Robert A. Novelline
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Robert A. Novelline has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Mannudeep K. Kalra
Division of Emergency Radiology, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Founders 215, 55 Fruit Street, Boston, MA 02114, USA
2 shared publications- Stefania Rizzo
Department of Radiology, Institute of Integrated Diagnostic of Southern Switzerland (IDISI), Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland
2 shared publications - Ajay Singh
Department of Chemistry, Faculty of Engineering, Teerthanker Mahaveer University, Moradabad-244001, India
1 shared publication - Benjamin B. Lange
Department of Surgery, Fletcher Allen Health Care, University of Vermont College of Medicine, Burlington, VT 05401, USA
1 shared publication - Laura L. Avery
Massachusetts General Hospital
1 shared publication Mohammad Mansouri
Massachusetts General Hospital
1 shared publication
Latest Publications
- 15 November 2024
- Published by Springer Nature
- p. 353-377
Imaging of Spinal Trauma
- 1 November 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 289 (2) , 384-385
CT in the Patient with Multiple Trauma: Risk Factors for Missed Findings
- 1 November 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 289 (2) , 384-385
CT in the Patient with Multiple Trauma: Risk Factors for Missed Findings
- 27 December 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (2) , 115-132
Looking back, moving forward: 1988–2013. The first 25 years of the American Society of Emergency Radiology
The American Society of Emergency Radiology (ASER) was founded in 1988 and is celebrating its 25th Anniversary. ASER is thriving and emergency radiology has never enjoyed greater popularity than at present. This history describes the genesis of the Society, its growth and current state of affairs. It is based on the recollections and personal files of the authors, one Founder and both former ASER Presidents and Gold Medalists, the ASER archives, and interviews and correspondence with many ASER members. It is hoped that this brief review will be interesting to the reader, provide some insight into ASER evolution over the years, and hold some lessons moving forward.
- 27 December 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (2) , 115-132
Looking back, moving forward: 1988–2013. The first 25 years of the American Society of Emergency Radiology
The American Society of Emergency Radiology (ASER) was founded in 1988 and is celebrating its 25th Anniversary. ASER is thriving and emergency radiology has never enjoyed greater popularity than at present. This history describes the genesis of the Society, its growth and current state of affairs. It is based on the recollections and personal files of the authors, one Founder and both former ASER Presidents and Gold Medalists, the ASER archives, and interviews and correspondence with many ASER members. It is hoped that this brief review will be interesting to the reader, provide some insight into ASER evolution over the years, and hold some lessons moving forward.
- 4 September 2009
- Published by Springer Nature in Emergency Radiology
- Vol. 17 (3) , 191-193
Are cervical spine radiograph examinations useful in patients with low clinical suspicion of cervical spine fracture? An experience with 254 cases
Trauma patients with low clinical suspicion of cervical spine fracture are often examined with a plain X-ray cervical spine series rather than with cervical spine computed tomography (CT). The authors have been concerned by the absence of fractures in the group of patients examined with plain X-ray. The objective of this investigation was to determine the usefulness of plain X-ray examinations in suspected cases of cervical spine fracture compared to CT. A retrospective review was performed of all trauma patients undergoing imaging for suspected cervical spine fracture in our Emergency Department over a one-year period (January 1, 2007 to December 31, 2007). During the study period, 254 cervical spine plain X-ray and 3,080 cervical spine CT examinations were performed. Of the 254 plain X-ray examinations, 237 were interpreted as negative for fracture, 11 were suboptimal examinations, and six were interpreted as possible fractures (later ruled out by further imaging). Of the 3,080 CT examinations, 2,884 were interpreted as negative for fracture and 196 as positive. The overall positivity rates for acute cervical spine fracture were 0.0% in plain X-ray and 6.4% in CT examinations. These data confirm the authors' concern that plain X-ray imaging for patients with low clinical suspicion for cervical spine trauma in our hospital may have too low a yield to justify its use. However, the 6.4% positivity rate in the group of patients selected for CT examination justifies its use in this group.
- 4 September 2009
- Published by Springer Nature in Emergency Radiology
- Vol. 17 (3) , 191-193
Are cervical spine radiograph examinations useful in patients with low clinical suspicion of cervical spine fracture? An experience with 254 cases
Trauma patients with low clinical suspicion of cervical spine fracture are often examined with a plain X-ray cervical spine series rather than with cervical spine computed tomography (CT). The authors have been concerned by the absence of fractures in the group of patients examined with plain X-ray. The objective of this investigation was to determine the usefulness of plain X-ray examinations in suspected cases of cervical spine fracture compared to CT. A retrospective review was performed of all trauma patients undergoing imaging for suspected cervical spine fracture in our Emergency Department over a one-year period (January 1, 2007 to December 31, 2007). During the study period, 254 cervical spine plain X-ray and 3,080 cervical spine CT examinations were performed. Of the 254 plain X-ray examinations, 237 were interpreted as negative for fracture, 11 were suboptimal examinations, and six were interpreted as possible fractures (later ruled out by further imaging). Of the 3,080 CT examinations, 2,884 were interpreted as negative for fracture and 196 as positive. The overall positivity rates for acute cervical spine fracture were 0.0% in plain X-ray and 6.4% in CT examinations. These data confirm the authors' concern that plain X-ray imaging for patients with low clinical suspicion for cervical spine trauma in our hospital may have too low a yield to justify its use. However, the 6.4% positivity rate in the group of patients selected for CT examination justifies its use in this group.
- 12 May 2005
- Published by Springer Nature in Emergency Radiology
- Vol. 11 (5) , 267-274
Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
Computed tomography (CT) scanning is being increasingly used for evaluation of trauma, which most commonly involves younger individuals. As younger patients are at higher risk for radiation-induced cancer compared to older patients, radiation dose reduction is an important issue in emergency CT scanning. With automatic exposure control techniques, users select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. These techniques can help in reducing radiation dose by 10-60% in most instances. This review article presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of automatic exposure control in emergency CT scanning.
- 12 May 2005
- Published by Springer Nature in Emergency Radiology
- Vol. 11 (5) , 267-274
Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
Computed tomography (CT) scanning is being increasingly used for evaluation of trauma, which most commonly involves younger individuals. As younger patients are at higher risk for radiation-induced cancer compared to older patients, radiation dose reduction is an important issue in emergency CT scanning. With automatic exposure control techniques, users select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. These techniques can help in reducing radiation dose by 10-60% in most instances. This review article presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of automatic exposure control in emergency CT scanning.
- 5 March 2005
- Published by Springer Nature in Emergency Radiology
- Vol. 11 (3) , 127-128
Technologic innovations in computer tomography dose reduction: implications in emergency settings
- 5 March 2005
- Published by Springer Nature in Emergency Radiology
- Vol. 11 (3) , 127-128
Technologic innovations in computer tomography dose reduction: implications in emergency settings