm-3, respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm-3for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant.
- 12 January 2012
- Published by Hindawi Limited in Journal of Analytical Methods in Chemistry
- Vol. 2012, 1-6
Open AccessSequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation
Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm-3and 2.7 μg dm-3, respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm-3for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant.
- 13 October 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (12) , 1913-1917
Determination of nickel in hair samples by graphite furnace atomic absorption spectrometry and flow-through stripping chronopotentiometry
Nickel in hair samples was determined by GF AAS and stripping chronopotentiometry after a dry ashing mineralisation with a mixture of nitrous oxides, oxygen and ozone. The use of common matrix modifiers brought no significant improvement in the GF AAS measurement. The detection limit, trueness and precision were found to be 0.15 mg kg−1 of the hair sample, 4.3%, and 4.1%, respectively. The linear range was found to be 0.44–3.3 mg kg−1. The stripping chronopotentiometric determination is based on the deposition of nickel ions from an ammonia buffer solution in a porous glassy carbon electrode followed by its stripping into an acidic solution by constant current. Copper interfered and was removed from the acidified sample solution by means of a minicolumn packed with pearl cellulose chemically modified with 8-hydroxychinolinol. Copper was trapped completely whereas nickel passed the column. The detection limit, trueness and precision were found to be 0.032 mg kg−1 in the hair sample, 5.8%, and 6.1%, respectively. The linear range was found to be 0.1–20 mg kg−1. Good agreement between the two methods was found for most hair samples.
- 13 October 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (12) , 1913-1917
Determination of nickel in hair samples by graphite furnace atomic absorption spectrometry and flow-through stripping chronopotentiometry
Nickel in hair samples was determined by GF AAS and stripping chronopotentiometry after a dry ashing mineralisation with a mixture of nitrous oxides, oxygen and ozone. The use of common matrix modifiers brought no significant improvement in the GF AAS measurement. The detection limit, trueness and precision were found to be 0.15 mg kg−1 of the hair sample, 4.3%, and 4.1%, respectively. The linear range was found to be 0.44–3.3 mg kg−1. The stripping chronopotentiometric determination is based on the deposition of nickel ions from an ammonia buffer solution in a porous glassy carbon electrode followed by its stripping into an acidic solution by constant current. Copper interfered and was removed from the acidified sample solution by means of a minicolumn packed with pearl cellulose chemically modified with 8-hydroxychinolinol. Copper was trapped completely whereas nickel passed the column. The detection limit, trueness and precision were found to be 0.032 mg kg−1 in the hair sample, 5.8%, and 6.1%, respectively. The linear range was found to be 0.1–20 mg kg−1. Good agreement between the two methods was found for most hair samples.
- 26 April 2007
- Published by Springer Nature in Microchimica Acta
- Vol. 159 (1-2) , 41-47
Determination of chromium(VI) and total chromium in water by in-electrode coulometric titration in a porous glassy carbon electrode
- 26 April 2007
- Published by Springer Nature in Microchimica Acta
- Vol. 159 (1-2) , 41-47
Determination of chromium(VI) and total chromium in water by in-electrode coulometric titration in a porous glassy carbon electrode
- 1 April 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 588 (1) , 16-19
Determination of dissolved sulphides in waste water samples by flow-through stripping chronopotentiometry with a macroporous mercury-film electrode
- 1 April 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 588 (1) , 16-19
Determination of dissolved sulphides in waste water samples by flow-through stripping chronopotentiometry with a macroporous mercury-film electrode
- 1 January 2007
- Published by Springer Nature in Chemical Papers
- Vol. 61 (6) , 452-456
Determination of As(III) and total as in water by graphite furnace atomic absorption spectrometry after electrochemical preconcentration on a gold-plated porous glassy carbon electrode
Arsenic(III) was preconcentrated in a flow-through electrochemical cell on a gold coated porous carbon electrode. On stripping, arsenic was eluted with diluted nitric acid and determined off-line by GF AAS. The deposition and stripping steps were optimized. The limit of detection and limit of quantification were found to be 1.9 µg L−1 and 6.4 µg L−1, respectively. The repeatability and reproducibility were found to be 5.3 % and 9.3 %, respectively. Total arsenic was determined after a microwave assisted chemical reduction of As(V) to As(III) making the procedure suitable for speciation analysis. The method was applied in analysis of water samples.
- 1 January 2007
- Published by Springer Nature in Chemical Papers
- Vol. 61 (6) , 452-456
Determination of As(III) and total as in water by graphite furnace atomic absorption spectrometry after electrochemical preconcentration on a gold-plated porous glassy carbon electrode
Arsenic(III) was preconcentrated in a flow-through electrochemical cell on a gold coated porous carbon electrode. On stripping, arsenic was eluted with diluted nitric acid and determined off-line by GF AAS. The deposition and stripping steps were optimized. The limit of detection and limit of quantification were found to be 1.9 µg L−1 and 6.4 µg L−1, respectively. The repeatability and reproducibility were found to be 5.3 % and 9.3 %, respectively. Total arsenic was determined after a microwave assisted chemical reduction of As(V) to As(III) making the procedure suitable for speciation analysis. The method was applied in analysis of water samples.