Freddy C. Adams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Freddy C. Adams has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Heidi Goenaga Infante
Micro and Trace Analysis Centre (MiTAC), Department of Chemistry, University of Antwerp (UIA), Universiteitsplein 1, Antwerp, Belgium
6 shared publicationsKarima Benkhedda
Micro and Trace Analysis Centre (MiTAC), Department of Chemistry, University of Antwerp (UIA), Universiteitsplein 1, Antwerp, Belgium
4 shared publicationsElisaveta Ivanova
Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, Sofia, Bulgaria
3 shared publicationsWilly Van Mol
University of Antwerp (UIA), Micro and Trace Analysis Centre, Universiteitsplein 1, Wilrijk, Belgium
2 shared publicationsA. Adriaens
Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent, Belgium
1 shared publicationAnnemie Adriaens
Micro & Trace Analysis Centre, University of Antwerp (UIA), B-2610 Wilrijk, Belgium
1 shared publication
Latest Publications
- 27 June 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (9) , 1019-1025
Simultaneous on-line preconcentration and determination of Pt, Rh and Pd in urine, serum and road dust by flow injection combined with inductively coupled plasma time-of-flight mass spectrometry
In this work, ICP-time of flight (TOF)-MS with ultrasonic nebulisation (USN) was combined on-line with a flow injection (FI) system for the determination of Pt, Rh and Pd in biological fluids (urine and blood serum) and road dust. Simultaneous and selective preconcentration of the 3 analytes was performed by sorption of their complexes formed on-line with diethylthiourea (DET) on the inner walls of a PTFE knotted reactor (KR), in a wide range of sample acidity (0.1–0.5 M HNO3 for Pd and Rh and 0.05–0.2 M HNO3 for Pt). A quantitative elution was achieved using 500 µl methanol acidified with 1% HNO3 . The detection limits obtained were 0.54, 2.12 and 0.36 ng l−1 for Pt, Rh and Pd, respectively, and the relative standard deviation RSD (for 50 ng l−1 of Pt, Rh and 25 ng l−1 of Pd, n = 6) was ≤ 3%. Using a preconcentration time of 120 s and a sample flow rate of 5 ml min−1, enrichment factors of 55, 5 and 2 for Pd, Pt and Rh, respectively, were obtained in comparison with direct determination by ICP-MS without preconcentration. Special attention was paid to the study of the adverse effects of potentially interfering species present in the matrix (Cd, Cu, Pb, Sr, Fe, Y, Zn, Ni, Rb, Mn and Mo) on the preconcentration and the mass-spectrometric determination of the analytes. The accuracy of the method was demonstrated by the analysis of urine, blood serum and road dust certified reference materials. The method was applied to urine and serum samples of healthy subjects. The concentrations of Pt, Rh and Pd determined in these samples were comparable to reported values.
- 27 June 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (9) , 1019-1025
Simultaneous on-line preconcentration and determination of Pt, Rh and Pd in urine, serum and road dust by flow injection combined with inductively coupled plasma time-of-flight mass spectrometry
In this work, ICP-time of flight (TOF)-MS with ultrasonic nebulisation (USN) was combined on-line with a flow injection (FI) system for the determination of Pt, Rh and Pd in biological fluids (urine and blood serum) and road dust. Simultaneous and selective preconcentration of the 3 analytes was performed by sorption of their complexes formed on-line with diethylthiourea (DET) on the inner walls of a PTFE knotted reactor (KR), in a wide range of sample acidity (0.1–0.5 M HNO3 for Pd and Rh and 0.05–0.2 M HNO3 for Pt). A quantitative elution was achieved using 500 µl methanol acidified with 1% HNO3 . The detection limits obtained were 0.54, 2.12 and 0.36 ng l−1 for Pt, Rh and Pd, respectively, and the relative standard deviation RSD (for 50 ng l−1 of Pt, Rh and 25 ng l−1 of Pd, n = 6) was ≤ 3%. Using a preconcentration time of 120 s and a sample flow rate of 5 ml min−1, enrichment factors of 55, 5 and 2 for Pd, Pt and Rh, respectively, were obtained in comparison with direct determination by ICP-MS without preconcentration. Special attention was paid to the study of the adverse effects of potentially interfering species present in the matrix (Cd, Cu, Pb, Sr, Fe, Y, Zn, Ni, Rb, Mn and Mo) on the preconcentration and the mass-spectrometric determination of the analytes. The accuracy of the method was demonstrated by the analysis of urine, blood serum and road dust certified reference materials. The method was applied to urine and serum samples of healthy subjects. The concentrations of Pt, Rh and Pd determined in these samples were comparable to reported values.
- 24 June 2003
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 128 (8) , 1104-1109
A comparison of microbeam techniques for the analysis of corroded ancient bronze objects
This paper describes the use of several microbeam analysis techniques for the chemical characterization of corrosion compounds on ancient bronze objects. They include optical microscopy, SEM-EDX, TOF-SIMS, SR-FTIR, SR-XRD, and XANES. The objective is to investigate which combination of analysis methods is most suitable for this type of application, taking into account aspects such as limited sampling and the ability of obtaining spatial information. Results show that SR-XRD in combination with optical microscopy and SEM-EDX is able to provide a complete description of the layered structure both on elemental and molecular level.
- 24 June 2003
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 128 (8) , 1104-1109
A comparison of microbeam techniques for the analysis of corroded ancient bronze objects
This paper describes the use of several microbeam analysis techniques for the chemical characterization of corrosion compounds on ancient bronze objects. They include optical microscopy, SEM-EDX, TOF-SIMS, SR-FTIR, SR-XRD, and XANES. The objective is to investigate which combination of analysis methods is most suitable for this type of application, taking into account aspects such as limited sampling and the ability of obtaining spatial information. Results show that SR-XRD in combination with optical microscopy and SEM-EDX is able to provide a complete description of the layered structure both on elemental and molecular level.
- 1 May 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 107, 683-686
Present century record of mercury species pollution in high altitude alpine snow and ice
- 1 May 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 107, 683-686
Present century record of mercury species pollution in high altitude alpine snow and ice
- 1 November 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (9-10) , 553-557
Capabilities of surfactant-modified high performance liquid chromatography for fractionation of mammalian metallothioneins
- 1 November 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (9-10) , 553-557
Capabilities of surfactant-modified high performance liquid chromatography for fractionation of mammalian metallothioneins
- 4 October 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (11) , 1492-1497
Gas chromatography-inductively coupled plasma-time-of-flight mass spectrometry as a tool for speciation analysis of organomercury compounds in environmental and biological samples
An inductively coupled plasma-time-of-flight mass spectrometer has been combined with a capillary gas chromatograph for the speciation analysis of inorganic and methylmercury. The derivatisation and volatilisation of the ionic mercury species from the sample was achieved by in-situ ethylation with sodium tetraethyl borate (NaBEt4) in a purge-and-trap injection (PTI) system. The potential of the ICP-TOFMS for detection of fast transient signals with peak widths significantly shorter than 1 s with high temporal fidelity and ultra-trace sensitivity was demonstrated. A thorough optimisation of the instrumental parameters led to absolute detection limits of 20 fg and 1.5 pg and relative detection limits of 2 and 150 pg l−1for methylmercury and inorganic mercury, respectively. The accuracy of the method was demonstrated by the analysis of two certified reference materials, a freeze dried tuna fish (CRM 464) and a dogfish muscle (DORM-2), and by recovery measurements on spiked samples. Application to ultra-trace speciation analysis of organomercury compounds in ice from the French Alps has been addressed.
- 4 October 2002
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (11) , 1492-1497
Gas chromatography-inductively coupled plasma-time-of-flight mass spectrometry as a tool for speciation analysis of organomercury compounds in environmental and biological samples
An inductively coupled plasma-time-of-flight mass spectrometer has been combined with a capillary gas chromatograph for the speciation analysis of inorganic and methylmercury. The derivatisation and volatilisation of the ionic mercury species from the sample was achieved by in-situ ethylation with sodium tetraethyl borate (NaBEt4) in a purge-and-trap injection (PTI) system. The potential of the ICP-TOFMS for detection of fast transient signals with peak widths significantly shorter than 1 s with high temporal fidelity and ultra-trace sensitivity was demonstrated. A thorough optimisation of the instrumental parameters led to absolute detection limits of 20 fg and 1.5 pg and relative detection limits of 2 and 150 pg l−1for methylmercury and inorganic mercury, respectively. The accuracy of the method was demonstrated by the analysis of two certified reference materials, a freeze dried tuna fish (CRM 464) and a dogfish muscle (DORM-2), and by recovery measurements on spiked samples. Application to ultra-trace speciation analysis of organomercury compounds in ice from the French Alps has been addressed.
- 31 May 2002
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 21 (5) , 332-342
Inductively coupled plasma mass spectrometry for trace analysis using flow injection on-line preconcentration and time-of-flight mass analyser
- 31 May 2002
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 21 (5) , 332-342
Inductively coupled plasma mass spectrometry for trace analysis using flow injection on-line preconcentration and time-of-flight mass analyser
- 1 April 2002
- Published by Elsevier in Analytica Chimica Acta
- Vol. 456 (1) , 63-75
Can plasma spectrochemistry assist in improving the accuracy of chemical analysis?
- 1 April 2002
- Published by Elsevier in Analytica Chimica Acta
- Vol. 456 (1) , 63-75
Can plasma spectrochemistry assist in improving the accuracy of chemical analysis?
- 19 December 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (2) , 79-87
Inductively coupled plasma time-of-flight mass spectrometry coupled to high-performance liquid chromatography for multi-elemental speciation analysis of metalloproteins in carp cytosols
Size-exclusion high-performance liquid chromatography (SE-HPLC) was coupled on-line with axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS). This hybrid approach was assessed for characterization of metallothioneins (MT) as well as for speciation of ultra-trace metals associated to the MT fraction in cytosol samples of the common carp. The separation of commercial gel-filtration standards with molecular weights that ranged from 1 355 to 540 000 Da was performed in a SUPELCO TSK gel G 3000 PWxL gel-filtration column using 30 mmol l−1 Tris-HCl (pH 7.4, flow 0.8 ml min−1) as a mobile phase. The proteins were first detected on-line spectrophotometrically at 254 and 280 nm, then specific detection of metals was performed using ICP-TOFMS. The potential of the ICP-TOFMS instrument as a fast transient detector for the quasi-simultaneous multi-elemental speciation of 16 isotopes bound to biomolecules of different size, after separation, was assessed using minute volumes of sample. The detection limits (3σ) for Cd, Zn and Cu bound to rabbit liver MT varied from 19.9 ± 0.5 pg (for 114Cd) to 158 ± 7 pg (for 66Zn). Application of this hyphenated method to investigate the distribution of ultra-trace heavy metals among different size fractions of liver and kidney cytosols of carp and their relation with the induction of MT after exposure to Cd in water was addressed. The induction of Cd–MT in kidney was found to be a “biomarker” for exposure to ppb levels of Cd in water. Complementary anion-exchange chromatography was used in combination with ICP-TOFMS detection for multi-elemental speciation of MT fractions, previously isolated by SE-HPLC, in kidney and liver of stressed carp. Metal speciation of MT in vertebrate fish seemed to be similar to that observed for mammalian MT. A clear difference in terms of metal–protein associations was found between the MT fractions in carp kidney and liver tissues.
- 19 December 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (2) , 79-87
Inductively coupled plasma time-of-flight mass spectrometry coupled to high-performance liquid chromatography for multi-elemental speciation analysis of metalloproteins in carp cytosols
Size-exclusion high-performance liquid chromatography (SE-HPLC) was coupled on-line with axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS). This hybrid approach was assessed for characterization of metallothioneins (MT) as well as for speciation of ultra-trace metals associated to the MT fraction in cytosol samples of the common carp. The separation of commercial gel-filtration standards with molecular weights that ranged from 1 355 to 540 000 Da was performed in a SUPELCO TSK gel G 3000 PWxL gel-filtration column using 30 mmol l−1 Tris-HCl (pH 7.4, flow 0.8 ml min−1) as a mobile phase. The proteins were first detected on-line spectrophotometrically at 254 and 280 nm, then specific detection of metals was performed using ICP-TOFMS. The potential of the ICP-TOFMS instrument as a fast transient detector for the quasi-simultaneous multi-elemental speciation of 16 isotopes bound to biomolecules of different size, after separation, was assessed using minute volumes of sample. The detection limits (3σ) for Cd, Zn and Cu bound to rabbit liver MT varied from 19.9 ± 0.5 pg (for 114Cd) to 158 ± 7 pg (for 66Zn). Application of this hyphenated method to investigate the distribution of ultra-trace heavy metals among different size fractions of liver and kidney cytosols of carp and their relation with the induction of MT after exposure to Cd in water was addressed. The induction of Cd–MT in kidney was found to be a “biomarker” for exposure to ppb levels of Cd in water. Complementary anion-exchange chromatography was used in combination with ICP-TOFMS detection for multi-elemental speciation of MT fractions, previously isolated by SE-HPLC, in kidney and liver of stressed carp. Metal speciation of MT in vertebrate fish seemed to be similar to that observed for mammalian MT. A clear difference in terms of metal–protein associations was found between the MT fractions in carp kidney and liver tissues.
- 4 May 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (9) , 995-1001
Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor
A flow injection (FI) on-line sorption system, for the preconcentration and separation in a knotted reactor (KR), is coupled with inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) for the fast, selective and sensitive determination of ultra-trace concentrations of rare earth elements (REEs) in environmental waters. The on-line preconcentration and separation of the REEs is achieved by sorption of the REE complexes formed in the pH range 3.7–4.6 on the inner walls of a (300 cm × 0.5 mm) PTFE KR pre-coated with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP) at a pH of 9.6. The analytes are eluted and transported to the ICP-TOFMS system with 2% (v/v) HNO3 containing 0.5 µg l−1 of Rh and In as internal standards, using ultrasonic nebulisation. The REEs are effectively preconcentrated and separated from the major matrix constituents—alkali and alkaline earth elements. Of particular significance is their separation from barium, which produces considerable isobaric interferences on some of the analytes. Using a preconcentration time of 30 s and a sample flow rate of 4.4 ml min−1, enhancement factors of 15 to 22 for the different REES are achieved. The detection limits (3σ) range from 3 to 40 pg l−1. The precision for 9 replicate determinations of 0.1 µg l−1 of each analyte is better than 5% (RSD). The accuracy of the method is demonstrated by the analysis of environmental waters and by recovery measurements on spiked samples.
- 4 May 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (9) , 995-1001
Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor
A flow injection (FI) on-line sorption system, for the preconcentration and separation in a knotted reactor (KR), is coupled with inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) for the fast, selective and sensitive determination of ultra-trace concentrations of rare earth elements (REEs) in environmental waters. The on-line preconcentration and separation of the REEs is achieved by sorption of the REE complexes formed in the pH range 3.7–4.6 on the inner walls of a (300 cm × 0.5 mm) PTFE KR pre-coated with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP) at a pH of 9.6. The analytes are eluted and transported to the ICP-TOFMS system with 2% (v/v) HNO3 containing 0.5 µg l−1 of Rh and In as internal standards, using ultrasonic nebulisation. The REEs are effectively preconcentrated and separated from the major matrix constituents—alkali and alkaline earth elements. Of particular significance is their separation from barium, which produces considerable isobaric interferences on some of the analytes. Using a preconcentration time of 30 s and a sample flow rate of 4.4 ml min−1, enhancement factors of 15 to 22 for the different REES are achieved. The detection limits (3σ) range from 3 to 40 pg l−1. The precision for 9 replicate determinations of 0.1 µg l−1 of each analyte is better than 5% (RSD). The accuracy of the method is demonstrated by the analysis of environmental waters and by recovery measurements on spiked samples.
- 11 September 2000
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 368 (2) , 288-292
Electrothermal atomic absorption spectrometric determination of cobalt in biological samples and natural waters using a flow injection system with on-line preconcentration by ion-pair adsorption in a knotted reactor.
- 11 September 2000
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 368 (2) , 288-292
Electrothermal atomic absorption spectrometric determination of cobalt in biological samples and natural waters using a flow injection system with on-line preconcentration by ion-pair adsorption in a knotted reactor.