PSPetri Sipola

Petri Sipola

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Petri Sipola has a total of 82 co-authors. Here are the top co-authors by number of shared publications:

  • Ritva Vanninen

    Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland Unit of Radiology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland

    7 shared publications
  • Marja Hedman

    Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland Heart Center, Kuopio University Hospital, Kuopio, Finland

    5 shared publications
  • Pekka Jäkälä

    Unit of Neurology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland NeuroCenter, Kuopio University Hospital, Kuopio, Finland

    5 shared publications
  • Hannu Manninen

    University of Eastern Finland, Faculty of Health Sciences, School of Medicine, Institute of Clinical Medicine, Department of Clinical Radiology, Kuopio, Finland

    4 shared publications
  • Hannu Manninen

    Department of Clinical Radiology, Kuopio University Hospital, Puijonlaaksontie 2, FIN-70210 Kuopio, Finland

    4 shared publications
  • Keijo Peuhkurinen

    4 shared publications

Latest Publications

  • Open Access

    Quantification of Myocardial Blood Flow by Machine Learning Analysis of Modified Dual Bolus MRI Examination

    by Minna Husso, Isaac O. Afara, Mikko J. Nissi, Antti Kuivanen, Paavo Halonen, Miikka Tarkia, Jarmo Teuho, Virva Saunavaara, Pauli Vainio, Petri Sipola, et al.

    Contrast-enhanced magnetic resonance imaging (MRI) is a promising method for estimating myocardial blood flow (MBF). However, it is often affected by noise from imaging artefacts, such as dark rim artefact obscuring relevant features. Machine learning enables extracting important features from such noisy data and is increasingly applied in areas where traditional approaches are limited. In this study, we investigate the capacity of machine learning, particularly support vector machines (SVM) and random forests (RF), for estimating MBF from tissue impulse response signal in an animal model. Domestic pigs (n = 5) were subjected to contrast enhanced first pass MRI (MRI-FP) and the impulse response at different regions of the myocardium (n = 24/pig) were evaluated at rest (n = 120) and stress (n = 96). Reference MBF was then measured using positron emission tomography (PET). Since the impulse response may include artefacts, classification models based on SVM and RF were developed to discriminate noisy signal. In addition, regression models based on SVM, RF and linear regression (for comparison) were developed for estimating MBF from the impulse response at rest and stress. The classification and regression models were trained on data from 4 pigs (n = 168) and tested on 1 pig (n = 48). Models based on SVM and RF outperformed linear regression, with higher correlation (R SVM 2 = 0.81, R RF 2 = 0.74, R linear_regression 2 = 0.60; ρSVM = 0.76, ρRF = 0.76, ρlinear_regression = 0.71) and lower error (RMSESVM = 0.67 mL/g/min, RMSERF = 0.77 mL/g/min, RMSElinear_regression = 0.96 mL/g/min) for predicting MBF from MRI impulse response signal. Classifier based on SVM was optimal for detecting impulse response signals with artefacts (accuracy = 92%). Modified dual bolus MRI signal, combined with machine learning, has potential for accurately estimating MBF at rest and stress states, even from signals with dark rim artefacts. This could provide a protocol for reliable and easy estimation of MBF, although further research is needed to clinically validate the approach.


  • Open Access

    Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference

    by Minna Husso, Mikko J. Nissi, Antti Kuivanen, Paavo Halonen, Miikka Tarkia, Jarmo Teuho, Virva Saunavaara, Pauli Vainio, Petri Sipola, Hannu Manninen, et al.

    The reliable quantification of myocardial blood flow (MBF) with MRI, necessitates the correction of errors in arterial input function (AIF) caused by the T1 saturation effect. The aim of this study was to compare MBF determined by a traditional dual bolus method against a modified dual bolus approach and to evaluate both methods against PET in a porcine model of myocardial ischemia. Local myocardial ischemia was induced in five pigs, which were subsequently examined with contrast enhanced MRI (gadoteric acid) and PET (O-15 water). In the determination of MBF, the initial high concentration AIF was corrected using the ratio of low and high contrast AIF areas, normalized according to the corresponding heart rates. MBF was determined from the MRI, during stress and at rest, using the dual bolus and the modified dual bolus methods in 24 segments of the myocardium (total of 240 segments, five pigs in stress and rest). Due to image artifacts and technical problems 53% of the segments had to be rejected from further analyses. These two estimates were later compared against respective rest and stress PET-based MBF measurements. Values of MBF were determined for 112/240 regions. Correlations for MBF between the modified dual bolus method and PET was rs = 0.84, and between the traditional dual bolus method and PET rs = 0.79. The intraclass correlation was very good (ICC = 0.85) between the modified dual bolus method and PET, but poor between the traditional dual bolus method and PET (ICC = 0.07). The modified dual bolus method showed a better agreement with PET than the traditional dual bolus method. The modified dual bolus method was found to be more reliable than the traditional dual bolus method, especially when there was variation in the heart rate. However, the difference between the MBF values estimated with either of the two MRI-based dual-bolus methods and those estimated with the gold-standard PET method were statistically significant.


  • Open Access

    Effects of knee flexion and extension on the tibial tuberosity–trochlear groove (TT–TG) distance in adolescents

    by Juha‐Sampo Suomalainen, Gideon Regalado, Antti Joukainen, Tommi Kääriäinen, Mervi Könönen, Hannu Manninen, Petri Sipola, Hannu Kokki

    Background: Measurement of the tibial tubercle–trochlear groove (TT–TG) distance is used to assess patellofemoral instability and rotation. Since patellofemoral instability and acute patellar dislocation are common among adolescents, it is important to clarify the relationship between TT–TG distance and various flexion and extension angles in asymptomatic children. The purpose of the present study was to determine how knee flexion and extension influence TT–TG‐distance values measured using 3D imaging in an anatomic axial plane among asymptomatic adolescents.Methods: We performed magnetic resonance imaging (MRI) of 26 knees in 13 adolescents (8 boys and 5 girls) of 11–17 years of age, with no known patellofemoral disorders. Imaging was performed with 3.0 T MRI with the knee at four separate angles of flexion between 0° and 30°. Measurements were made by two independent blinded raters.Results: The mean TT–TG distance in millimetres was 11.1–0.29 × the angle in degrees. TT–TG distance decreased with greater flexion, showing a mean decrease of 0.29 mm (SD, 0.04) per degree of increased flexion (p < 0.001). We found significant inter‐observer (Pearson’s r = 0.636, p = 0.03) and intra‐observer (Pearson’s r = 0.792, p ≤ 0.001) correlations. TT–TG values were not significantly correlated with age, length, weight, or body mass index. The rate of TT–TG change (change between consecutive TT–TG values/change between consecutive angles) was significantly negatively correlated with length (p = 0.014), weight (p = 0.004), and body mass index (p = 0.025).Conclusions: Our data revealed that TT–TG distance assessed in the anatomic axial plane decreased with greater flexion in adolescent. Moreover, this effect of knee angle was stronger in smaller subjects. These findings support the need for a standardized protocol for TT–TG distance measurement in adolescents.


    • 28 August 2016
      • Vol. 30  (5) , 671-6

    Cardiac CT Differentiates Left Atrial Appendage Thrombi from Circulatory Stasis in Acute Stroke Patients.

    by Mikko Taina, Ritva Vanninen, Petri Sipola, Antti Muuronen, Pekka Jäkälä, Marja Hedman

    The left atrial appendage (LAA) is the most typical origin for a cardioembolic thrombusins' stroke etiology. Although transesophageal echocardiography (TEE) is widely used, this technique encounters difficulties in differentiating solid thrombus from circulatory stasis/spontaneous echo contrast (SEC). We assessed whether cardiac computed tomography (cCT) could more accurately detect LAA thrombi. A total of 102 patients with suspected acute cardioembolic stroke/ transient ischemic attack (TIA) without chronic atrial fibrillation underwent arterial and venous phase cCT and TEE. TEE and cCT were consensus read to define LAA thrombus, while TEE alone was used to determine SEC. The LAA/aorta Houndsfield unit (HU) ratio was measured in both phases independently and blinded to prior visual readings. The optimal LAA/aorta HU ratio cut-off value for differentiating thrombi and SEC was estimated. TEE indicated 10 SECs and three thrombi. Consensus reading of cCT and TEE indicated that all thrombi detected in TEE were false-positive but revealed three actual thrombi missed in TEE. The LAA/aorta HU ratio correlated significantly with the presence of SEC both in arterial (p=0.019) and venous phases (p=0.024) and with the presence of thrombi in both phases (p0.245 and 0.245 and <0.824 in the venous phase. Values of sensitivity, specificity, positive and negative predictive value and accuracy for detection of thrombi were 100% for cCT in both phases. cCT is more accurate than TEE in the detection of LAA thrombi, especially when combined with the measurement of LAA/aorta HU ratio.


    • 2 July 2015
      • Vol. 29  (4) , 487-91

    Diagnostic Performance of Left Atrial Diameter Measurement in Computed Tomography to Detect Increased Left Atrial Volume.

    by Mikko Taina, Valtteri Rissanen, Marja Hedman, Pekka Jäkälä, Vesa Järvinen, Ritva Vanninen, Petri Sipola

    The left atrium (LA) is frequently imaged in cardiac computed tomographic (cCT) examinations. The LA volume can be accurately measured with three-dimensional (3D) volumetry but this method is time consuming and thus not routinely used in clinical practice. Accordingly, increased LA size may be overlooked although volume enlargement is associated with adverse cardiovascular events. We evaluated the accuracy of LA diameter measurement in cCT and in transthoracic echocardiography (TTE) in the diagnosis of LA enlargement using 3D cCT as the reference standard. Altogether, 146 patients with suspected cardiogenic stroke underwent cCT and TTE. LA volume by cCT was determined for all patients. LA diameter was measured in both modalities. Furthermore, 40 healthy controls were analyzed in order to assess the cut-off values for normal LA volume. Diagnostic performance of cCT and conventional TTE diametrical measurements for detecting enlarged LA volume were analyzed and compared using Cohen's kappa (κ). In controls, the mean LA volume was 59.8±15.3 ml and the mean LA diameter was 30.4±5.0 mm by cCT. The mean value plus twice the standard deviation, which was considered the upper limit, for normal LA volume and diameter were 90.4 ml and 40.4 mm, respectively. Age- and gender-matched patients with stroke had statistically significantly (p<0.001) larger LA volumes (85.5±21.1 vs. 59.8±15.3 ml) and diameters (37.6±5.7 vs. 30.4±5.0 mm) than controls. LA diameter measurement by cCT was more reliable in detecting an LA volume enlargement than the corresponding measurement with TTE (κ=0.489 vs. 0.234; p=0.002). An enlarged LA diameter measured by cCT was more reliable than TTE at detecting enlarged LA volume.


  • Open Access

    Visually assessed severity of lumbar spinal canal stenosis is paradoxically associated with leg pain and objective walking ability

    by Pekka Kuittinen, Petri Sipola, Tapani Saari, Timo Juhani Aalto, Sanna Sinikallio, Sakari Savolainen, Heikki Kröger, Veli Turunen, Ville Leinonen, Olavi Airaksinen

    Lumbar spinal stenosis (LSS) is the common term used to describe patients with symptoms related to the anatomical reduction of the lumbar spinal canal size. However, some subjects may have a markedly narrowed canal without any symptoms. This raises the question of what is the actual role of central canal stenosis in symptomatic patients. The purpose of this study was to compare radiological evaluations of LSS, both visually and quantitatively, with the clinical findings of patients with LSS. Eighty patients [mean age 63 (11) years, 44% male], with symptoms severe enough to indicate LSS surgery, were included in this prospective single-center study. Lumbar magnetic resonance imaging was performed and one experienced neuroradiologist classified patients into three groups: 0 = normal or mild stenosis, 1 = moderate stenosis, and 2 = severe stenosis. In addition, the same observer measured the minimal dural sac area level by level from the inferior aspect of L1 to the inferior aspect of S1. The association between radiological and clinical findings were tested with Oswestry Disability Index, overall visual analog pain scale, specific low back pain, specific leg pain, Beck Depression Inventory, and walking distance on treadmill exercise test. In the visual classification of the central spinal canal, leg pain was significantly higher and walking distance achieved was shorter among patients with moderate central stenosis than in patients with severe central stenosis (7.33 (2.29) vs 5.80 (2.72); P = 0.008 and 421 (431) m vs 646 (436) m; P = 0.021, respectively). Patients with severe stenosis at only one level also achieved shorter walking distance than patients with severe stenosis of at least two levels. No correlation between visually or quantitatively assessed stenosis and other clinical findings was found. There is no straightforward association between the stenosis of dural sac and patient symptoms or functional capacity. These findings indicated that dural sac stenosis is not the single key element in the pathophysiology of LSS.


  • Computed Tomography and Echocardiography together Reveal More High-Risk Findings than Echocardiography Alone in the Diagnostics of Stroke Etiology

    by Petri Sipola, Marja Hedman, Juha Onatsu, Anu Turpeinen, Matti Halinen, Pekka Jäkälä, Ritva Vanninen

    Background: Cardioembolic stroke carries a major risk of stroke recurrence, which can be markedly reduced by early initiation of appropriate secondary prevention. We investigate whether combined examination of the heart, aorta, and cervicocranial arteries with computed tomography (CACC-CT) may improve the diagnosis of stroke etiology. Methods: Patients with suspected cardiogenic ischemic stroke or transient ischemic attack (n = 140; mean age 60 ± 10 years; 95 males) underwent CACC-CT and standard diagnostics including transthoracic and transesophageal echocardiography (TTE/TEE). Patients with atrial fibrillation were excluded because cardiac imaging will not affect to anticoagulant treatment. Imaging findings with a potential cardioembolic source were analyzed. Aortic and cardiac risk findings were evaluated independently. Consensus reading of 2 experts using the findings of both approaches and complemented by cardiac MRI when needed served as the reference standard. Results: In 101 patients (72%) the clinical diagnosis was stroke, and transient ischemic attack was confirmed in the remaining patients. Imaging findings associated with highly increased cardioembolic risk were detected in 22 patients (16%). Nine high-risk findings in 140 patients were found by TTE/TEE and this number rose to 25 high after performing both echocardiography and CACC-CT. No difference was found between CACC-CT and TTE/TEE in detecting patients with of at least one high-risk findings (sensitivity 68 vs. 41%, p = 0.052; specificity 98 vs. 99%; overall accuracy 94 vs. 90%). Combined use of CACC-CT and TTE/TEE was more sensitive than TTE/TEE alone for detecting patients with at least one cardiac or aortic high-risk finding (sensitivity 91 vs. 41%, p < 0.001; specificity 98 vs. 99%; overall accuracy 97 vs. 90%). TTE/TEE was insufficient for diagnosing myocardial infarction with left ventricular aneurysm, whereas the accuracy of CACC-CT was high. In 9 patients (6%) with normal or mild hypokinesia in TTE/TEE, CACC-CT and MRI showed myocardial infarction large enough to indicate anticoagulant therapy. In contrast, CACC-CT was not suitable for diagnosing small left artrial thrombi, patent foramen ovale or to measure left ventricular ejection fraction. Conclusion: CACC-CT and TTE/TEE alone show limited accuracy for the diagnostics of stroke etiology. Therefore, CACC-CT could be a valuable tool in patients with cryptogenic stroke despite standard stroke diagnostics.


  • Open Access

    Accuracy and reproducibility of a retrospective outcome assessment for lumbar spinal stenosis surgery

    by Pekka Kuittinen, Timo Juhani Aalto, Tapani Heikkilä, Ville Leinonen, Sakari Savolainen, Petri Sipola, Heikki Kröger, Veli Turunen, Olavi Airaksinen

    Retrospective assessment of surgery outcome is considered problematic. The aims of this study were to evaluate the reproducibility and accuracy of a retrospective outcome assessment of lumbar spinal stenosis surgery with reference to prospective outcome scale measurements.


  • A prospective comparison of cardiac magnetic resonance imaging and radionuclide ventriculography in the assessment of cardiac function in patients treated with anthracycline-based chemotherapy

    by Sipola Petri, Vanninen Esko, Jantunen Esa, Nousiainen Tapio, Kiviniemi Mikko, Hartikainen Juha, Kuittinen Taru

    To compare cardiac MRI and radionuclide ventriculography (RVG) in cardiac monitoring during anthracycline (doxorubicin)-based chemotherapy. We studied 10 previously untreated adult non-Hodgkin lymphoma patients. Left ventricular ejection fraction (LVEF) was assessed by MRI and RVG simultaneously. In addition, left ventricular (LV) and left atrial size were determined by MRI. Both MRI and RVG measurements were determined at baseline and then repeated after eight cycles of CHOP chemotherapy (cumulative doxorubicin dose of 400 mg/m2). Power calculations were made on the basis of reproducibility measurements. Clinical heart failure was not observed in any patient during the study. MRI detected a statistically significant increase in LV end-diastolic volume (128±39 vs. 151±46 ml, P<0.05) and LV mass (119±32 vs. 146±49 g, P<0.05) after doxorubicin therapy but no change in LVEF (46±8 vs. 47±11%, P=NS) or left atrial area. A significant LVEF reduction compared with baseline was observed by RVG (61±10 vs. 50±6%, P<0.01). On average, MRI resulted in 7±10% lower LVEF values compared with RVG. RVG seems to be a valuable and repeatable tool in detecting early, subclinical deterioration in cardiac function and is the method of choice in the follow-up of LV function during anthracycline-based chemotherapy. Whether LV volumetric and mass changes found in MRI could predict later significant permanent cardiac damage should be evaluated in larger studies with long-term follow-up.


  • Visual and quantitative assessment of lateral lumbar spinal canal stenosis with magnetic resonance imaging

    by Petri Sipola, Ville Leinonen, Riikka Niemeläinen, Timo Aalto, Ritva Vanninen, Hannu Manninen, Olavi Airaksinen, Michele C Battié

    Background: Lateral lumbar spinal canal stenosis is a common etiology of lumbar radicular symptoms. Quantitative measurements have commonly demonstrated better repeatability than visual assessments. We are not aware of any studies examining the repeatability of quantitative assessment of the lateral canal. Purpose: To evaluate the repeatability of visual assessments and newly developed quantitative measurements of lateral lumbar spinal canal stenosis using magnetic resonance imaging (MRI). Material and Methods: Twenty-eight patients with lateral lumbar spinal canal stenosis or prior spinal surgery with recurrent symptoms were imaged with MRI. A radiologist, a neurosurgeon and a spine research trainee graded visually and quantitatively subarticular ( n = 188) and foraminal zones ( n = 260) of the lateral spinal canal. Quantitative measurements included the minimal subarticular width and the cross-sectional area of the foramen. Results: The repeatability of visual assessment at the subarticular zone and foraminal zones between raters varied from 0.45-0.59 and 0.42-0.53, respectively. Similarly, the intraclass correlation coefficients for the quantitative measurements varied from 0.67-0.71 and 0.66-0.76, respectively. The intra-rater repeatability for the visual assessments of the subarticular and foraminal zones was 0.70 and 0.62, respectively, while the corresponding intraclass correlation coefficients for quantitative measurements were 0.83 and 0.81, respectively. Conclusion: Inter-rater repeatability of visual assessments of lateral stenosis is moderate, whereas quantitative measurements of both subarticular width and the cross-sectional area of the foramen have substantial reproducibility and may be particularly useful for longitudinal studies and research purposes. The clinical value of these parameters requires further study.