MEMark J. Eagle

Mark J. Eagle

*This is an algorithmically generated author record based on publicly available information.

Mark J. Eagle has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of an improved bone washing and demineralisation process to produce large demineralised human cancellous bone sponges

    by Mark J. Eagle, Paul Rooney, John N. Kearney

    Shaped demineralised bone matrices (DBM) made from cancellous bone have important uses in orthopaedic and dental procedures, where the properties of the material allow its insertion into confined defects, therefore acting as a void filler and scaffold onto which new bone can form. The sponges are often small in size, 3. In this study, we report on an improved bone washing and demineralisation process that allows production of larger DBM sponges (3.375 or 8.0 cm3) from deceased donor bone. These sponges were taken through a series of warm water washes, some with sonication, centrifugation, 100 % ethanol and two decontamination chemical washes and optimally demineralised using 0.5 N hydrochloric acid under vacuum. Demineralisation was confirmed by quantitative measurement of calcium and qualitatively by compression. Protein and DNA removal was also determined. The DBM sponges were freeze dried before terminal sterilisation with a target dose of 25 kGy gamma irradiation whilst frozen. Samples of the sponges were examined histologically for calcium, collagen and the presence of cells. The data indicated lack of cells, absence of bone marrow and a maximum of 1.5 % residual calcium.


  • Development of a validation protocol to determine the ability of screw-top containers to be watertight and to withstand impact damage from accidental dropping

    by M. J. Eagle, P. Rooney, J. N. Kearney

    Polypropylene screw-top containers are used to collect, transport and store a variety of tissues within tissue banks. These containers are validated for use by tissue banks but no standard validation protocol is used. We present here a protocol for testing screw-top containers for leakage, evaporation and the ability to withstand accidental impact damage. Three different containers were tested, MedFor S072, MedFor S277 and MacoPharma PROT0483. The validation can detect differences between different manufacturer’s containers and this protocol will be used in future validations of screw-top containers within National Blood Service Tissue Services.

  • Investigating the warming and cooling rates of human cadavers by development of a gel-filled model to validate core temperature

    by M. J. Eagle, P. Rooney, J. N. Kearney

    Tissue Services (within NHS Blood and Transplant) plans to bring deceased donors to its state of the art retrieval suite at its new centre in Speke, Liverpool in air-conditioned transport at circa 20°C but without dedicated active cooling. The aim of this study was to determine how quickly a refrigerated body would warm at different ambient temperatures using a gel-filled model. Two models of a human body were prepared consisting of neoprene wetsuits filled with approximately 7 or 18 l of a viscous solution, which once set has similar properties to ballistics gel. This gel consisted of 47.5% distilled water, 47.5% glycerol and 5% agar. Final “dummy” weights were 7.4 and 18.6 kg respectively, representing “virtual” weights of approximately 40 kg and 70 kg. A K-class thermocouple probe was then inserted into a “rectal” position within each model and the models were cooled to a series of different core temperatures: 5°C, 10°C and 15°C and then were placed in an orbital incubator set at 20°C or 30°C ambient temperature. The rate of temperature increase, in the dummy, was measured, until the model’s core temperature was close to the ambient temperature. This was done in triplicate for each size model and ambient temperature. Data indicate that increase in core temperature depends on the size of the model and the initial core temperature. For an equivalent donor weight of 70 kg and background temperature of 20°C, core temperature rises from 5°C to 9.2°C; 10°C to 13.3°C and 15°C to 15.5°C after 2 h. The final core temperatures after 2 h are likely to retard bacterial growth, movement or contamination during transport. Cooling rate data indicated that a 70 kg donor equivalent cooled from 37°C to 15°C within 6 h in a cold room at 4°C. This work has shown that a body can be transported without refrigeration and not cause further tissue deterioration as a result.


  • Validation of Radiation Dose Received by Frozen Unprocessed and Processed Bone during Terminal Sterilisation

    by M.J. Eagle, P. Rooney, R. Lomas, J.N. Kearney

    Fresh frozen femoral heads (FH) and frozen processed bone (FP) are widely used as a source of allograft bone. The FP bone and some of the FH are terminally sterilised by the National Blood Service Tissue Services (NSBTS), via application of a minimum 25 kGy gamma radiation dose. To comply with the Guidelines for the Blood Transfusion Services in the United Kingdom (2002), frozen musculoskeletal tissue must be maintained below −40 °C during storage and transit. In practice, NBSTS stores bone long-term in −80 °C freezers. During transport for irradiation, a temperature of circa −79 °C is maintained by packing the bone in dry ice. An evaluation of the radiation dose received by bone has previously been made via dosimeters located within the tissue and dry ice, however, some evidence suggests that low temperature can influence the accuracy of the dosimeter readings. The aim of this study was to determine the actual radiation dose received by FH and FP bone during the irradiation process. This was accomplished by comparing radiation dose readings from dosimeters placed in dry ice with dosimeters placed in a dry ice substitute of similar dimensions and density i.e., polytetrafluoroethylene (PTFE) at ambient temperature. New packing formats were developed for both FH and FP bone such that 15 FH or 3 kg of FP bone could be irradiated in one transport box at any given time in a standardised fashion. The data show that low temperature consistently increased dosimeter readings 10–27%, and that radiation dose always fell within the range of 25–40 kGy (FH = 25.1–35.7 kGy; FP bone = 25.2–32.4 kGy).