Khageshwar Singh Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Khageshwar Singh Patel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Peter Hoffmann
Technische Universität Darmstadt , Chemische Analytik, Material und Geowissenschaften , Darmstadt, Germany
4 shared publicationsK. Shrivas
Pt. Ravishankar Shukla University
3 shared publicationsP. Hoffmann
Darmstadt Technical University
3 shared publications- Norbert Jakubowski
Spetec GmbH, 85435 Erding, Germany
2 shared publications Paresh Chandra Sharma
Department of Chemistry , Government Science College , Raipur, CG, India
2 shared publicationsAditya Shukla
School of Studies in Chemistry , Pt. Ravishankar Shukla University , Raipur, 492010, Chattisgarh, India
1 shared publication
Latest Publications
- 10 March 2006
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 28 (1-2) , 11-17
A survey of lead pollution in Chhattisgarh State, central India
Lead (Pb) is of major environmental concern due to its toxicological importance. The anthropogenic emission of Pb is at least 100 times higher than natural emissions. Soil and dust are significant sources of Pb exposure. Lead is generally immobile in soil and accumulates in the upper layers. Lead particles may enter homes via shoes, clothes, pets, and windows. Central India is rich in deposits of natural resource materials such as coal, pyrite, dolomite, and alumina that contain Pb and other heavy metals at the trace levels, and the substantial exploitation of these materials has tended to increased contamination of water and geological formations. Here we present data on Pb concentrations in the water, soil and sediment samples (n=158) collected from 70 locations in Chhattisgarh state, Raipur region. Lead concentrations in the surface water (n=44), groundwater (n=44), soils (n=60) and sediments (n=10) ranged from 6 to 1410, 3 to 52, 12.8 to 545, and 31 to 423 μg g−1, with mean values of 305, 16, 102 and 190 μg g−1, respectively. Most of the Pb fractions of >80% can be leached out with the chemical extractants EDTA, acetic acid, and hydroxylamine hydrochloride. Lead has accumulated in the soil clay fraction due to its relatively large surface area and decreases with increasing depth in the soil profile.
- 10 March 2006
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 28 (1-2) , 11-17
A survey of lead pollution in Chhattisgarh State, central India
Lead (Pb) is of major environmental concern due to its toxicological importance. The anthropogenic emission of Pb is at least 100 times higher than natural emissions. Soil and dust are significant sources of Pb exposure. Lead is generally immobile in soil and accumulates in the upper layers. Lead particles may enter homes via shoes, clothes, pets, and windows. Central India is rich in deposits of natural resource materials such as coal, pyrite, dolomite, and alumina that contain Pb and other heavy metals at the trace levels, and the substantial exploitation of these materials has tended to increased contamination of water and geological formations. Here we present data on Pb concentrations in the water, soil and sediment samples (n=158) collected from 70 locations in Chhattisgarh state, Raipur region. Lead concentrations in the surface water (n=44), groundwater (n=44), soils (n=60) and sediments (n=10) ranged from 6 to 1410, 3 to 52, 12.8 to 545, and 31 to 423 μg g−1, with mean values of 305, 16, 102 and 190 μg g−1, respectively. Most of the Pb fractions of >80% can be leached out with the chemical extractants EDTA, acetic acid, and hydroxylamine hydrochloride. Lead has accumulated in the soil clay fraction due to its relatively large surface area and decreases with increasing depth in the soil profile.
- 1 January 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (1) , 197-205
Flow Injection Analysis Spectrophotometric Determination of Platinum
A new, simple, rapid, and selective procedure for the flow injection analysis (FIA) spectrophotometric determination of platement (Pt) is described. The method is based on the color reaction of Pt(IV) with SnCl2 in the HCl medium. The mixed surfactants, i.e., cetylpyridinium chloride (CPC)+triton X‐100 (TX‐100) are used to enhance sensitivity of the method. The value of apparent molar absorptivity in the term of Pt is (3.00)×103 L mol−1 cm−1 at absorption maximum, 405 nm. The detection limit (causing absorbance greater than 3×std. dev.) of the method is 150 ng/mL−1. The optimum concentration range for the determination of Pt is 0.5–18 µg/mL−1 with slope, intercept and correlation coefficient 0.0086, −0.001, and +0.99, respectively. The sample throughput of the method is 120 samples/h−1 at the flow rate of 3.7 mL/min−1. The composition of the complex, and the reaction mechanism involved are discussed. The effect of FIA and analytical variables on the determination of the metal is optimized. The method has been tested for the analysis of Pt to the catalytic materials.
- 1 January 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (1) , 197-205
Flow Injection Analysis Spectrophotometric Determination of Platinum
A new, simple, rapid, and selective procedure for the flow injection analysis (FIA) spectrophotometric determination of platement (Pt) is described. The method is based on the color reaction of Pt(IV) with SnCl2 in the HCl medium. The mixed surfactants, i.e., cetylpyridinium chloride (CPC)+triton X‐100 (TX‐100) are used to enhance sensitivity of the method. The value of apparent molar absorptivity in the term of Pt is (3.00)×103 L mol−1 cm−1 at absorption maximum, 405 nm. The detection limit (causing absorbance greater than 3×std. dev.) of the method is 150 ng/mL−1. The optimum concentration range for the determination of Pt is 0.5–18 µg/mL−1 with slope, intercept and correlation coefficient 0.0086, −0.001, and +0.99, respectively. The sample throughput of the method is 120 samples/h−1 at the flow rate of 3.7 mL/min−1. The composition of the complex, and the reaction mechanism involved are discussed. The effect of FIA and analytical variables on the determination of the metal is optimized. The method has been tested for the analysis of Pt to the catalytic materials.
- 1 August 2005
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 27 (2) , 131-145
Arsenic contamination in water, soil, sediment and rice of central India
Arsenic contamination in the environment (i.e. surface, well and tube-well water, soil, sediment and rice samples) of central India (i.e. Ambagarh Chauki, Chhattisgarh) is reported. The concentration of the total arsenic in the samples i.e. water (n=64), soil (n=30), sediment (n=27) and rice grain (n=10) were ranged from 15 to 825 μg L−1, 9 to 390 mg kg−1, 19 to 489 mg kg−1 and 0.018 to 0.446 mg kg−1, respectively. In all type of waters, the arsenic levels exceeded the permissible limit, 10 μg L−1. The most toxic and mobile inorganic species i.e. As(III) and As(V) are predominantly present in water of this region. The soils have relatively higher contents of arsenic and other elements i.e. Mg, Al, Si, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Ga, Zr, Sn, Sb, Pb and U. The mean arsenic contents in soil of this region are much higher than in arsenic soil of West Bengal and Bangladesh. The lowest level of arsenic in the soil of this region is 3.7 mg kg−1 with median value of 9.5 mg kg−1. The arsenic contents in the sediments are at least 2-folds higher than in the soil. The sources of arsenic contamination in the soil of this region are expected from the rock weathering as well as the atmospheric deposition. The environmental samples i.e. water, soil dust, food, etc. are expected the major exposure for the arsenic contamination. The most of people living in this region are suffering with arsenic borne diseases (i.e. melanosis, keratosis, skin cancer, etc.).
- 1 August 2005
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 27 (2) , 131-145
Arsenic contamination in water, soil, sediment and rice of central India
Arsenic contamination in the environment (i.e. surface, well and tube-well water, soil, sediment and rice samples) of central India (i.e. Ambagarh Chauki, Chhattisgarh) is reported. The concentration of the total arsenic in the samples i.e. water (n=64), soil (n=30), sediment (n=27) and rice grain (n=10) were ranged from 15 to 825 μg L−1, 9 to 390 mg kg−1, 19 to 489 mg kg−1 and 0.018 to 0.446 mg kg−1, respectively. In all type of waters, the arsenic levels exceeded the permissible limit, 10 μg L−1. The most toxic and mobile inorganic species i.e. As(III) and As(V) are predominantly present in water of this region. The soils have relatively higher contents of arsenic and other elements i.e. Mg, Al, Si, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Ga, Zr, Sn, Sb, Pb and U. The mean arsenic contents in soil of this region are much higher than in arsenic soil of West Bengal and Bangladesh. The lowest level of arsenic in the soil of this region is 3.7 mg kg−1 with median value of 9.5 mg kg−1. The arsenic contents in the sediments are at least 2-folds higher than in the soil. The sources of arsenic contamination in the soil of this region are expected from the rock weathering as well as the atmospheric deposition. The environmental samples i.e. water, soil dust, food, etc. are expected the major exposure for the arsenic contamination. The most of people living in this region are suffering with arsenic borne diseases (i.e. melanosis, keratosis, skin cancer, etc.).
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1991-2001
Determination of Thiocyanate in Waste Water
The present work proposes a new, simple, selective, and sensitive method for the on‐site spectrophotometric determination of SCN− ions in the industrial and municipal waste water. The method is based on color reaction of SCN− ions with V(V) and chelating agent: N‐hydroxy‐N,N′‐diphenylbenzamidine (HODPBA), and subsequent extraction of the deep green colored complex into chloroform. The value of apparent molar absorptivity (at enrichment factor of 5) is 7.00 × 103 L mol−1 cm−1 at λmax = 610 nm. The calibration curve is linear up to 5.0 µg mL−1 SCN− with slope, intercept, and correlation coefficient of 0.120, 0, and +0.99, respectively. The detection limit (an absorbance identical to blank absorbance +thrice of std. dev.) of the method is 66 ng mL−1 SCN− of the aqueous solution. Most of the ions associated did not interfere in the determination of SCN−. Only phenol interfered in the determination of SCN−, and could be removed by the prior extraction with chloroform solution. The method has been used...
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1991-2001
Determination of Thiocyanate in Waste Water
The present work proposes a new, simple, selective, and sensitive method for the on‐site spectrophotometric determination of SCN− ions in the industrial and municipal waste water. The method is based on color reaction of SCN− ions with V(V) and chelating agent: N‐hydroxy‐N,N′‐diphenylbenzamidine (HODPBA), and subsequent extraction of the deep green colored complex into chloroform. The value of apparent molar absorptivity (at enrichment factor of 5) is 7.00 × 103 L mol−1 cm−1 at λmax = 610 nm. The calibration curve is linear up to 5.0 µg mL−1 SCN− with slope, intercept, and correlation coefficient of 0.120, 0, and +0.99, respectively. The detection limit (an absorbance identical to blank absorbance +thrice of std. dev.) of the method is 66 ng mL−1 SCN− of the aqueous solution. Most of the ions associated did not interfere in the determination of SCN−. Only phenol interfered in the determination of SCN−, and could be removed by the prior extraction with chloroform solution. The method has been used...
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1953-1963
Simple and Selective Method for Determination of Platinum with Tin(II) Chloride and Amides
A new, simple, and selective method for rapid spectrophotometric determination of Pt is described. It is based on extraction of Pt(II)–SnCl3 − complex with chloroform (CF) solution of amide, i.e., N‐alkylacetamide (alkyl = butyl to octyl). The value of apparent molar absorptivity of the complex (with four N‐alkylacetamides) lie in the range of (3.40–3.50) × 104 L mol−1 cm−1 at λmax 400–405 nm. The most sensitive compound, i.e., N‐butylacetamide (BAA) has been selected for the detailed studies. The detection limit (absorbance 0.007 more than thrice of standard deviation of the method) of the method is 40 ppb Pt. The types of the halide and amide in the extraction as well as spectral characteristics of the complex are discussed. The reaction mechanism involved in the extraction of the metal is described. The optimization of analytical variables for the determination of Pt is carried out. The method has been applied for the determination of Pt in the catalytic materials.
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1953-1963
Simple and Selective Method for Determination of Platinum with Tin(II) Chloride and Amides
A new, simple, and selective method for rapid spectrophotometric determination of Pt is described. It is based on extraction of Pt(II)–SnCl3 − complex with chloroform (CF) solution of amide, i.e., N‐alkylacetamide (alkyl = butyl to octyl). The value of apparent molar absorptivity of the complex (with four N‐alkylacetamides) lie in the range of (3.40–3.50) × 104 L mol−1 cm−1 at λmax 400–405 nm. The most sensitive compound, i.e., N‐butylacetamide (BAA) has been selected for the detailed studies. The detection limit (absorbance 0.007 more than thrice of standard deviation of the method) of the method is 40 ppb Pt. The types of the halide and amide in the extraction as well as spectral characteristics of the complex are discussed. The reaction mechanism involved in the extraction of the metal is described. The optimization of analytical variables for the determination of Pt is carried out. The method has been applied for the determination of Pt in the catalytic materials.
- 27 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (10) , 2163-2174
Flow‐Injection Analysis Spectrophotometric Determination of Bismuth in Environmental and Pharmaceutical Samples
A new, simple, rapid, selective, and sensitive flow‐injection analysis (FIA) method for the spectrophotometric determination of Bi is described. It is based on reaction of Bi (III) with I− ions in the presence of cationic surfactants (CS), i.e., cetylpyridinium chloride, cetyltrimethylammonium bromide, tetradecyltrimethylammonium bromide, dodecyltrimethylammonium bromide in sulfuric media to give a violet‐colored complex. The apparent value of molar absorpitivity of the complex in the terms of Bi with four CSs lie in the range of (1.00–1.20) × 104 L mol−1 cm−1 at λmax 490 nm. Among them, the most sensitive CSs, i.e., cetylpyridinium chloride (CPC) has been selected for the detailed studies. The detection limit (causing absorbance >3 sec) of the method is 65 µg L−1 Bi. The sample throughput of the method is >120 samples hr−1. The effect of diverse ions and surfactants in the FIA determination of Bi is examined. The composition of the complex is discussed. The analytical and FIA variables in the determination of Bi are optimized. The method has been applied for analysis of Bi in the environmental and pharmaceutical materials.
- 27 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (10) , 2163-2174
Flow‐Injection Analysis Spectrophotometric Determination of Bismuth in Environmental and Pharmaceutical Samples
A new, simple, rapid, selective, and sensitive flow‐injection analysis (FIA) method for the spectrophotometric determination of Bi is described. It is based on reaction of Bi (III) with I− ions in the presence of cationic surfactants (CS), i.e., cetylpyridinium chloride, cetyltrimethylammonium bromide, tetradecyltrimethylammonium bromide, dodecyltrimethylammonium bromide in sulfuric media to give a violet‐colored complex. The apparent value of molar absorpitivity of the complex in the terms of Bi with four CSs lie in the range of (1.00–1.20) × 104 L mol−1 cm−1 at λmax 490 nm. Among them, the most sensitive CSs, i.e., cetylpyridinium chloride (CPC) has been selected for the detailed studies. The detection limit (causing absorbance >3 sec) of the method is 65 µg L−1 Bi. The sample throughput of the method is >120 samples hr−1. The effect of diverse ions and surfactants in the FIA determination of Bi is examined. The composition of the complex is discussed. The analytical and FIA variables in the determination of Bi are optimized. The method has been applied for analysis of Bi in the environmental and pharmaceutical materials.
- 25 May 2004
- Published by Springer Nature in Microchimica Acta
- Vol. 147 (4) , 273-278
Determination of Cationic Surfactants in Environmental Samples by Flow Injection Analysis
- 25 May 2004
- Published by Springer Nature in Microchimica Acta
- Vol. 147 (4) , 273-278
Determination of Cationic Surfactants in Environmental Samples by Flow Injection Analysis