Norimichi Tsumura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Norimichi Tsumura has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Hideaki Haneishi
Chiba University
3 shared publications- Toshiya Nakaguchi
Center of Frontier Medical Engineering, Chiba University, Chiba 263-8522, Japan
3 shared publications Y. Miyake
3 shared publicationsYoichi Miyake
Chiba University
3 shared publications- T. Koishi
Chiba Univ. (Japan)
2 shared publications A. Kikuchi
1 shared publication
Latest Publications
- 1 May 2011
- Published by Society for Imaging Science & Technology in Journal of Imaging Science and Technology
- Vol. 55 (3) , 30102-1
Erratum: Relationship Between Ambient Illumination and Psychological Effects for Television Viewing
- 1 May 2011
- Published by Society for Imaging Science & Technology in Journal of Imaging Science and Technology
- Vol. 55 (3) , 30102-1
Erratum: Relationship Between Ambient Illumination and Psychological Effects for Television Viewing
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 726127
Deformable hollow organ models with self-collision processing between inner surfaces
This paper presents a deformable hollow organ model considering the self-collision between the inner surfaces of a hollow organ for real-time surgical simulation. The hollow organ was modeled by the finite element method with 10400 tetrahedral elements, 2160 nodes, and 1040 inner meshes. In the model, the continuous collision detection is performed between the inner surfaces to prevent penetrations of them. As a result, it was shown that the model is well-behaved about 40 fps by a standard PC with Pentium4 3GHz and 2GB RAM.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 726127
Deformable hollow organ models with self-collision processing between inner surfaces
This paper presents a deformable hollow organ model considering the self-collision between the inner surfaces of a hollow organ for real-time surgical simulation. The hollow organ was modeled by the finite element method with 10400 tetrahedral elements, 2160 nodes, and 1040 inner meshes. In the model, the continuous collision detection is performed between the inner surfaces to prevent penetrations of them. As a result, it was shown that the model is well-behaved about 40 fps by a standard PC with Pentium4 3GHz and 2GB RAM.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 72610B
Absolute length measurement using manually decided stereo correspondence for endoscopy
In recent years, various kinds of endoscope have been developed and widely used to endoscopic biopsy, endoscopic operation and endoscopy. The size of the inflammatory part is important to determine a method of medical treatment. However, it is not easy to measure absolute size of inflammatory part such as ulcer, cancer and polyp from the endoscopic image. Therefore, it is required measuring the size of those part in endoscopy. In this paper, we propose a new method to measure the absolute length in a straight line between arbitrary two points based on the photogrammetry using endoscope with magnetic tracking sensor which gives camera position and angle. In this method, the stereo-corresponding points between two endoscopic images are determined by the endoscopist without any apparatus of projection and calculation to find the stereo correspondences, then the absolute length can be calculated on the basis of the photogrammetry. The evaluation experiment using a checkerboard showed that the errors of the measurements are less than 2% of the target length when the baseline is sufficiently-long.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261, 72610B
Absolute length measurement using manually decided stereo correspondence for endoscopy
In recent years, various kinds of endoscope have been developed and widely used to endoscopic biopsy, endoscopic operation and endoscopy. The size of the inflammatory part is important to determine a method of medical treatment. However, it is not easy to measure absolute size of inflammatory part such as ulcer, cancer and polyp from the endoscopic image. Therefore, it is required measuring the size of those part in endoscopy. In this paper, we propose a new method to measure the absolute length in a straight line between arbitrary two points based on the photogrammetry using endoscope with magnetic tracking sensor which gives camera position and angle. In this method, the stereo-corresponding points between two endoscopic images are determined by the endoscopist without any apparatus of projection and calculation to find the stereo correspondences, then the absolute length can be calculated on the basis of the photogrammetry. The evaluation experiment using a checkerboard showed that the errors of the measurements are less than 2% of the target length when the baseline is sufficiently-long.
- 1 November 2000
- Published by Springer Nature in Optical Review
- Vol. 7 (6) , 479-482
Independent Component Analysis of Spectral Absorbance Image in Human Skin
- 1 November 2000
- Published by Springer Nature in Optical Review
- Vol. 7 (6) , 479-482
Independent Component Analysis of Spectral Absorbance Image in Human Skin
- 1 September 1999
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 16 (9) , 2169-2176
Independent-component analysis of skin color image
The spatial distributions of melanin and hemoglobin in human skin are separated by independent-component analysis of a skin color image. The analysis is based on the skin color model with three assumptions: (1) Spatial variation of color in the skin is caused by two pigments, melanin and hemoglobin; (2) the quantities of the two pigments are mutually independent spatially; and (3) linearity holds among the quantities and the observed color signals in the optical density domain. The results of the separation agree well with physiological knowledge. The separated components are synthesized to simulate the various facial color images by changing the quantities of the two separated pigments.
- 1 September 1999
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 16 (9) , 2169-2176
Independent-component analysis of skin color image
The spatial distributions of melanin and hemoglobin in human skin are separated by independent-component analysis of a skin color image. The analysis is based on the skin color model with three assumptions: (1) Spatial variation of color in the skin is caused by two pigments, melanin and hemoglobin; (2) the quantities of the two pigments are mutually independent spatially; and (3) linearity holds among the quantities and the observed color signals in the optical density domain. The results of the separation agree well with physiological knowledge. The separated components are synthesized to simulate the various facial color images by changing the quantities of the two separated pigments.
- 1 January 1999
- Published by Springer Nature in Optical Review
- Vol. 6 (1) , 57-61
Limitation of Color Samples for Spectral Estimation from Sensor Responses in Fine Art Painting
- 1 January 1999
- Published by Springer Nature in Optical Review
- Vol. 6 (1) , 57-61
Limitation of Color Samples for Spectral Estimation from Sensor Responses in Fine Art Painting