Vasilios D. Polyzois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vasilios D. Polyzois has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Theodoros B. Grivas
Orthopaedic & Spinal Surgeon, Former Head of the Traumatology and Orthopaedic Department, Tzaneio General Hospital of Piraeus, Greece
3 shared publications Thomas Zgonis
Division of Podiatric Medicine and Surgery, Department of Orthopaedic Surgery, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Drive–MSC 7776, San Antonio, TX 78229, USA
3 shared publicationsIoannis Papakostas
General Hospital of Limnos, Limnos 81400, Greece
2 shared publicationsPanayotis Stavlas
2 shared publicationsAlexandros E. Beris
Department of Orthopaedics and Traumatology, University of Ioannina Medical School, PO Box 1186, 451 10 Ioannina, Greece
1 shared publicationAndreas Gkiokas
Department of Orthopaedic Surgery and Traumatology, P and A Kyriakou Children's Hospital, Athens, Greece
1 shared publication
Latest Publications
- 31 July 2010
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 27 (3) , 463-467
Combined Distraction Osteogenesis and Papineau Technique for an Open Fracture Management of the Distal Lower Extremity
- 31 July 2010
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 27 (3) , 463-467
Combined Distraction Osteogenesis and Papineau Technique for an Open Fracture Management of the Distal Lower Extremity
- 1 February 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (2) , E21-E23
Management of Knee Dislocation Because of Posttraumatic Septic Arthritis Neglected for 40 Years
- 1 February 2008
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 64 (2) , E21-E23
Management of Knee Dislocation Because of Posttraumatic Septic Arthritis Neglected for 40 Years
- 1 April 2006
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 23 (2) , 241-255
Pediatric Fractures of the Foot and Ankle
- 1 April 2006
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 23 (2) , 241-255
Pediatric Fractures of the Foot and Ankle
- 1 April 2006
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 23 (2) , 455-465
Current Concepts and Techniques in Posttraumatic Arthritis
- 1 April 2006
- Published by Elsevier in Clinics in Podiatric Medicine and Surgery
- Vol. 23 (2) , 455-465
Current Concepts and Techniques in Posttraumatic Arthritis
- 2 March 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (2) , 122-128
A modified technique for the treatment of intra-articular calcaneal fractures with the use of the Ilizarov apparatus
- 2 March 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (2) , 122-128
A modified technique for the treatment of intra-articular calcaneal fractures with the use of the Ilizarov apparatus
- 30 April 2004
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 14 (3) , 188-191
Bent femoral intramedullary nails: a report of two cases with need for urgent removal
Two cases of bent intramedullary femoral nail removal are presented. Both patients had to be operated, for different reasons, as soon as possible. A metal cutting blade was used as an option for partial or full sectioning of the nails. For both cases, a lateral approach was required. For one case, this approach had to be combined with a small anteromedial incision so that the blade could move across the thigh. One nail was removed in one piece and the other in two pieces separately. Both nails were exchanged with other interlocked nails. Both fractures healed without complications despite the extensive and relatively traumatic approach. Our rationale for nail sectioning depending on angulation elements is presented and proposed. Deux cas d’ablation de clou fémoral plié sont présentés. Les deux patients avaient dû, pour diverses raisons, être opérés aussi vite que possible. Une lame de scie à métal fut utilisée pour couper les clous. Dans les deux cas un abord latéral externe fut nécessaire. Dans l’un des cas, cet abord fut complété par une petite incision antéro-médiale, pour permettre à la lame de scie de travailler par-dessus la cuisse. L’un des clous fut enlevé en une pièce et l’autre en deux pièces. Les deux clous furent remplacés par des clous verrouillés. Les deux fractures guérirent sans complications, malgré cet abord traumatisant.
- 30 April 2004
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 14 (3) , 188-191
Bent femoral intramedullary nails: a report of two cases with need for urgent removal
Two cases of bent intramedullary femoral nail removal are presented. Both patients had to be operated, for different reasons, as soon as possible. A metal cutting blade was used as an option for partial or full sectioning of the nails. For both cases, a lateral approach was required. For one case, this approach had to be combined with a small anteromedial incision so that the blade could move across the thigh. One nail was removed in one piece and the other in two pieces separately. Both nails were exchanged with other interlocked nails. Both fractures healed without complications despite the extensive and relatively traumatic approach. Our rationale for nail sectioning depending on angulation elements is presented and proposed. Deux cas d’ablation de clou fémoral plié sont présentés. Les deux patients avaient dû, pour diverses raisons, être opérés aussi vite que possible. Une lame de scie à métal fut utilisée pour couper les clous. Dans les deux cas un abord latéral externe fut nécessaire. Dans l’un des cas, cet abord fut complété par une petite incision antéro-médiale, pour permettre à la lame de scie de travailler par-dessus la cuisse. L’un des clous fut enlevé en une pièce et l’autre en deux pièces. Les deux clous furent remplacés par des clous verrouillés. Les deux fractures guérirent sans complications, malgré cet abord traumatisant.