MPMirko Prosek

Mirko Prosek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mirko Prosek has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 June 2011
      • Vol. 58  (2) , 203-11

    Overview of the development and application of the hyphenated techniques in nutritional analysis.

    by Darja Kotnik, Andrej Smidovnik, Petra Jazbec-Križman, Mitja Križman, Mirko Prošek

    The development of some sensitive assays for quantitative nutritional analysis with an emphasis on selected hyphenated analytical techniques is reviewed in the present paper. The majority of work is dedicated to reviewing the development of analytical tools for routine analysis of carbohydrates and lipids in biological samples, many of them introduced in our laboratory. Handling biological matrices, where endogenous compounds can mask the analyte of interest or where the occurrence of the coelution effect of several compounds present in different amounts hinders the analyte's peak integration, is a major challenge. To overcome this challenge, hyphenated techniques have become widespread in laboratory practice. Some of these techniques are reviewed, with special attention given to an effective on-line interface for thin-layer chromatography-mass spectrometry and on-line coupling thin-layer chromatography-gas chromatography. Recently introduced an on-line coupling of ion chromatograph and hybrid RF/DC quadrupole-linear ion trap mass spectrometer represent an analytical tool for the solution of bioanalytical problems. Developed methods using ion chromatography-pulsed amperometric detection and ion chromatography-mass spectrometry techniques for the quantitative evaluation of sugars are presented. This paper represents basic contributions of our research work connected with some of modern hyphenated techniques. However, this review is restricted to the published papers to be significant developments or improvements during the last three decades.


  • Open Access

    Quantitative Determination of Coenyzme Q10 by Liquid Chromatography and Liquid Chromatography/Mass Spectrometry in Dairy Products

    by Monika Strazisar, Maja Fir, Alenka Golc-Wondra, Luka Milivojevic, Mirko Prosek, Veronika Abram

    The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25°C on a Hyperclone ODS 5 μm 150 × 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 ± 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3.0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 μm, 150 × 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 ± 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+m/z 863.4 ± 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75–90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.


  • Open Access

    Determination of Phenylalanine and Tyrosine by Liquid Chromatography/Mass Spectrometry

    by Samo Andrensek, Alenka Golc-Wondra, Mirko Prosek

    Phenylketonuria is a common metabolic disorder disease. Those affected appear normal at birth, but without treatment they develop severe psychomotor retardation. Throughout life, they must control their blood levels of phenylalanine (Phe) and consume a diet containing adequate amounts of Phe and tyrosine (Tyr). We have developed a liquid chromatographic/mass spectrometric (LC/MS) method for the quantitative evaluation of Phe and Tyr in food samples. This method takes advantage of the good separation of LC and the selective and reliable quantification provided by MS in the electrospray ionization mode. The LC/MS method is very suitable for the determination of selected amino acids in various matrixes. It is sensitive to levels as low as about 0.30 ppm for Tyr and 0.70 ppm for Phe and robust. Nearly 100 nondietary food samples were analyzed by the developed method.


  • Open Access

    Uncertainty in quantitative thin-layer chromatography.

    by Mirko Prosek, Alenka Golc-Wondra, Irena Vovk

    Globalization forces analysts to demand extended control of variability in analytical measurements. A calculation procedure named the "error budget model" following recommendations proposed more than 20 years ago by the Bureau International des Poids et Mesures is established as a rule for evaluating and expressing the measurement uncertainty across a broad spectrum of measurements. This metrological approach common in physical measurement is not applicable in separation techniques and cannot quantitate measurement uncertainty. Our experiments show that it can be used as a planning tool in the validation of thin-layer chromatographic (TLC) methods. A computer program that quantitates uncertainty components associated with potential sources of uncertainty in quantitative TLC is prepared and tested with experimental data. TLC plates with different qualities of stationary phases (TLC and high-performance TLC) spotted with different types of samples are measured. Application is performed manually and automatically. Plates are scanned with UV-vis scanners and a video documentation system in remission and transmission mode and fluorescence. Although the calculated values are close to the values obtained with validation procedures, the error budget approach cannot substitute validation. Calculated results can predict critical points in real quantitative TLC, but they cannot confirm the validity of a selected chromatographic procedure.